Fluke Japan Corporation
Sanki-Yamato Building B 4th Floor 7-10-1, Chuo Rinkan, Yamato-shi, Kanagawa Pref., 242-0007, Japan, Kanagawa Pref., Japan
Visit website- Scope lines
- 29
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 29 scope lines.
A2LA certificate 7747.01 · 29 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSLI Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 2 of 28
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Voltage – Measure
(cont)
0 V
- 0.000 000 01 V
- 0.000 000 1 V
- 0.000 001 V
- 0.000 01 V
- 0.0001 V
± 0.01 V
± 0.1 V
± 1 V
± 10 V
± 100 V
± 120 V
± 500 V
± 1000 V
± 1020 V
± 0.12 V
± 0.121 V
± 1.2 V
± 1.21 V
± 7 V
0.22 µV
0.22 µV
0.22 µV
0.25 µV
1.0 µV
11 µV
19 µV/V
1.1 µV/V
0.4 µV/V
0.3 µV/V
0.6 µV/V
1.5 µV/V
1.5 µV/V
0.9 µV/V
0.9 µV/V
9.2 µV/V
9.0 µV/V
3.2 µV/V
3.0 µV/V
3.0 µV/V
Fluke 8588A
Fluke 8588A
w/ 752A, 732B
Fluke 8588A, Fluke
5730A
Fluke 8588A
Thermocouple Simulation –
Measure 10 mV/ °C
0 °C
100 °C
1000 °C
10 000 °C
0 °C
± 1000 °C
± 5000 °C
± 10 000 °C
0 mV
1 mV
10 mV
100 mV
0 mV
± 10 mV
± 50 mV
± 100 mV
0.43 µV
0.45 µV
0.44 µV
0.72 µV
0.08 µV
0.09 µV
0.12 µV
0.23 µV
HP 3458A, OPT 002
Fluke 8588A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 3 of 28
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Thermocouple Simulation –
Generate 10 mV/ °C
0 mV
100 mV
1 mV/ °C
0 °C
± 1000 °C
± 5000 °C
± 10 000 °C
± 30 000 °C
0 °C
10 000 °C
0 mV
± 10 mV
± 50 mV
± 100 mV
± 300 mV
0.11 °C
0.29 °C
0.39 µV
0.39 µV
0.39 µV
0.39 µV
0.62 µV
Fluke 55XXA
Fluke 57xxA
DC Current – Generate
(1 to 220) μA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 10) A
40 μA/A + 6.0 nA
30 μA/A + 6.0 nA
30 μA/A + 40 nA
70 μA/A + 0.30 μA
80 μA/A + 10 μA
0.040 % + 0.50 mA
3.6 µA/A
5.9 µA/A
13 µA/A
39 µA/A
60 µA/A
Fluke 57X0A
Fluke
57X0A/5725A
Fluke 8508A,
Fluke 742A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 4 of 28
Parameter/Equipment
Range
CMC2, 3, 6 (±)
Comments
DC Current – Measure
(0 to 100) nA
(0.1 to 1) μA
(1 to 10) μA
(10 to 100) μA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 2) A
(2 to 11) A
190 µA
329 µA
1.9 mA
3.29 mA
19 mA
32.9 mA
190 mA
329 mA
1.09 A
2.99 A
10.9 A
20 A
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1A
3.3 % + 50 pA
0.33 % + 30 pA
0.030 % + 30 pA
40 μA/A + 0.8 nA
40 μA/A + 5 nA
40 μA/A + 50 nA
50 μA/A + 0.6 μA
0.010 % + 10 μA
0.020 % + 30 μA
0.040 % + 0.40 mA
3.0 nA
3.6 nA
30 nA
35 nA
0.31 µA
0.39 µA
3.1 µA
4.0 µA
15 µA
44 µA
390 µA
790 µA
6.7 µA/A
10 µA/A
12 µA/A
12 µA/A
HP 3458A
Fluke 8508A
HP 3458A, OPT 002
w/ Fluke 742A-1k
w/ Fluke 742A-100
w/ Fluke 742A-10
HP 3458A, OPT 002
w/ Fluke 742A-1
w/ Guildline 9230
w/ Fluke Y5020
HP3458A, OPT 002
w/ 742A-1k, w/
742A-100, w/ 742A-
10, w/ 742A-1,
w/ Guildline 9230 | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 5 of 28
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Current – Measure
(cont)
0 A
- 0.000 000 000 1 A
- 0.000 000 001 A
- 0.000 000 01 A
- 0.000 000 1 A
- 0.000 001 A
- 0.000 01 A
- 0.0001 A
± 0.000 01 A
± 0.0001 A
± 0.001 A
± 0.01 A
± 0.1 A
± 1 A
± 3.1 A
± 10 A
± 12 A
± 12.1 A
± 20 A
± 30 A
0.29 µA
0.28 µA
0.28 µA
2.8 µA
0.12 µA
0.60 µA
0.75 µA
4.0 µA
13 µA/A
10 µA/A
7.6 µA/A
23 µA/A
24 µA/A
26 µA/A
35 µA/A
73 µA/A
63 µA/A
63 µA/A
26 µA/A
84 µA/A
Fluke 742A-1k
w/Fluke 8588A
Fluke 742A-1k
w/Fluke 8588A
Fluke A40B-10mA
w/Fluke 8588A
Fluke A40B-100mA
w/Fluke 8588A
Fluke A40B-1A
w/Fluke 8588A
Fluke A40B-5A
w/Fluke 8588A
Fluke A40B-20A
w/Fluke 8588A
Fluke A40B-50A
