TUV SUD Japan Ltd. Yonezawa Testing Center (EMC Lab)
Yonezawa Testing Center, 5-4149-7 Hachimanpara, Yonezawa-shi, Yamagata, 992-1128, Japan, Yamagata, Japan
Visit website- Accredited standards
- 89
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 89 standard numbers and the 40 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series22
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national
National versions in the same scope
KS C 9610-4-2national version with changes
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national
National versions in the same scope
KS C 9610-4-3national version with changes
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national
National versions in the same scope
KS C 9610-4-4national version with changes
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+1 national
National versions in the same scope
KS C 9610-4-5national version with changes
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+1 national
National versions in the same scope
KS C 9610-4-6national version with changes
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test+1 national
National versions in the same scope
KS C 9610-4-8national version with changes
IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+1 national
National versions in the same scope
KS C 9610-4-11probably the same standard; matched by number only
IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
IEC 61000-4-16
Show all 22
IEC 61000-4-20
IEC 61000-4-28
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+2 national
National versions in the same scope
AS/NZS 61000.6.2national version with changes
KS C 9610-6-2national version with changes
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
AS/NZS 61000.6.3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national
National versions in the same scope
KS C 9610-6-4national version with changes
IEC 61000-6-7
IEC 61000-6-8
ETSI16
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrumSome clauses
Limits written next to it
ETSI EN 300 328 (only clauses 4.3.1.10, 4.3.1.11, 4.3.2.9, 4.3.2.10)
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 440
ETSI EN 301 489-1Exclusion
Limits written next to it
EMC - Radio equipment EN 301 489-1 (excluding clause 9.6)
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 489-52
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EUSome clauses
Limits written next to it
ETSI EN 301 511 (only clauses 4.2.16, 4.2.17, 4.2.18, 4.2.19)
ETSI EN 301 843-1
ETSI EN 301 843-2
ETSI EN 301 843-5
ETSI EN 301 893Some clauses
Limits written next to it
ETSI EN 301 893 (only clauses 4.2.4.1, 4.2.5)
ETSI EN 301 908-1Some clauses
Limits written next to it
ETSI EN 301 908-1 (only clauses 4.2.2, 4.2.3, 4.2.4)
ETSI EN 301 908-2Some clauses
Limits written next to it
ETSI EN 301 908-2 (only clauses 4.2.4, 4.2.10)
ETSI EN 301 908-13Some clauses
Limits written next to it
ETSI EN 301 908-13 (only clauses 4.2.4, 4.2.10)
ETSI EN 303 687Some clauses
Limits written next to it
ETSI EN 303 687 (only clauses 4.3.4.1, 4.3.4.2, 4.3.5)
IEC14
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirementsSome clauses
Limits written next to it
EN 60335-1 (only clause 19.11.4)
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test resultsSome clauses
Limits written next to it
EN 60945(only section 9 and 10)
IEC 60947-5-2Some clauses
Limits written next to it
EN IEC 60947-5-2 (only clause 8.2.6 and 9.6)
IEC 60947-5-3Some clauses
Limits written next to it
