Associated Environmental Systems
15 Wellman Ave., 01863, North Chelmsford, MA, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 3964.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
| 2 | - | RTD Indicating Systems; Relative Humidity; TemperatureShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3964.01) Revised 02/25/2026 Page 2 of 3
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTD Indicating Systems3 –
Pt 385 100 Ω
(-200 to 250) °C
0.72 °C
Process calibrator
II. Thermodynamics
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Relative Humidity3 –
Measure
(10 to 95) % RH
3.6 % RH
Hygrometer
Temperature3 – Measure
(-80 to 0) °C
(0 to 200) °C
(0 to 760) °C
(0 to 1100) °C
(-73 to 0) °C
(12 to 45) °C
(0 to 100) °C
1.4 °C
2.5 °C
2.3 °C
1.7 °C
0.35 °C
0.29 °C
0.41 °C
Process calibrator
with J, K and T
thermocouples
Fluke 2638A hydra
data logger with
Class A RTD
___________________________________________
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy. | - |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3964.01) Revised 02/25/2026 Page 3 of 3
5 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as eith er a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 This parameter can be used to simulate sensors and the report may indicate the sensor parameter. | ||
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Hitachi High-Tech AmericaWestford, MA · ~8 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Cal-Tek CompanyNorth Billerica, MA · ~10 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hayes Instrument ServiceBillerica, MA · ~13 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - BostonBillerica, MA · ~13 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- M Precision Laboratories,Shirley, MA · ~24 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.