FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Poland

Pracownia Pomiarów Czynników Szkodliwych na Stanowiskach Pracy - Adam Batko

ul. Tarnowska 59, 33-300, Nowy Sącz, Poland

PCA|AB 1206ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
4
Standards
6
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Pracownia Pomiarów Czynników Szkodliwych na Stanowiskach Pracy - Adam Batko?

Claim this profile to keep it accurate.

Register record

PCARefreshed
AB 1206Active

Accredited standards

6

Our reading of the PCA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidanceCertificate says EN 14253+A1:2011. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 3 (PCA AB 1206)

PN-EN 14253+A1:2011; PN-Z-04008-7:2022+Az1:2004

ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
As written on the certificate · Line 2 (PCA AB 1206)

PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11

ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
As written on the certificate · Line 2 (PCA AB 1206)

PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11

ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
As written on the certificate · Line 2 (PCA AB 1206)

PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11

PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
As written on the certificate · Line 2 (PCA AB 1206)

PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11

PN-Z-04507:2022-05Ochrona czystości powietrza - Oznaczanie frakcji wdychalnej aerozolu na stanowiskach pracy metodą grawimetryczną
As written on the certificate · Line 4 (PCA AB 1206)

PN-Z-04507:2022-05; PN-Z-04507:2022-05+A1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05+A1:2022-08

Scope as published by PCA

4 lines
PCA

ISO/IEC 17025

Active

AB 1206

The scope document we hold says it was valid until 2026-07-11. That date has passed, so our copy may be out of date. We downloaded it from the PCA register on 2026-03-13. Check the PCA register for the current scope.

View on PCA

Accredited scope, certificate AB 1206

LineDisciplineMethodMatrixRange
1environmental-working environment (harmful and nuisance factors noise, vibration); working environment (harmful factors – air)-
2environmentalPN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11Workplace environment20 to 135 dB
3environmentalPN-EN 14253+A1:2011; PN-Z-04008-7:2022+Az1:2004Workplace environment0.04 to 10 m/s2
4environmentalPN-Z-04507:2022-05; PN-Z-04507:2022-05+A1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05+A1:2022-08Ambient air0.14 to 17.7 mg/m3

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Tarnowska 59, Nowy Sącz, 33-300, PL

49.62492, 20.69135

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.