EN 60947-5-3 (only clause 7.3.3)
IEC 61131-2Some clauses
Limits written next to it
EMC - Programable controller IEC 61131-2 (only clause 7)
EN 61131-2 (only clause 8)
IEC 61131-6Some clauses
Limits written next to it
EN 61131-6 (only clause 12.5)
IEC 61496-1Some clauses
Limits written next to it
EN IEC 61496-1 (only clause 4.3.2 and 5.4.3)
IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools
IEC 61800-5-2Some clauses
Limits written next to it
EN 61800-5-2 (only clause 9.3 and Annex E)
IEC 62061
IEC 62233Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 80601-2-30Medical electrical equipment - Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometersSome clauses
Limits written next to it
IEC 80601-2-30 (clause 202 only)
IEC 60601 series10
IEC 60601-2-18Some clauses
Limits written next to it
EN 60601-2-18 (clause 202 only)
IEC 60601-2-21
IEC 60601-2-22
IEC 60601-2-24
IEC 60601-2-25Some clauses
Limits written next to it
ANSI AAMI IEC 60601-2-25 (clause 202 only)
IEC 60601-2-27Some clauses
Limits written next to it
ANSI AAMI IEC 60601-2-27 (clause 202 only)
IEC 60601-2-30
IEC 60601-2-37Some clauses
Limits written next to it
IEC 60601-2-37:2007 + AMD1:2015 (clause 202 only)
IEC 60601-2-39
IEC 60601-2-47Some clauses
Limits written next to it
ANSI AAMI IEC 60601-2-47 (clause 202 only)
EN9
EN 12015Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission
EN 12016
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50364Exclusion
Limits written next to it
EN 50364:2010 (Excluding contact current and limb
EN 50370-1
EN 50370-2
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50664
EN 50665
ISO4
ISO 13849-1Safety of machinery - Safety-related parts of control systems - Part 1: General principles for designSome clauses
Limits written next to it
EN ISO 13849-1 (only clause F.3.6.9)
EN ISO 13849-1:2015 (only Table F.1 No.6)
ISO 16090-1Machine tools safety - Machining centres, milling machines, transfer machines - Part 1: Safety requirementsSome clauses
Limits written next to it
EN ISO 16090-1 (only clause 5.8.8)
ISO 23125Machine tools - Safety - Turning machinesSome clauses
Limits written next to it
EN ISO 23125 (only clause 5.8 paragraph k)
ISO 80601-2-74Medical electrical equipment - Part 2-74: Particular requirements for basic safety and essential performance of respiratory humidifying equipmentSome clauses
Limits written next to it
ISO 80601-2-74 (clause 202 only)
EN 50121 series3
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50121-5
IEC 61326 series3
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
IEC 61326-3-1
IEC 61326-3-2
IEC 62236 series3
IEC 62236-3-2
IEC 62236-4
IEC 62236-5
Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI/TIA-603-E
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS CISPR 11national version with changes
KS C 9811national version with changes
FCC PART 15Radio Frequency Devices
ICES-003
IEC 61000-4-3:2020; IEC 61000-4-3:2006+A1:2007+A2:2010; EN IEC 61000-4-3:2020; EN 61000-4-3:2006+A1:2008+A2:2010; KS C 9610-4-3; JIS C 61000-4-3; EN 61000-4-4; IEC 61000-4-4; KS C 9610-4-4; JIS C 61000-4-4; EN 61000-4-5; IEC 61000-4-5; KS C 9610-4-5; JIS C 61000-4-5; EN 61000-4-6; IEC 61000-4-6; KS C 9610-4-6; JIS C 61000-4-6; EN IEC 61000-4-6; IEC 61000-4-6:2013; EN 61000-4-6:2014; EN 61000-4-8; IEC 61000-4-8; KS C 9610-4-8; JIS C 61000-4-8; EN 61000-4-9; IEC 61000-4-9; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; KS C 9610-4-11; JIS C 61000-4-11; EN 61000-4-13; IEC 61000-4-13; IEC 61000-4-16; EN 61000-4-16; IEC 61000-4-28; EN 61000-4-28; IEC 61000-4-29; EN 61000-4-29; EN 61000-4-39; IEC 61000-4-39; IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; JIS C 61000-3-2; GB 17625.1; IEC 61000-3-2:2005+A1:2008+A2:2009; EN IEC 61000-3-2:2019; IEC 61000-3-12; EN 61000-3-12:2011