w/Fluke 8588A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 6 of 28
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Resistance –
Generate, Fixed Points
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
90 μΩ
0.17 mΩ
0.23 mΩ
0.43 mΩ
1.1 mΩ
2.0 mΩ
9.3 mΩ
0.017 Ω
0.093 Ω
0.17 Ω
1.1 Ω
2.1 Ω
19
Ω
38 Ω
0.44 kΩ
0.95 kΩ
12 kΩ
Fluke 57X0A
DC Resistance –
Generate
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(0.33 to 32.099 999) kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
(0.33 to 1.099 999) MΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
(1 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
31 µΩ/Ω + 0.78 mΩ
24 µΩ/Ω + 1.2 mΩ
22 µΩ/
Ω + 1.1 mΩ
22 µΩ/Ω + 1.5 mΩ
22 µΩ/Ω + 1.6 mΩ
23 µΩ/Ω + 15 mΩ
23 µΩ/Ω + 16 mΩ
22 µΩ/Ω + 0.16 Ω
23 µΩ/Ω + 0.14 Ω
27 µΩ/Ω + 1.4 Ω
25 µΩ/Ω + 2.0 Ω
50 µΩ/Ω + 21 Ω
0.1 mΩ/Ω + 41 Ω
0.2 mΩ/Ω + 1.9 kΩ
0.4 mΩ/Ω + 2.4 kΩ
2.3 mΩ/Ω + 77 kΩ
12 mΩ/Ω + 0.43 MΩ
0.89 µΩ/Ω + 1.1 µΩ
0.54 µΩ/Ω + 4.6 µΩ
1.0 µΩ/Ω
1.0 µΩ/Ω
2.1 µΩ/Ω
2.4 µΩ/Ω
6.7 µΩ/Ω
14 µΩ/Ω
0.12 mΩ/Ω
Fluke 55XXA
Fluke 742A
Fluke 8508A-7000k
DC Resistance –
Measure
(0.1 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
20 μΩ/Ω + 0.060 mΩ
10 μΩ/Ω + 0.60 mΩ
10 μΩ/Ω + 0.60 mΩ
10 μΩ/Ω + 5.6 mΩ
10 μΩ/Ω + 0.070 Ω
20 μΩ/Ω + 2.3 Ω
60 μΩ/Ω + 120 Ω
0.060 % + 1.1 kΩ
HP 3458A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 7 of 28
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Resistance –
Measure (cont)
Fixed Points
0 Ω
0 Ω
2 Ω
10.9 Ω
11.9 Ω
19 Ω
30 Ω
33 Ω
109 Ω
119 Ω
190 Ω
300 Ω
330 Ω
1.09 kΩ
1.19 kΩ
1.9 kΩ
3 kΩ
3.3 kΩ
10.9 kΩ
11.9 kΩ
19 kΩ
30 kΩ
33 kΩ
109 kΩ
119 kΩ
190 kΩ
300 kΩ
330 kΩ
1.09 MΩ
1.19 MΩ
1.9 MΩ
3 M
Ω
3.3 MΩ
10.9 MΩ
11.9 MΩ
19 MΩ
30 MΩ
33 MΩ
109 MΩ
119 MΩ
290 MΩ
400 MΩ
640 MΩ
1090 MΩ
53 μΩ
53 μΩ
82 μΩ
0.61 mΩ
0.62 mΩ
0.86 mΩ
0.95 mΩ
0.97 mΩ
2.1 mΩ
5.3 mΩ
5.6 mΩ
6 mΩ
6 mΩ
0.015 Ω
0.015 Ω
0.025 Ω
0.032 Ω
0.077 Ω
0.15 Ω
0.53 Ω
0.55 Ω
0.59 Ω
0.92 Ω
1.5 Ω
1.0 Ω
1.1 Ω
0.93 Ω
0.92 Ω
3 Ω
14 Ω
35 Ω
23 Ω
0.15 kΩ
0.17 kΩ
0.13 kΩ
1.3 kΩ
0.52 kΩ
0.53 kΩ
3.3 kΩ
7.1 kΩ
21 kΩ
0.31 MΩ
1.9 MΩ
0.34 MΩ
4 wire short
HP 3458A
HP 3458 w/ 742A-
1M
w/ 742A-10M
HP 3458A w/
Guildline 9334A-
100M | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 8 of 28
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Resistance –
Measure (cont)
Fixed Points
(1 to 1.9) Ω
(1.9 to 10) Ω
(10 to 19) Ω
(19 to 100) Ω
(100 to 190) Ω
190 Ω to 1 kΩ
(1 to 1.9) kΩ
(1.9 to 10) kΩ
(10 to 19) kΩ
(19 to 100) kΩ
(100 to 190) kΩ
190 kΩ to 1 MΩ
(1 to 1.9) MΩ
(1.9 to 10) MΩ
(10 to 19) MΩ
(19 to 100) MΩ
0 Ω
1 Ω
10 Ω
12.1 Ω
100 Ω
121 Ω
1 kΩ
1.21 kΩ
1.90 kΩ
3.00 kΩ
5.00 k
Ω
10.0 kΩ
11.9 kΩ
12.1 kΩ
100 kΩ
121 kΩ
1.00 MΩ
1.21 MΩ
10.0 MΩ
12.1 MΩ
100 MΩ
121 MΩ
300 MΩ
400 MΩ
640 MΩ
1 GΩ
21 μΩ
1.3 μΩ/Ω + 16 μΩ
12 μΩ/Ω + 2 μΩ
0.74 μΩ/Ω + 220 μΩ
5.3 μΩ/Ω
0.37 μΩ/Ω + 930 μΩ
5.3 μΩ/Ω
0.12 μΩ/Ω + 9.8 mΩ
10 μΩ/Ω
0.10 μΩ/Ω + 0.19 Ω
12 μΩ/Ω + 0.020 Ω
0.60 μΩ/Ω + 2.2 Ω
13 μΩ/Ω + 0.3 Ω
80 μΩ/Ω
56 μΩ/Ω + 240 Ω
90 μΩ/Ω
24 μΩ
13 μΩ/Ω
5.6 μΩ/Ω
5.6 μΩ/Ω
4.3 μΩ/Ω
4.3 μΩ/Ω
6.7 μΩ/Ω
6.7 μΩ/Ω
7.3 μΩ/Ω
7.3 μΩ/
Ω
7.1 μΩ/Ω
6.8 μΩ/Ω
6.9 μΩ/Ω
6.9 μΩ/Ω
5.4 μΩ/Ω
7.7 μΩ/Ω
4.9 μΩ/Ω
8.5 μΩ/Ω
5.2 μΩ/Ω
5.2 μΩ/Ω
77 μΩ/Ω
120 μΩ/Ω
510 μΩ/Ω
420 μΩ/Ω
520 μΩ/Ω
620 μΩ/Ω
Fluke 8508A
w/ 742A
w/ Guildline
9334A-100M
742A-100
w/Fluke 8588A
w/57xxA
742A-1k
w/Fluke 8588A
w/57xxA
742A-10k
w/Fluke 8588A
w/57xxA
742A-100k
w/Fluke 8588A
w/57xxA
742A-1M
w/Fluke 8588A
w/57xxA
742A-10M
w/Fluke 8588A
w/57xxA
Fluke SL984
w/Fluke 8588A
w/57xxA | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 9 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Generate
