Cal-Tek Company

20 Republic Rd, 01862, North Billerica, MA, United States

Visit website
A2LA 7440.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
17
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 17 scope lines.

A2LA certificate 7440.01 · 17 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994-to 12 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 2 of 16 Parameter/Equipment Range CMC2, 4 (±) Comments Height Gages 3 Up to 24 in 720 μin Starrett – Weber B89 Grade 0 gage blocks, long block set, surface plate Ring Gages 3 (0.25 to 12) in (13 + 5L) μin Labmaster TM, master rings II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Generate3 Up to 220 mV 220 mV to 2.2 V (2.2 to 11) V (11 to 22) V (22 to 220) V 220 V to 1.1 kV 10 V 6.8 µV/V + 0.4 µV 3.8 µV/V + 0.7 µV 2.8 µV/V + 2.5 µV 2.9 µV/V + 4 µV 3.8 µV/V + 40 µV 4.8 µV/V + 0.4 mV 14 µV Fluke 5730A multiproduct calibrator Fluke 732A DC Voltage – Measure3 Up to 200 mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1050) V (1 to 10) kV (10 to 120) kV 9.1 µV/V + 0.2 µV 3.1 µV/V + 0.3 µV 3.0 µV/V + 0.5 µV 4.7 µV/V + 30 µV 4.8 µV/V + 0.5 mV 0.37 mV/V + 30 mV 1.1 mV/V + 0.6 V Fluke 8588A reference multimeter Vitrek 4700 Ross VD120- 6.2Y-A voltage divider, HP 34401A 6.5- digit multimeter
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 3 of 16 Parameter/Equipment Range CMC2, 5 (±) Comments DC Current – Generate 3 Up to 220 μA 220 μA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A (11 to 20.5) A 36 µA/A + 6 nA 31 µA/A + 7 nA 34 µA/A + 40 nA 46 µA/A + 0.7 µA 64 µA/A + 12 µA 0.35 mA/ A + 0.48 mA 0.79 mA/A + 0.59 mA Fluke 5730A multiproduct calibrator Fluke 5725A amplifier Fluke 5522A calibrator DC Current Clamps – Generate3 (20 to 150) A (150 to 1025) A 4.2 mA/A + 0.11 A 4.2 mA/A + 0.39 A Fluke 5522A, Fluke 5500A/COIL DC Current – Measure3 Up to 20 µA (20 to 200) µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A (20 to 30) A 35 µA/A + 0.4 nA 12 µA/A + 0.4 nA 11 µA/A + 4 nA 15 µA/A + 40 nA 59 µA/A + 1 µA 0.14 mA/A + 0.1 mA 0.24 mA/A + 0.4 mA 0.57 mA/A + 4.4 mA Fluke 8588A reference multimeter Resistance – Generate 3, Fixed Points 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 41 µΩ 81 µΩ 0.16 mΩ 0.29 mΩ 0.44 mΩ 1.1 mΩ 2.2 mΩ 7.9 mΩ 15 mΩ 68 mΩ 0.15 Ω 1.1 Ω 1.8 Ω 15 Ω 32 Ω 0.42 kΩ 0.95 kΩ 12 kΩ Fluke 5730A multiproduct calibrator
to 20.5 A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 4 of 16 Parameter/Equipment Range CMC2, 5 (±) Comments Resistance – Generate 3, Fixed Points (cont) 1 Ω 10 kΩ 8.6 µΩ 42 mΩ IET SRL resistors Resistance – Generate 3, (Simulated) Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω 330 Ω to 1.1 kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ 330 kΩ to 1.1 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ 330 MΩ to 1.1 GΩ 32 µΩ/Ω + 0.78 mΩ 26 µΩ/Ω + 1.2 mΩ 24 µΩ/Ω + 1.1 mΩ 23 µΩ/Ω + 1.6 mΩ 23 