47 CFR FCC Parts 22, 24, 25, 27, (using ANSI 63.26:2015; ANSI/TIA-603-E); ETSI EN 300 330; ETSI EN 300 440; ETSI EN 301 511; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI EN 301 908-13; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 303 687; RSS-GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-199; RSS-210; RSS-247; RSS-248; EN 50364; EN 50364:2010; EN 50663; EN 50664; EN 50665; EN 62233; IEC 62233; EN 62311; EN IEC 62311; IEC 62311; EN 62479; IEC 62479; ICES-001; CISPR 11; EN 55011; J55011 H27; AS CISPR 11; KS C 9811; CISPR 11:2015+A1:2016+A2:2019; EN 55011:2016+A11:2020; IEC 61000-6-1; EN IEC 61000-6-1; JIS C 61000-6-1; EN 61000-6-1; IEC 61000-6-2; EN IEC 61000-6-2; JIS C 61000-6-2; EN 61000-6-2; AS/NZS 61000.6.2; KS C 9610-6-2; IEC 61000-4-2; EN 61000-4-2:2009; JIS C 61000-4-2; KS C 9610-4-2
47 CFR FCC Part 15, Subpart B (using ANSI C63.4:2014); 47 CFR FCC Part 18 (using FCC MP-5); ICES-003; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; AS/NZS 61000.6.3; IEC 61000-6-4; EN IEC 61000-6-4; EN 61000-6-4; AS 61000.6.4; KS C 9610-6-4; IEC 61000-6-8 (except IEC 61000-4-20); 47 CFR FCC Part 15, Subpart C (using ANSI C63.10:2013 and ANSI C63.10:2020); 47 CFR FCC Part 15, Subpart E (using ANSI C63.10:2013 and ANSI C63.10:2020); ANSI C63.10-2020 + Cor.1-2023; ANSI C63.10-2020 + Cor. 1-2023 + C63.10a-2024; FCC KDB 905462 D02 (v02); 47 CFR FCC Part 18 (using FCC MP-5)
ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI C63.10:2020; FCC KDB 905462 D02 (v02); EN 50370-1; EN 50370-2; EN 301 489-1; EN 301 489-3; EN 301 489-17; EN 301 489-52; EN 301 843-1; EN 301 843-2; EN 301 843-5; IEC 60335-1; IEC 60335-1:2010+A1:2013+A2:2016; EN 60335-1; IEC 61326-3-1; EN 61326-3-1; JIS C 61326-3-1; IEC 61326-3-2; EN IEC 61326-3-2; IEC 61496-1; EN IEC 61496-1; IEC 61800-5-2; EN 61800-5-2; IEC 61000-6-7; EN 61000-6-7; IEC 60947-5-2; EN IEC 60947-5-2; IEC 60947-5-3; EN 60947-5-3; IEC 62061; EN 62061; EN IEC 62061; ISO 13849-1; EN ISO 13849-1; ISO 13849-1:2015; EN ISO 13849-1:2015; ISO 16090-1; EN ISO 16090-1; ISO 23125; EN ISO 23125
EN 60601-2-18; IEC 60601-2-21; EN IEC 60601-2-21; JIS T 0601-2-21; IEC 60601-2-22; EN IEC 60601-2-22; JIS T 0601-2-22; IEC 60601-2-24; EN 60601-2-24; JIS T 0601-2-24; IEC 60601-2-25; EN 60601-2-25; JIS T 0601-2-25; ANSI AAMI IEC 60601-2-25; IEC 60601-2-27; EN 60601-2-27; ANSI AAMI IEC 60601-2-27; IEC 60601-2-30; EN 60601-2-30; IEC 80601-2-30; IEC 60601-2-37; EN 60601-2-37; JIS T 0601-2-37; IEC 60601-2-37:2007 + AMD1:2015; IEC 60601-2-39; EN IEC 60601-2-39; JIS T 0601-2-39; IEC 60601-2-47; IEC 60601-2-47:2012; EN 60601-2-47; ANSI AAMI IEC 60601-2-47; ISO 80601-2-74; IEC TS 60601-4-2; IEC TR 60601-4-2; IEC 61326-2-6; EN IEC 61326-2-6; JIS C 61326-2-6; EN 50121-3-2; IEC 62236-3-2; EN 50121-4; IEC 62236-4; EN 50121-5; IEC 62236-5; IEC 60945; EN 60945; IEC 61800-3; EN IEC 61800-3; EN 61800-3; IEC 61800-3:2017; IEC 61131-2; EN 61131-2; IEC 61131-6; EN 61131-6; EN 12015:2014; EN 12015; EN 12016; EN 50130-4
ANSI/TIA-603-E; ANSI C63.26:2015
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
8 lines
ISO/IEC 17025
Active3686.03
The scope document we hold says it is valid until 2027-02-28.