(0.2 to 2.2) mV
(2.2 to 22) mV
(22 to 220) mV
220 mV to 2.2 V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
0.010 % + 5.0 μV
0.020 % + 4.0 μV
60 μV/V + 4.0 μV
0.020 % + 4.0 μV
0.030 % + 6.0 μV
0.11 % + 10 μV
0.11 % + 20 μV
0.22 % + 20 μV
0.060 % + 4.0 μV
0.040 % + 4.0 μV
0.030 % + 4.0 μV
0.020 % + 4.0 μV
0.080 % + 5.0 μV
0.14 % + 10 μV
0.14 % + 20 μV
0.27 % + 20 μV
0.030 % + 10 μV
0.020 % + 10 μV
90 μV/V + 7.0 μV
0.020 % + 7.0 μV
0.050 % + 20
μV
0.090 % + 20 μV
0.13 % + 30 μV
0.26 % + 50 μV
0.030 % + 40 μV
0.020 % + 40 μV
90 μV/V + 20 μV
70 μV/V + 10 μV
0.010 % + 30 μV
0.040 % + 80 μV
0.10 % + 200 μV
0.15 % + 400 μV
Fluke 57X0A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 10 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage
– Generate
(cont)
(2.2 to 22) V
(22 to 220) V
(220 to 700) V
(700 1100) V
(0.1 to 1) V
(1 to 10) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(15 to 50) Hz
50 Hz to 1 kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
(20 to 55) Hz
55 Hz to 1 kHz
(1 to 3) kHz
(3 to 10) kHz
(10 to 30) kHz
(30 to 60) kHz
(60 to 100) kHz
(20 to 55) Hz
55 Hz to 1 kHz
(1 to 3) kHz
(3 to 10) kHz
(10 to 30) kHz
(30 to 60) kHz
(60 to 100) kHz
(100 to 500) kHz
500 kHz to 1 MHz
0.030 % + 0.40 mV
0.020 % + 0.40 mV
90 μV/V + 0.20 mV
70 μV/V + 90 μV
0.010 % + 0.20 mV
0.030 % + 0.60 mV
0.090 % + 0.90 mV
0.14 % + 3.1 mV
0.030 % + 3.5 mV
0.020 % + 3.8 mV
90 μV/V + 1.5 mV
80 μV/V + 0.90 mV
0.14 % + 1.6 mV
0.090 % + 15 mV
90 μV/V + 1.6 mV
80 μV/V
0.010 % + 0.30 mV
0.020 % + 3.3 mV
0.060 % + 10 mV
29 µV/V + 1 µV
23 µV/V + 2 µV
24 µV/V + 1 µV
30 µV/V
36 µV/V + 4 µV
58 µV/V + 10 µV
74 µV/V + 9 µV
31 µV/V
26 µV/V
31 µV/V
30 µV/V
57 µV/V
0.10 mV/V
0.17 mV/V
2.9 mV/V
4.5 mV/V
Fluke 57X0A
Fluke
57X0A/5725A
Fluke 792A,
Fluke 5790A/B,
Fluke 5730A
Fluke 792A,
Fluke 5790A/B,
Fluke 5730A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 11 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage
– Generate
(cont)
(10 to 100) V
(100 to 500) V
(500 to 1000) V
(20 to 55) Hz
55 Hz to 1 kHz
(1 to 3) kHz
(3 to 10) kHz
(10 to 30) kHz
(30 to 60) kHz
(60 to 100) kHz
50 Hz to 1 kHz
(1 to 3) kHz
(3 to 10) kHz
(10 to 30) kHz
(1 to 30) kHz
39 µV/V
25 µV/V + 11 µV
29 µV/V + 11 µV
30 µV/V
72 µV
0.11 mV/V
0.10 mV/V
39 µV/V
38 µV/V
43 µV/V
73 µV/V
2 µV/V + 17 mV
Fluke 792A,
Fluke 5790A/B,
Fluke 5730A
AC Voltage – Measure
220 μV to 10 mV
(10 to 100) mV
(0.1 to 1) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
0.030 % + 4.0 μV
0.020 % + 3.0 μV
0.030 % + 3.0 μV
0.10 % + 3.0 μV
0.60 % + 2.0 μV
4.6 % + 3.0 μV
70 μV/V + 50 μV
0.010 % + 9.0 μV
0.010 % + 9.0 μV
0.030 % + 8.0 μV
0.090 % + 5.0 μV
0.35 % + 10 μV
1.2 % + 30 μV
70 μV/V + 60 μV
70 μV/V + 40 μV
0.020 % + 40 μV
0.030 % + 40 μV
0.090 % + 30 μV
0.35 % + 100 μV
1.2 % + 300 μV
HP 3458A | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 12 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Measure
(cont)
(1 to 10) V
(10 to 100) V
(100 to 700) V
(700 to 1000) V
3 mV
30 mV
33 mV
300 mV
0.33 V
3 V
3 V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
40 Hz to 1 kHz
40 Hz to 10 kHz
(10 to 30) kHz
(50 to 60) Hz
10 Hz
50 Hz
60 Hz to 20 kHz
50 kHz
100 kHz
450 kHz
1 kHz
10 Hz
50 Hz
60 Hz
1 kHz
10 kHz
20 kHz
50 kHz
100 kHz
500 kHz
1 kHz
10 Hz
50 Hz
60 Hz
1 kHz
10 kHz
20 kHz
50 kHz
100 kHz
450 kHz
70 μV/V + 0.70 mV
60 μV/V + 0.60 mV
0.010 % + 0.60 mV
0.030 % + 0.50 mV
0.090 % + 0.40 mV
0.35 % + 1.3 mV
1.2 % + 5.6 mV
0.020 % + 5.7 mV
