CDC Clinical Reference Laboratory (CDC CRL)
4770 Buford Hwy. NE., MS S110-2, 30341, Atlanta, GA, United States
- Accredited standards
- 1
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ISO 15195Laboratory medicine - Requirements for the competence of calibration laboratories using reference measurement procedures
ISO/IEC 17025:2017; ISO 15195:2018; IEC 17025
ISO/IEC 17025:2017; ISO 15195:2018 and R205; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025
Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-06.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active6909.01
The scope document we hold says it was valid until 2026-03-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.
Accredited scope, certificate 6909.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ISO 15195:2018; IEC 17025 | Serum | 25 to 400 mg/dL |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6909.01) 02/26/2025 Page 2 of 2
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, percentages represent the percent of reading unless otherwise noted.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 3 | ISO/IEC 17025:2017; ISO 15195:2018 and R205; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.