µΩ/Ω + 1.6 mΩ 23 µΩ/Ω + 16 mΩ 23 µΩ/Ω + 16 mΩ 23 µΩ/Ω + 0.16 Ω 23 µΩ/Ω + 0.16 Ω 28 µΩ/Ω + 1.6 Ω 28 µΩ/Ω + 1.6 Ω 74 µΩ/Ω + 24 Ω 0.11 mΩ/Ω + 39 Ω 0.40 mΩ/Ω + 2 kΩ 0.55 mΩ/Ω + 2.4 kΩ 4.0 mΩ/Ω + 78 kΩ 14 mΩ/Ω + 0.39 MΩ Fluke 5522A multiproduct calibrator Resistance – Measure3 Up to 2 Ω (2 to 20) Ω (20 to 200) Ω 200 Ω to 2 kΩ (2 to 20) kΩ (20 to 200) kΩ 200 kΩ to 2 MΩ (2 to 20) MΩ (20 to 200) MΩ 200 MΩ to 2 GΩ (2 to 20) GΩ 19 µΩ/Ω + 4 µΩ 12 µΩ/Ω + 14 µΩ 9.6 µΩ/Ω + 50 µΩ 9.3 µΩ/Ω + 0.5 mΩ 9.6 µΩ/Ω + 5 mΩ 10 µΩ/Ω + 50 mΩ 15 µΩ/Ω + 1 Ω 20 µΩ/Ω + 10 Ω 88 µΩ/Ω + 1 kΩ 0.26 mΩ/Ω + 0.1 MΩ 1.4 mΩ/Ω + 10 MΩ Fluke 8588A reference multimeter
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 5 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate3 Up to 2.2 mV (2.2 to 22) m V (22 to 220) mV 220 mV to 2.2 V (2.2 to 22) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1MHz 0.40 mV/V + 4 µV 0.26 mV/V + 4 µV 0.25 mV/V + 4 µV 0.52 mV/V + 4 µV 0.86 mV/V + 5 µV 1.6 mV/V + 10 µV 2.6 mV/V + 20 µV 3.1 mV/V + 20 µV 0.27 mV/V + 4 µV 0.13 mV/V + 4 µV 93 µV/V + 4 µV 0.21 mV/V + 4 µV 0.49 mV/V + 5 µV 0.93 mV/V + 10 µV 1.4 mV/V + 20 µV 3.2 mV/V + 20 µV 0.24 mV/V + 12 µV 96 µV/V + 7 µV 62 µV/V + 7 µV 0.12 mV/V + 7 µV 0.32 mV/V + 17 µV 0.61 mV/V + 20 µV 1.3 mV/V + 25 µV 2.8 mV/V + 45 µV 0.24 mV/V + 40 µV 89 µV/V + 15 µV 47 µV/V + 8 µV 68 µV/V + 10 µV 97 µV/V + 30 µV 0.33 mV/V + 80 µV 0.92 mV/V + 0.2 mV 1.9 mV/V + 0.3 mV 0.24 mV/V + 0.4 mV 92 µV/V + 0.15 mV 48 µV/V + 50 µV 70 µV/V + 0.1 mV 0.11 mV/V + 0.2 mV 0.31 mV/V + 0.6 mV 0.99 mV/V + 2 mV 1.9 mV/V + 3.2 mV Fluke 5730A multiproduct calibrator
to 2.2 V
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 6 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate3 (cont) (22 to 220) V (220 to 1100) V (220 to 1100) V (220 to 750) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (15 to 50) Hz 50 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz (30 to 50) kHz (50 to 100) kHz 0.24 mV/V + 4 mV 93 µV/V + 1.5 mV 56 µV/V + 0.6 mV 86 µV/V + 1 mV 0.16 mV/V + 2.5 mV 0.82 mV/V + 16 mV 4.3 mV/V + 40 mV 7.2 mV/V + 80 mV 0.27 mV/V + 16 mV 70 µV/V + 2.5 mV 0.13 mV/V + 6 mV 0.38 mV/V + 11 mV 0.38 mV/V + 11 mV 1.4 mV/V + 45 rnV Fluke 5730A multiproduct calibrator Fluke 5725A amplifier AC Voltage – Measure3 (1 to 12) mV (12 to 120) mV 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz 0.35 mV/V + 1.1 µV 0.42 mV/V + 1.1 µV 0.43 mV/V + 1.1 µV 3.1 mV/V + 1.1 µV 11 mV/V + 4 µV 21 mV/V + 4 µV 95 µV/V + 0.5 µV 0.14 mV/V + 0.5 µV 0.24 mV/V + 1 µV 0.54 mV/V + 5 µV 2.2 mV/V + 30 µV 12 mV/V + 0.1 mV 15 mV/V + 0.5 mV 42 mV/V + 1 mV 85 mV/V + 1 mV 0.17 V/V + 1 mV Fluke 8588A reference multimeter
