Associated Environmental Systems

15 Wellman Ave., 01863, North Chelmsford, MA, United States

Visit website
A2LA 3964.01ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
4
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 3964.01 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--
2-RTD Indicating Systems; Relative Humidity; Temperature
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3964.01) Revised 02/25/2026 Page 2 of 3 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTD Indicating Systems3 – Pt 385 100 Ω (-200 to 250) °C 0.72 °C Process calibrator II. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Relative Humidity3 – Measure (10 to 95) % RH 3.6 % RH Hygrometer Temperature3 – Measure (-80 to 0) °C (0 to 200) °C (0 to 760) °C (0 to 1100) °C (-73 to 0) °C (12 to 45) °C (0 to 100) °C 1.4 °C 2.5 °C 2.3 °C 1.7 °C 0.35 °C 0.29 °C 0.41 °C Process calibrator with J, K and T thermocouples Fluke 2638A hydra data logger with Class A RTD ___________________________________________ 1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
-
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3964.01) Revised 02/25/2026 Page 3 of 3 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as eith er a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This parameter can be used to simulate sensors and the report may indicate the sensor parameter.
4ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

15 Wellman Ave., North Chelmsford, MA, 01863, US

42.63898, -71.38284

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.