0.020 % + 3.8 mV
0.020 % + 3.8 mV
0.040 % + 3.4 mV
0.14 % + 3.3 mV
0.050 % + 30 mV
0.030 % + 24 mV
0.020 % + 57 mV
2 µV
9.1 µV
3.7 µV
3.6 µV
6.1 µV
0.11 mV
30 µV
3.9 µV
68 µV
20 µV
12 µV
18 µV
19 µV
12 µV
18 µV
28 µV
0.11 mV
18 µV
0.93 mV
0.14 mV
0.12 mV
0.10 mV
0.19 mV
85 µV
0.15 mV
0.25 mV
1.2 mV
HP 3458A
Fluke 8508A
Fluke 5790B | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 13 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Measure
(cont)
3.3 V
30 V
33 V
300 V
330 V
1000 V
10 mV
300 mV
3 V
5 V
1 kHz
10 Hz
50 Hz
60 Hz
(1 to 10) kHz
20 kHz
50 kHz
90 kHz
1 kHz
50 Hz
60 Hz
(1 to 18) kHz
50 kHz
80 kHz
1 kHz
(50 to 60) Hz
1 kHz
5 kHz
8 kHz
50 Hz
60 Hz
1 kHz
5 kHz
10 kHz
30 kHz
10 Hz
45 Hz
50 Hz
60 Hz
1 kHz
5 kHz
10 kHz
30 kHz
10 Hz
45 Hz
50 Hz
60 Hz
1 kHz
5 kHz
10 kHz
30 kHz
10 Hz
45 Hz
50 Hz
60 Hz
1 kHz
5 kHz
10 kHz
0.35 mV
6.1 mV
1.0 mV
1.1 mV
1.0 mV
1.1 mV
1.8 mV
2.9 mV
2.5 mV
14 mV
15 mV
14 mV
40 mV
0.15 V
16 mV
44 mV
48 mV
43 mV
44 mV
12 µV
2.2 µV
2.9 µV
3.4 µV
2.8 µV
2.6 µV
64 µV
12 µV
15 µV
12 µV
18 µV
12 µV
19 µV
18 µV
0.93 mV
0.11 mV
0.15 mV
0.14 mV
0.11 mV
0.10 mV
0.20 mV
0.16 mV
50 mV
0.35 mV
0.31 mV
0.28 mV
0.22 mV
0.19 mV
1.1 mV
Fluke 5790B | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 14 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Measure
(cont)
(2 to 20) mV
(20 to 200) mV
(0.2 to 2) V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
10 Hz
50 Hz
60 Hz
400 Hz to 20 kHz
50 kHz
100 kHz
300 kHz
1 MHz
10 Hz
50 Hz
60 Hz
400 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
1 MHz
10 Hz
50 Hz
60 Hz
400 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
1 MHz
10 Hz
50 Hz
60 Hz
400 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
1 MHz
10 Hz
50 Hz
60 Hz
400 Hz
1 kHz
20 kHz
50 kHz
100 kHz
50 Hz
60 Hz
400 Hz
1 kHz
120 µV/V + 3.5 µV
61 µV/V + 1.7 µV
67 µV/V + 1.6 µV
61 µV/V + 1.6 µV
120 µV/V + 2.6 µV
180 µV/V + 3.5 µV
520 µV/V + 5.7 µV
1200 µV/V + 10 µV
170 µV/V + 2.4 µV
45 µV/V + 2.0 µV
31 µV/V + 2.3 µV
27 µV/V + 2.4 µV
26 µV/V + 2.4 µV
27 µV/V + 2.3 µV
45 µV/V + 4.0 µV
120 µV/V + 4.6 µV
160 µV/V + 13 µV
760 µV/V + 19 µV
800 µV/V
41 µV/V + 2.9 µV
21 µV/V + 4.2 µV
19 µV/V + 4.0 µV
17 µV/V + 5.0 µV
18 µV/V + 4.1 µV
34 µV/V + 6.2 µV
51 µV/V + 18 µV
120 µV/V + 21 µV
740 µV/V + 22 µV
800 µV/V
22 µV/V + 40 µV
32 µV/V
24 µV/V
24 µV/V
23 µV/V
39 µV/V
65 µV/V
150 µV/V
950 µV/V
1100 µV/V + 14 000 µV
41 µV/V
34 µV/V
27 µV/V
27 µV/V
23 µV/V
55 µV/V
80 µV/V
39 µV/V + 380 µV
57 µV/V
34 µV/V
34 µV/V
Fluke 5790B | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 15 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Measure
(cont)
0.001 V
0.01 V
0.0121 V
0.1 V
0.12 V
0.121 V
3 Hz
5 Hz
10 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
3 Hz
5 Hz
10 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
3 Hz
5 Hz
10 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
3 Hz
5 Hz
10 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
45 Hz
65 Hz
3 Hz
5 Hz
10 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
1400 µV/V
1400 µV/V
1400 µV/V
1300 µV/V
1300 µV/V
1300 µV/V
2200 µV/V
2900 µV/V
4900 µV/V
8100 µV/V
42 µV/V
44 µV/V
47 µV/V
190 µV/V
190 µV/V
190 µV/V
320 µV/V
430 µV/V
940 µV/V
1300 µV/V
42 µV/V
44 µV/V
47 µV/V
170 µV/V
170 µV/V
170 µV/V
290 µV/V
400 µV/V
880 µV/V
1200 µV/V
32 µV/V
34 µV/V
37 µV/V
41 µV/V
41 µV/V
41 µV/V
69 µV/V
140 µV/V
220 µV/V
360 µV/V
39 µV/V
39 µV/V
32 µV/V
34 µV/V
37 µV/V
40 µV/V
39 µV/V
39 µV/V
66 µV/V
140 µV/V
220 µV/V
350 µV/V
Fluke 8588A
7
Fluke 5790B