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 7 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Measure3 (cont) 120 mV to 1.2 V (1.2 to 12) V (12 to 120) V (120 to 1050) V (1 to 10) kV (10 to 84) kV 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (30 to 200) Hz (45 to 65) Hz 78 µV/V + 5 µV 0.13 mV/V + 5 µV 0.23 mV/V + 10 µV 0.54 mV/V + 50 µV 2.2 mV/V + 0.3 mV 11 mV/V + 1 mV 16 mV/V + 5 mV 41 mV/V + 10 mV 83 mV/V + 10 mV 0.16 V/V + 10 mV 78 µV/V + 50 µV 0.13 mV/V + 50 µV 0.23 mV/V + 0.1 mV 0.54 mV/V + 0.5 mV 2.2 mV/V + 3 mV 11 mV/V + 10 mV 15 mV/V + 50 mV 41 mV/V + 0.1 V 83 mV/V + 0.1 V 0.16 V/V + 0.1 V 93 µV/V + 0.5 mV 0.12 mV/V + 0.5 mV 0.25 mV/V + 1 mV 0.62 mV/V + 5 mV 3.9 mV/V + 50 mV 13 mV/V + 0.5 V 0.12 mV/V + 25 mV 0.12 mV/V + 25 mV 0.24 mV/V + 25 mV 0.64 mV/V + 0.1 V 1.5 mV/V + 0.1 V 5.5 mV/V + 30 V Fluke 8588A reference multimeter Vitrek 4700 Ross VD120-6.2Y-A voltage divider, HP 34401A 6.5-digit multimeter
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 8 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Generate3 (9 to 220) µA 220 μA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 0.29 mA/A + 16 nA 0.17 mA/A + 10 nA 0.11 mA/A + 8 nA 0.26 mA/A + 12 nA 0.91 mA/A + 65 nA 0.31 mA/A + 40 nA 0.18 mA/A + 35 nA 0.12 mA/A + 35 nA 0.19 mA/A + 0.11 µA 0.91 mA/A + 0.65 µA 0.30 mA/A + 0.4 µA 0.18 mA/A + 0.35 µA 0.11 mA/A + 0.35 µA 0.19 mA/A + 0.55 µA 0.91 mA/A + 5 µA 0.31 mA/A + 4 µA 0.17 mA/A + 3.5 µA 0.11 mA/A + 2.5 µA 0.20 mA/A + 3.5 µA 0.91 mA/A + 10 µA 0.23 mA/A + 35 µA 0.40 mA/A + 80 µA 6.0 mA/A + 0.16 mA 0.41 mA/A + 0.17 mA 0.86 mA/A + 0.38 mA 3.4 mA/A + 0.75 mA 0.95 mA/A + 3.9 mA 1.2 mA/A + 3.9 mA 24 mA/A + 3.9 mA Fluke 5730A multiproduct calibrator Fluke 5725A amplifier Fluke 5522A multiproduct calibrator
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 9 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current Clamps– Generate 3 (20 to 150) A (150 to 1000) A (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 4.6 mA/A + 0.2 A 8.2 mA/A + 0.2 A 4.7 mA/A + 0.7 A 11 mA/A + 0.73 A Fluke 5522A, 5500A/COIL AC Current – Measure3 (1 to 20) µA (20 to 200) µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A (20 to 30) A 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz 10 Hz to 2 kHz (2 to 10) kHz 2.2 mA/A + 2.5 nA 2.2 mA/A + 2.5 nA 2.3 mA/A + 2.5 nA 0.31 mA/A + 5 nA 0.55 mA/A + 5 nA 0.84 mA/A + 5 nA 4.2 mA/A + 10 nA 0.29 mA/A + 50 nA 0.54 mA/A + 50 nA 0.82 mA/A + 50 nA 4.1 mA/A + 0.1 µA 0.29 mA/A + 0.5 µA 0.54 mA/A + 0.5 µA 0.83 mA/A + 0.5 µA 4.1 mA/A + 1 µA 0.29 mA/A + 5 µA 0.53 mA/A + 5 µA 0.83 mA/A + 5 µA 0.31 mA/A + 0.1 mA 0.56 mA/A + 0.1 mA 0.83 mA/A + 0.1 mA 0.85 mA/A + 0.5 mA 0.85 mA/A + 0.5 mA 0.87 mA/A + 12 mA 1.6 mA/A + 12 mA Fluke 8588A reference multimeter
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 10 of 16 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouple Indicating Devices – Generate/Measure 3 – Type B Type C Type E Type J Type K (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (0 to 150) °C (150 to 650) °C (650 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to-30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (l000 to 1372) °C 0.35 °C 0.28 °C 0.24 °C 0.27 °C 0.24 °C 0.21 °C 0.25 °C 0.4 °C 0.66 °C 0.41 °C 0.14 °C 0.13 °C 0.14 °C 0.18 °C 0.28 °C 0.16 °C 0.14 °C 0.16 °C 0.2 °C 0.28 °C 0.16 °C 0.15 °C 0.22 °C 0.33 °C Fluke 5522A multiproduct calibrator
