Registers refreshed 2026-11-08.See refresh dates
China

MRT Technology (Shenzhen) Co.,

1G, Building A, Junxiangda Building, Zhongshanyuan Road West, Nanshan District, Shenzhen, Guangdong, 518000, People's Republic of China, Shenzhen, Guangdong, China

Visit website
A2LA 3628.02ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
30
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 30 standard numbers and the 15 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI11
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-1
ETSI EN 300 220-3-2
ETSI EN 300 220-4
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 440
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 302 502
IEC 61000 series9
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national

National versions in the same scope

AS/NZS IEC 61000.4.2probably the same standard; matched by number only

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national

National versions in the same scope

AS/NZS IEC 61000.4.4probably the same standard; matched by number only

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+1 national

National versions in the same scope

AS/NZS IEC 61000.4.5probably the same standard; matched by number only

Certificate says EN 61000-4-5. Probably the same standard; not checked against the EN document.

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test+1 national

National versions in the same scope

AS/NZS 61000.4.8probably the same standard; matched by number only

IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
IEC 61000-4-10
IEC 61000-4-12Electromagnetic Compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
IEC 61000-4-18
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
CISPR3
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 22identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national

National versions in the same scope

AS/NZS CISPR 32identical to it

CNS 15936identical to it

VCCI-CISPR 32probably the same standard; matched by number only

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

IEC3
IEC 61204-3
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 62040-2Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
Other standards4
ANSI/TIA-603-E
EN 55103-1
FCC PART 15Radio Frequency Devices
RSS-GEN

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

3628.02

The scope document we hold says it was valid until 2026-10-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 3628.02

LineMethodMatrixRange
147 CFR, FCC Part 15 B (using ANSI C63.4:20142); 47 CFR, FCC Part 18 (using MP-5:1986); CISPR 11; EN 55011; BS EN 55011; CISPR 22; EN 55022; AS/NZS CISPR 22; BS EN 55022; CISPR 32; EN 55032; AS/NZS CISPR 32; BS EN 55032; EN 55103-1; BS EN 55103-1; EN 61204-3; BS EN IEC 61204-3; EN 61326-1; BS EN IEC 61326-1; EN 62040-2; IEC 62040-2; BS EN IEC 62040-2; IEC 61204-3; IEC 61326-1; ICES-003; ICES-005; VCCI-CISPR 32; GB/T 9254; GB 4343.1; CNS 15936:2016; CNS 13438:2006; CNS 13439:2004; CNS 13783-1; J55032; IEC/EN 61000-4-2; AS/NZS IEC 61000.4.2; GB/T 17626.2; BS EN 61000-4-2; IEC/EN 61000-4-4; AS/NZS IEC 61000.4.4; GB/T 17626.4; BS EN 61000-4-4-to 40 GHz
2IEC/EN 61000-4-5; AS/NZS IEC 61000.4.5; GB/T 17626.5; BS EN 61000-4-5; IEC/EN 61000-4-8; AS/NZS 61000.4.8; GB/T 17626.8; BS EN 61000-4-8; IEC/EN 61000-4-9; GB/T 17626.9; BS EN 61000-4-9; IEC/EN 61000-4-10; GB/T 17626.10; BS EN 61000-4-10; IEC/EN 61000-4-12; GB/T 17626.12; BS EN 61000-4-12; IEC/EN 61000-4-18; GB/T 17626.18; BS EN 61000-4-18; IEC/EN 61000-4-29; GB/T 17626.29; BS EN 61000-4-29; EN 300 220-1; EN 300 220-2; EN 300 220-4; EN 300 220-3-1; EN 300 220-3-2; EN 300 330; EN 300 440; EN 300 328; EN 301 893; EN 302 502; EN 301 908-1; 47 CFR, FCC Part 15, Subparts C, E, F; 47 CFR, FCC Part 20; 47 CFR, FCC Part 22 (Subpart H); 47 CFR, FCC Part 24 (Subpart E); 47 CFR, FCC Part 25; 47 CFR, FCC Part 27 (Subparts L & M); 47 CFR, FCC Part 73; 47 CFR, FCC Part 74 (Subparts E, F, & H); 47 CFR, FCC Part 90 (Subparts Y & Z); 47 CFR, FCC Part 95; 47 CFR, FCC Part 97; 47 CFR, FCC Part 101; ANSI C63.10:2013; KDB 905462 D02 (v02); ANSI C63.26:2015; ANSI/TIA 603-E; ANSI/TIA-102.CAAA-E; KDB 905462--
3RSS-GEN; RSS-111; RSS-112; RSS-123; RSS-130; RSS-132; RSS-133; RSS-134; RSS-139; RSS-192; RSS-194; RSS-195; RSS-197; RSS-199; RSS-210; RSS-216; RSS-247; RSS-248; RSS-310; BETS-8; RCR STD-1; RCR STD-33; ARIB STD-T57; ARIB STD-T66; ARIB STD-T67; ARIB STD-T71; ARIB STD-T89; ARIB STD-T91; ARIB STD-T92; ARIB STD-T93; ARIB STD-T96; AS/NZS 4268; LP 0002(2020); ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02)-to 40000 MHz
4ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015-to 40000 MHz
5

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited MRT TECHNOLOGY (SHENZHEN) CO., LTD. Shenzhen, Guangdong, China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 13th day of August 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3628.02 Valid to October 31, 2026 Revised September 27, 2024

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.