Fluke 8588A
7
Fluke 5790B
Fluke 8588A
7
Fluke 5790B
Fluke 8588A
7
Fluke 5790B
Fluke 5790B
Fluke 8588A
7
Fluke 5790B | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 16 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Measure
(cont)
1 V
1.2 V
1.21 V
3.3 V
5 V
10 V
12.1 V
3 Hz
5 Hz
10 Hz
40 Hz
40.01 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
45 Hz
400 Hz
1 kHz
5 kHz
3 Hz
5 Hz
10 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
10 kHz
45 Hz
400 Hz
1 kHz
5 kHz
10 kHz
3 Hz
5 Hz
10 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
3 Hz
5 Hz
10 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
27 µV/V
27 µV/V
28 µV/V
19 µV/V
19 µV/V
19 µV/V
19 µV/V
36 µV/V
55 µV/V
130 µV/V
280 µV/V
19 µV/V
21 µV/V
19 µV/V
19 µV/V
27 µV/V
27 µV/V
28 µV/V
25 µV/V
19 µV/V
19 µV/V
36 µV/V
55 µV/V
120 µV/V
200 µV/V
37 µV/V
19 µV/V
19 µV/V
19 µV/V
19 µV/V
19 µV/V
27 µV/V
27 µV/V
28 µV/V
22 µV/V
21 µV/V
21 µV/V
37 µV/V
63 µV/V
160 µV/V
310 µV/V
27 µV/V
27 µV/V
28 µV/V
24 µV/V
21 µV/V
21 µV/V
37 µV/V
63 µV/V
150 µV/V
Fluke 8588A
7
Fluke 5790B
Fluke 5790B
Fluke 8588A
7
Fluke 5790B
Fluke 5790B
Fluke 8588A
7
Fluke 5790B
Fluke 8588A
7
Fluke 5790B | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 17 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Measure
(cont)
100 V
121 V
330 V
331 V
1000 V
1020 V
3 Hz
5 Hz
10 Hz
40 Hz
40.01 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
3 Hz
5 Hz
10 Hz
40 Hz
1 kHz
10 kHz
10.01 kHz
20 kHz
50 kHz
100 kHz
3 Hz
5 Hz
10 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
3 Hz
5 Hz
10 Hz
40 Hz
1 kHz
10 kHz
40 Hz
1 kHz
10 kHz
27 µV/V
27 µV/V
28 µV/V
24 µV/V
24 µV/V
24 µV/V
24 µV/V
54 µV/V
76 µV/V
160 µV/V
27 µV/V
27 µV/V
28 µV/V
29 µV/V
24 µV/V
24 µV/V
24 µV/V
24 µV/V
54 µV/V
76 µV/V
27 µV/V
27 µV/V
28 µV/V
33 µV/V
32 µV/V
32 µV/V
100 µV/V
390 µV/V
26 µV/V
26 µV/V
27 µV/V
32 µV/V
32 µV/V
32 µV/V
29 µV/V
30 µV/V
30 µV/V
Fluke 8588A
7
Fluke 5790B
Fluke 8588A
7
Fluke 5790B
Fluke 8588A
7
Fluke 5790B
Fluke 8588A
7
Fluke 5790B
Fluke 5790B | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 18 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current – Generate
(0 to 0.22) mA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(0.3 to 1) kHz
(1 to 3) kHz
(3 to 5) kHz
(5 to 10) kHz
(0.3 to 1) kHz
(1 to 3) kHz
(3 to 5) kHz
(5 to 10) kHz
(0.3 to 1) kHz
(1 to 3) kHz
(3 to 5) kHz
(5 to 10) kHz
(0.3 to 1) kHz
(1 to 3) kHz
(3 to 5) kHz
(5 to 10) kHz
0.020 % + 20 nA
0.020 % + 20 nA
0.010 % + 20 nA
0.020 % + 20 nA
1.0 % + 60 nA
0.020 % + 40 nA
0.020 % + 40 nA
0.020 % + 30 nA
0.020 % + 100 nA
0.10 % + 600 nA
0.020 % + 200 nA
0.020 % + 200 nA
0.020 % + 100 nA
0.020 % + 300 nA
0.090 % + 3.0 μA
0.020 % + 2.0 μ
A
0.020 % + 4.0 μA
0.020 % + 3.0 μA
0.020 % + 3.0 μA
0.10 % + 10 μA
0.030 % + 30 μA
0.050 % + 80 μA
0.72 % + 0.20 mA
0.05 % + 0.20 mA
0.10 % + 0.30 mA
0.36 % + 1.3 mA
0.12 mA/A + 5.6 nA
0.13 mA/A + 0.11 µA
0.13 mA/A
0.12 mA/A
18 µA/A + 0.11 µA
18 µA/A + 0.11 µA
20 µA/A + 0.11 µA
20 µA/A + 0.11 µA
39 µA/A
40 µA/A
41 µA/A
41 µA/A
60 µA/A
60 µA/A
42 µA/A
42 µA/A
Fluke 57X0A
Fluke
57X0A/5725A
Metal film resistor
Fluke 5790A/B
Fluke 5730A
Shunt:
A40B-10 mA
A40B-1 A
A40B-20 A | ||
| 19 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 19 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current – Generate
(cont)
(1 to 10) A
(0.3 to 1) kHz
(1 to 3) kHz
(3 to 5) kHz
(5 to 10) kHz
82 µA/A
0.12 mA/A
0.21 mA/A
0.64 mA/A
Shunt:
A40B-10 mA
A40B-1 A
A40B-20 A
AC Current – Measure