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 11 of 16 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouple Indicating Devices – Generate/Measure 3 – (cont) Type L Type N Type R Type S Type T Type U (-200 to -100) °C (-100 to 800) °C (800 to 900) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C (-200 to 0) °C (0 to 600) °C 0.31 °C 0.22 °C 0.16 °C 0.33 °C 0.19 °C 0.17 °C 0.16 °C 0.22 °C 0.46 °C 0.29 °C 0.27 °C 0.32 °C 0.38 °C 0.29 °C 0.3 °C 0.37 °C 0.54 °C 0.24 °C 0.17 °C 0.14 °C 0.44 °C 0.22 °C Fluke 5522A multiproduct calibrator Electrical Simulation of RTD Indicating Devices 3 – Pt 385, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.097 °C 0.11 °C 0.12 °C 0.13 °C 0.14 °C 0.16 °C 0.22 °C Fluke 5522A multiproduct calibrator
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 12 of 16 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Electrical Simulation of RTD Indicating Devices 3 – (cont) Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.097 °C 0.1 °C 0.11 °C 0.12 °C 0.14 °C 0.15 °C 0.21 °C 0.092 °C 0.096 °C 0.11 °C 0.11 °C 0.12 °C 0.12 °C 0.14 °C 0.21 °C 0.054 °C 0.057 °C 0.056 °C 0.064 °C 0.11 °C 0.12 °C 0.13 °C 0.14 °C 0.037 °C 0.044 °C 0.044 °C 0.051 °C 0.066 °C 0.067 °C 0.074 °C 0.089 °C Fluke 5522A multiproduct calibrator
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 13 of 16 Parameter/Equipment Range CMC2, 5 (±) Comments Electrical Simulation of RTD Indicating Devices 3 – (cont) Pt 385, 1000 Ω PtNi 385, 120 Ω (Ni 120) Cu 427, 10 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (-100 to 260) °C 0.025 °C 0.025 °C 0.033 °C 0.041 °C 0.048 °C 0.056 °C 0.056 °C 0.18 °C 0.088 °C 0.078 °C 0.12 °C 0.94 °C Fluke 5522A multiproduct calibrator Oscilloscopes3 – AC Voltage 50 Ω Load 1 MΩ Load DC Voltage 50 Ω Load 1 MΩ Load Leveled Sine Wave 50 Ω Load Time Markers Sinewave Sine/Square-wave Spike/Square-wave Spike. Square-wave, Pulse Spike, Square-wave 1 mVp-p to 6.6 Vp-p 1 mVp-p to 130 Vp-p (-6.6 to 6.6) V (-130 to .130) V 5 m Vp-p to 2.5 Vp-p 50 kHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 5 mVp-p to 3.5 Vp-p 600 MHz to 1.1 GHz (2 to 5) ns 10 ns (20 to 50) ns 100 ns to 20 ms 50 ms to 5 s 2.4 mV/V + 32 µV 0.78 mV/V + 32 µV 2.5 mV/V + 32 µV 0.39 mV/V + 32 µV 17 mV/V + 0.24 mV 14 mV/V + 78 µV 19 mV/V + 78 µV 33 mV/V + 78 µV 41 mV/V + 78 µV 2.0 µs/s 2.0 µs/s 2.0 µs/s 2.0 µs/s (25 + 1000T) μs/s Fluke 5522A/11 multiproduct calibrator with 1.1 GHz scope option T is time in seconds
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 14 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments Capacitance – Generate 3 (Simulated) (220 to 400) pF 400 pF to 1.1 μF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF 330 nF to 1.1 μF (1.1 to 3.3) μF (3.3 to 11) μF (11 to 33) μF (33 to 110) μF (110 to 330) μF 330 μF to 1.1 mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 5.4 mF/F + 7.8 pF 4.2 mF/F + 7.8 pF 4.4 mF/F + 7.8 pF 2.7 mF/F + 7.8 pF 2.4 mF/F + 78 pF 2.7 mF/F + 78 pF 2.6 mF/F + 0.24 nF 2.7 mF/F + 0.78 nF 2.6 mF/F + 2.4 nF 2.7 mF/F + 7.8 nF 3.6 mF/F + 24 nF 4.0 mF/F + 78 nF 3.5 mF/F + 0.24 µF 3.5 mF/F + 0.78 µF 3.5 mF/F + 2.4 µF 3.5 mF/F + 7.8 µF 5.8 mF/F + 24 µF 8.6 mF/F + 78 µF Fluke 5522A multiproduct calibrator III. Mechanical Parameter/Equipment Range CMC2, 6 (±) Comments Torque Indicating Devices 3 (4 to 40) ozf∙in (2 to 20) lbf∙in (20 to 200) lbf∙in (10 to 100) lbf∙ft (100 to 1000) lbf∙ft 2.2 % of reading + 0.005 ozf∙in 0.19 % of reading + 0.002 lbf∙in 0.19 % of reading + 0.02 lbf∙in 0.29 % of reading + 0.01 lbf∙ft 1.3 % of reading + 0.1 lbf∙ft AKO TSD 6500 torque calibrator Vacuum – Measuring Equipment 3 (-14 to 0) psi 0.0042 psi Additel 912A pump, Additel 681 gauge
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 15 of 16 Parameter/Equipment Range CMC2, 6 (±) Comments Pressure – Measuring Equipment 3 Pneumatic Hydraulic (0 to 30) psig (30 to 100) psig (100 to 300) psig (300 to 1000) psig (1000 to 15 000) psig 0.0036 psi 0.018 % of reading 0.057 psi 0.018 % of reading 0.041 % of reading Fluke PPC4 pressure calibrator Ametek TQ-150 deadweight tester IV. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Measure/ Measuring Equipment 3 (-25 to 0) °C (0 to 50) °C (50 to 150) °C (150 to 200) °C (200 to 350) °C (350 to 420) °C (420 to 660) °C 0.064 °C 0.065 °C 0.067 °C 0.23 °C 0.37 °C 0.43 °C 0.63 °C Fluke 5615-9-A PRT, Fluke 9142-P field metrology well Fluke 5609-12-A PRT, Fluke 9144-P field metrology well V. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measuring Equipment 3 1 μHz to 80 MHz 80 MHz to 3.0 GHz 38 pHz/Hz 30 pHz/Hz SRS FS740 GPS: Agilent 33250A function/arbitrary waveform generator Agilent N931 0A Signal Generator
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7440.01) Revised 08/19/2025 Page 16 of 16 Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measure3 100 mHz to 225 MHz 225 MHz to 3.0 GHz 50 pHz/Hz 30 pHz/Hz SRS FS740 GPS, HP 53131A universal counter Stopwatches, Timers3 Up to 20 s/d 65 ms/d Helmut Klein 4500 Timometer ___________________ 1 This laboratory offers commercial calibration and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the nominal numerical value of the length of the unit under test in inches. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification 6 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
17ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

20 Republic Rd, North Billerica, MA, 01862, US

42.58526, -71.28776

Open in Maps