(10 to 100) μA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 2) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 1) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.46 % + 0.040 μA
0.17 % + 0.040 μA
0.070 % + 0.040 μA
0.070 % + 0.040 μA
0.46 % + 0.30 μA
0.17 % + 0.30 μA
0.060 % + 0.40 μA
0.030 % + 0.40 μA
0.46 % + 3.0 μA
0.16 % + 4.0 μA
0.050 % + 5.0 μA
0.020 % + 5.0 μA
0.46 % + 30 μA
0.16 % + 40 μA
0.060 % + 40 μA
0.020 % + 40
μA
0.45 % + 400 μA
0.15 % + 700 μA
0.060 % + 800 μA
0.090 % + 700 μA
0.060 % + 0.20 mA
0.080 % + 0.20 mA
HP 3458A | 1 to 10 A |
| 20 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 20 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current – Measure
(cont)
(2 to 11) A
33 µA
329 µA
0.33 mA
3.29 mA
3.3 mA
32.9 mA
33 mA
329 mA
0.33 A
10 Hz to 2 kHz
(2 to 10) kHz
(1 to 10) kHz
10 Hz
45 Hz
50 Hz
60 Hz to 30 kHz
(1 to 5) kHz
10 Hz
45 Hz
50 Hz
60 Hz to 10 kHz
30 kHz
(1 to 5) kHz
10 Hz
45 Hz to 10 kHz
30 kHz
1 kHz
5 kHz
30 kHz
10 Hz
45 Hz
(50 to 60) Hz
(1 to 10) kHz
30 kHz
1 kHz
(5 to 10) kHz
0.080 % + 2.0 mA
0.26 % + 2.0 mA
0.036 µA
0.13 µA
0.11 µA
0.16 µA
0.11 µA
0.13 µA
0.97 µA
0.64 µA
0.65 µA
0.64 µA
0.66 µA
0.92 µA
9.5 µA
6.2 µA
6.8 µA
9.1 µA
9.2 µA
9.3 µA
0.11 mA
0.069 mA
0.070 mA
0.069 mA
0.087 mA
0.17 mA
0.16 mA
Fluke 8508A
Fluke 5522A,
5790B w/ 1 kΩ
metal film resistor | 2 to 11 A |
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 21 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current – Measure
(cont)
2.99 A
3.3 A
10 A
20 A
190 µA to 1.9 mA
(1.9 to 19) mA
(19 to 190) mA
190 mA to 1.9 A
10 µA
100 µA
50 Hz to 5 kHz
500 Hz
5 kHz
(50 to 60) Hz
1 kHz
5 kHz
50 Hz to 1 kHz
5 kHz
50 Hz
60 Hz
400 Hz to 10 kHz
50 Hz
60 Hz
400 Hz to 5 kHz
10 kHz
50 Hz
60 Hz
400 Hz to 5 kHz
10 kHz
50 Hz to 60 Hz
400 Hz to 1 kHz
5 kHz
10 kHz
3 Hz
45 Hz
1 kHz
5 kHz
10 kHz
30 kHz
3 Hz
10 Hz
45 Hz
1 kHz
5 kHz
10 kHz
30 kHz
0.0017 A
0.0031 A
0.0032 A
0.0080 A
0.0083 A
0.011 A
0.030 A
0.034 A
130 µA/A + 0.0013 µA
130 µA/A + 0.0023 µA
110 µA/A + 0.0051 µA
130 µA/A
130 µA/A
120 µA/A
110 µA/A + 0.010 µA
120 µA/A + 0.20 µA
130 µA/A + 0.11 µA
120 µA/A + 0.20 µA
120 µA/A + 0.20 µA
160 µA/A
160 µA/A
190 µA/A
530 µA/A
86 µA/A
270 µA/A
230 µA/A
230 µA/A
230 µA/A
530 µA/A
53 µA/A
57 µA/A
63 µA/A
63 µA/A
63 µA/A
67 µA/A
110 µA/A
Fluke 5790B, AC
shunts
Fluke A40B-
1mA
w/Fluke 5790B
w/Fluke 8588A | ||
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 22 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current – Measure
(cont)
121 µA
1 mA
1.21 mA
10 mA
12.1 mA
100 mA
121 mA
3 Hz
45 Hz
1 kHz
5 kHz
10 kHz
30 kHz
3 Hz
10 Hz
45 Hz
1 kHz
5 kHz
10 kHz
30 kHz
3 Hz
45 Hz
1 kHz
5 kHz
10 kHz
30 kHz
3 Hz
10 Hz
45 Hz
1 kHz
5 kHz
10 kHz
30 kHz
3 Hz
45 Hz
1 kHz
5 kHz
10 kHz
30 kHz
3 Hz
10 Hz
45 Hz
1 kHz
5 kHz
10 kHz
30 kHz
3 Hz
45 Hz
1 kHz
5 kHz
10 kHz
30 kHz
53 µA/A
60 µA/A
62 µA/A
62 µA/A
64 µA/A
91 µA/A
50 µA/A
51 µA/A
46 µA/A
49 µA/A
49 µA/A
51 µA/A
67 µA/A
41 µA/A
49 µA/A
52 µA/A
52 µA/A
54 µA/A
82 µA/A
37 µA/A
38 µA/A
31 µA/A
35 µA/A
36 µA/A
39 µA/A
56 µA/A
38 µA/A
32 µA/A
36 µA/A
36 µA/A
39 µA/A
56 µA/A
37 µA/A
38 µA/A
31 µA/A
35 µA/A
36 µA/A
39 µA/A
56 µA/A
38 µA/A
32 µA/A
35 µA/A
36 µA/A
39 µA/A
57 µA/A
Fluke A40B-
1mA
w/Fluke 5790B
w/Fluke 8588A
Fluke A40B-
10mA
w/Fluke 5790B
w/Fluke 8588A
Fluke A40B-
100mA
w/Fluke 5790B
w/Fluke 8588A | ||
| 23 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 23 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current – Measure
(cont)
1 A
1.21 A
3.1 A
3.11 A
10 A
12.1 A
20 A
30 A
3 Hz
10 Hz
45 Hz
1 kHz
5 kHz
10 kHz
30 kHz
3 Hz
45 Hz
1 kHz
5 kHz
10 kHz
3 Hz
10 Hz
45 Hz
1 kHz
5 kHz
10 kHz
3 Hz
45 Hz
1 kHz
5 kHz
10 kHz
3 Hz
10 Hz
45 Hz
1 kHz
5 kHz
10 kHz
3 Hz
45 Hz
1 kHz
5 kHz
3 Hz
10 Hz
45 Hz
1 kHz
5 kHz
3 Hz
10 Hz
45 Hz
1 kHz
5 kHz
40 µA/A
40 µA/A
34 µA/A
36 µA/A
41 µA/A
67 µA/A
83 µA/A
42 µA/A
41 µA/A
43 µA/A
47 µA/A
71 µA/A
47 µA/A
48 µA/A
47 µA/A
49 µA/A
59 µA/A
75 µA/A
47 µA/A
48 µA/A
53 µA/A
59 µA/A
75 µA/A
82 µA/A
82 µA/A
82 µA/A
85 µA/A
100 µA/A
150 µA/A
74 µA/A
74 µA/A
78 µA/A
94 µA/A
47 µA/A
48 µA/A
47 µA/A
66 µA/A
160 µA/A
93 µA/A
94 µA/A
93 µA/A
110 µA/A
180 µA/A
Fluke A40B-1A
w/Fluke 5790B
w/Fluke 8588A
Fluke A40B-5A
w/Fluke 5790B
w/Fluke 8588A
Fluke A40B-20A
w/Fluke 5790B
w/Fluke 8588A
Fluke A40B-50A
w/Fluke 5790B
w/Fluke 8588A | ||
| 24 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 24 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage Phase – Measure
3 V / (0 ± 10) °
3 V / (60 ± 10) °
3 V / (90 ± 10) °
30 V / (90 ± 10) °
50 V / (90 ± 10) °
10V, 5V / (0 ± 10) °
10V, 5V / (30 ± 10) °
10V, 5V / (45 ± 10) °
10V, 5V / (60 ± 10) °
10V, 5V / (90 ± 10) °
10V, 5V / (180 ± 10) °
10V, 5V / (270 ± 10) °
65 Hz to 1 kHz
5 kHz
10 kHz
30 kHz
60 Hz
400 Hz
1 kHz
5 kHz
10 kHz
30 kHz
(60 to 65) Hz
400 Hz
1 kHz
5 kHz
10 kHz
30 kHz
65 Hz
65 Hz
65 Hz
65 Hz
65 Hz
65 Hz
65 Hz
65 Hz
65 Hz
0.022 °
0.048 °
0.056 °
0.063 °
0.026 °
0.027 °
0.025 °
0.048 °
0.054 °
0.063 °
0.022 °
0.027 °
0.027 °
0.048 °
0.058 °
0.067 °
0.022 °
0.035 °
0.023 °
0.023 °
0.023 °
0.023 °
0.023 °
0.023 °
0.023 °
Clarke-Hess 6000A
AC Current Phase – Measure
300 mA / (0 ± 10) °
2 A / (0 ± 10) °
5 A / (0 ± 10) °
300 mA / (60 ± 10) °
2 A / (60 ± 10) °
20 A / (60 ± 10) °
20 A / (60 ± 10) °
300 mA / (90 ± 10) °
2 A / (90 ± 10) °
20 A / (90 ± 10) °
20 A / (90 ± 10) °
65 Hz
1 kHz
30 kHz
65 Hz
65 Hz
400 Hz
65 Hz
0.025 °
0.027 °
0.066 °
0.024 °
0.030 °
0.035 °
0.027 °
0.026 °
0.025 °
0.032 °
0.031 °
0.025 °
0.041 °
0.041 °
For 300 mA & 2A;
A40, 6000 A
For 5 A & 20 A;
Y5020, 6000 A | ||
| 25 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 25 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current Phase – Measure
(cont)
10 V, 0.1 A / (0 ± 10) °
10 V, 0.1 A / (30 ± 10) °
10 V, 0.1 A / (45 ± 10) °
10 V, 0.1 A / (60 ± 10) °
10 V, 0.1 A / (90 ± 10) °
10 V, 0.1 A / (180 ± 10) °
10 V, 0.1 A / (270 ± 10) °
10 V, 0.1 A / (90 ± 10) °
10 V, 0.1 A / (90 ± 10) °
10 V, 0.1 A / (90 ± 10) °
10 V, 0.1 A / (90 ± 10) °
10 V, 0.1 A / (90 ± 10) °
10 V, 3.11 A / (0 ± 10) °
10 V, 3.11 A / (0 ± 10) °
1 V, 12.1 A / (180 ± 10) °
10 V, 12.1 A / (30 ± 10) °
1.2 V, 20 A / (0 ± 10) °
10 V, 20 A / (90 ± 10) °
250 V, 0.1 A / (90 ± 10) °
250 V, 0.1 A / (0 ± 10) °
250 V, 0.1 A / (45 ± 10) °
65 Hz
65 Hz
65 Hz
65 Hz
65 Hz
65 Hz
65 Hz
400 Hz
1000 Hz
5000 Hz
10 000 Hz
30 000 Hz
65 Hz
400 Hz
65 Hz
65 Hz
65 Hz
400 Hz
65 Hz
10 000 Hz
30 000 Hz
0.027 °
0.027 °
0.027 °
0.027 °
0.027 °
0.027 °
0.027 °
0.034 °
0.036 °
0.049 °
0.064 °
0.079 °
0.027 °
0.034 °
0.027 °
0.027 °
0.027 °
0.034 °
0.027 °
0.064 °
0.079 °
Clarke-Hess 6000A
w/A40B
AC Capacitance – Measure
0.22 nF
0.35 nF
0.48 nF
0.6 nF
1 nF
2 nF
7 nF
10.9 nF
20 nF
70 nF
109 nF
200 nF
300 nF
0.7 µF
1.09 µF
2 µF
3 µF
7 µF
10.9 µF
20 µF
30 µF
70 µF
109 µF
5 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
100 Hz
100 Hz
100 Hz
100 Hz
100 Hz
100 Hz
100 Hz
100 Hz
50 Hz
50 Hz
0.46 pF
0.39 pF
0.46 pF
0.48 pF
0.63 pF
1.2 pF
3.8 pF
6.6 pF
11 pF
39 pF
66 pF
0.11 nF
0.17 nF
0.40 nF
0.78 nF
1.2 nF
1.7 nF
3.9 nF
6.9 nF
12 nF
16 nF
41 nF
68 nF
Hioki IM3533 | ||
| 26 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 26 of 28
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Capacitance –
Measure (cont)
0.2 nF
1 nF
1.21 nF
10 nF
12.1 nF
20 nF
30 nF
50 nF
100 nF
120 nF
121 nF
1 µF
1.21 µF
10 µF
12.1 µF
100 µF
121 µF
1000 Hz
1000 Hz
1000 Hz
1000 Hz
610 Hz
610 Hz
610 Hz
610 Hz
610 Hz
610 Hz
100 Hz
100 Hz
80 Hz
80 Hz
20 Hz
20 Hz
5 Hz
1500 µF/F
610 µF/F
610 µF/F
500 µF/F
500 µF/F
500 µF/F
500 µF/F
500 µF/F
500 µF/F
500 µF/F
500 µF/F
500 µF/F
500 µF/F
500 µF/F
500 µF/F
500 µF/F
500 µF/F
Hioki IM3533
AC Inductance –
Measure
15 µH
100 µH
121 µH
1 mH
1.21 mH
2 mH
3 mH
5 mH
10 mH
12 mH
12.1 mH
100 mH
121 mH
1 H
1.21 H
10 H
12.1 H
100 H
1 kHz
1 kHz
1 kHz
1 kHz
110 Hz
110 Hz
110 Hz
110 Hz
110 Hz
110 Hz
100 Hz
100 Hz
10 Hz
10 Hz
3 Hz
3 Hz
2 Hz
2 Hz
1500 µH/H
760 µH/H
760 µH/H
550 µH/H
550 µH/H
550 µH/H
550 µH/H
550 µH/H
550 µH/H
550 µH/H
550 µH/H
510 µH/H
550 µH/H
510 µH/H
550 µH/H
500 µH/H
500 µH/H
500 µH/H
Hioki IM3533 | ||
| 27 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 27 of 28
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Capacitance – Measure
200 µF
300 µF
1 mF
3 mF
10 mF
30 mF
50 mF
100 mF
1 mF
1.21mF
10 mF
12.1mF
100 mF
0.098 µF
0.11 µF
0.24 µF
0.45 µF
1.1 µF
3.4 µF
5 µF
9 µF
160 µF/F
140 µF/F
130 µF/F
130 µF/F
140 µF/F
HP 3458A, 5522A
Fluke 5730A
w/8588A
II. Mechanical
Parameter/Equipment
Range
CMC
2, 5 (±)
Comments
Gauge Pressure –
Measuring Equipment
(Pneumatic)
(-90 to 0) kPa
(0 to 100) kPa
(100 to 200) kPa
(200 to 700) kPa
(700 to 2000) kPa
0.041 kPa
0.024 kPa
0.033 kPa
0.14 kPa
0.26 kPa
Fluke PM500
w/ BG100K
w/ BG200K
w/ BG700K
w/ BG2M; 6270A
III. Thermodynamics
Parameter/Equipment
Range
CMC
2, 5 (±)
Comments
Cold Junction
Compensation
(22 to 24) °C
0.031 °C
Super-thermometer
(1504A) /PRT
reference
thermometer, liquid
baths & dry wells | ||
| 28 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7747.01) 12/11/2025 Page 28 of 28
IV. Time & Frequency
Parameter/Equipment
Frequency
CMC
2, 5 (±)
Comments
Frequency – Measure
10 MHz
10 Hz to 1 MHz
1.9 nHz/Hz
1.9 nHz/Hz + 0.6 R
FCA3103 w/ GPS
FCA31xx w/o GPS, R
= Resolution
___________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Ca pability Uncertainty (CMC) is the smallest uncertainty of
measurement that a laboratory ca n achieve within its scope of ac creditation when performing more
or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring
equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of
confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific
calibration performed by the laboratory may be greater than the CMC uncertainty due to the behavior
of the customer’s device and to influences from the circumstances of the specific calibration.
3 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured
value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range
or as a percent or fraction of the reading plus a fixed floor specification.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The type of instrument or material being calibrate d is defined by the parameter. This indicates the
laboratory is capable of calibratin g instruments that measure or gene rate the values in the ranges
indicated for the listed measurement parameter.
6 In the statement of CMC, percent is defined as percent of reading.
7 Digitized DC Voltage method utilized | 10 to 1000000 Hz |
| 29 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.