Accredited scope, certificate 3686.03
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | 47 CFR FCC Part 15, Subpart B (using ANSI C63.4:2014); 47 CFR FCC Part 18 (using FCC MP-5); ICES-003; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; AS/NZS 61000.6.3; IEC 61000-6-4; EN IEC 61000-6-4; EN 61000-6-4; AS 61000.6.4; KS C 9610-6-4; IEC 61000-6-8 (except IEC 61000-4-20); 47 CFR FCC Part 15, Subpart C (using ANSI C63.10:2013 and ANSI C63.10:2020); 47 CFR FCC Part 15, Subpart E (using ANSI C63.10:2013 and ANSI C63.10:2020); ANSI C63.10-2020 + Cor.1-2023; ANSI C63.10-2020 + Cor. 1-2023 + C63.10a-2024; FCC KDB 905462 D02 (v02); 47 CFR FCC Part 18 (using FCC MP-5) | - | - |
| 2 | 47 CFR FCC Parts 22, 24, 25, 27, (using ANSI 63.26:2015; ANSI/TIA-603-E); ETSI EN 300 330; ETSI EN 300 440; ETSI EN 301 511; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI EN 301 908-13; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 303 687; RSS-GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-199; RSS-210; RSS-247; RSS-248; EN 50364; EN 50364:2010; EN 50663; EN 50664; EN 50665; EN 62233; IEC 62233; EN 62311; EN IEC 62311; IEC 62311; EN 62479; IEC 62479; ICES-001; CISPR 11; EN 55011; J55011 H27; AS CISPR 11; KS C 9811; CISPR 11:2015+A1:2016+A2:2019; EN 55011:2016+A11:2020; IEC 61000-6-1; EN IEC 61000-6-1; JIS C 61000-6-1; EN 61000-6-1; IEC 61000-6-2; EN IEC 61000-6-2; JIS C 61000-6-2; EN 61000-6-2; AS/NZS 61000.6.2; KS C 9610-6-2; IEC 61000-4-2; EN 61000-4-2:2009; JIS C 61000-4-2; KS C 9610-4-2 | - | - |
| 3 | IEC 61000-4-3:2020; IEC 61000-4-3:2006+A1:2007+A2:2010; EN IEC 61000-4-3:2020; EN 61000-4-3:2006+A1:2008+A2:2010; KS C 9610-4-3; JIS C 61000-4-3; EN 61000-4-4; IEC 61000-4-4; KS C 9610-4-4; JIS C 61000-4-4; EN 61000-4-5; IEC 61000-4-5; KS C 9610-4-5; JIS C 61000-4-5; EN 61000-4-6; IEC 61000-4-6; KS C 9610-4-6; JIS C 61000-4-6; EN IEC 61000-4-6; IEC 61000-4-6:2013; EN 61000-4-6:2014; EN 61000-4-8; IEC 61000-4-8; KS C 9610-4-8; JIS C 61000-4-8; EN 61000-4-9; IEC 61000-4-9; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; KS C 9610-4-11; JIS C 61000-4-11; EN 61000-4-13; IEC 61000-4-13; IEC 61000-4-16; EN 61000-4-16; IEC 61000-4-28; EN 61000-4-28; IEC 61000-4-29; EN 61000-4-29; EN 61000-4-39; IEC 61000-4-39; IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; JIS C 61000-3-2; GB 17625.1; IEC 61000-3-2:2005+A1:2008+A2:2009; EN IEC 61000-3-2:2019; IEC 61000-3-12; EN 61000-3-12:2011 | - | 80 to 6 MHz to GHz |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3686.03) REVISED 9/9/2025 Page 4 of 7
Test:
Test Method(s)1:
Voltage Fluctuations & Flicker IEC 61000-3-3; EN 61000-3-3;
IEC 61000-3-3:2013+A1:2017;
IEC 61000-3-3:2013; EN 61000-3-3:2013;
IEC 61000-3-11; EN 61000-3-11; EN IEC 61000-3-11
Generic Product and Industry
Specific Standards
EMC- household appliances,
electric tools and similar
apparatus
CISPR 14-1; EN 55014-1; EN IEC 55014-1; J55014-1(H27);
AS/NZS CISPR 14.1;
CISPR 14-2; EN IEC 55014-2; EN 55014-2;
EN 55014-2:1997+A1:2001+A2:2008
EMC-ITE/MME CISPR 22; EN 55022;
CISPR 32; EN 55032; VCCI-CISPR 32; CISPRJ 32; J55032;
CISPR 32:2015; EN 55032:2015+A11:2020;
AS/NZS CISPR 32; GB/T 9254.1;
CISPR 35; EN 55035 (excluding Annex A and Annex E broadband
impulse noise interference)
EMC- Electrical equipment for
measurement, control and
laboratory use
IEC 61326-1; EN 61326-1; EN IEC 61326-1 ; JIS C 61326-1;
IEC 61326-2-1; EN 61326-2-1; EN IEC 61326-2-1;
JIS C 61326-2-1;
IEC 61326-2-2; EN 61326-2-2; EN IEC 61326-2-2;
JIS C 61326-2-2;
IEC 61326-2-3; EN 61326-2-3; EN IEC 61326-2-3;
JIS C 61326-2-3;
IEC 61326-2-4; EN 61326-2-4; EN IEC 61326-2-4;
IEC 61326-2-5; EN 61326-2-5; EN IEC 61326-2-5
EMC – Medical Equipment
IEC 60601-1-2; EN 60601-1-2; JIS T 0601-1-2;
ANSI AAMI IEC 60601-1-2 (excluding ISO 7637-2 test);
IEC 60601-2-2; EN 60601-2-2; EN IEC 60601-2-2;
JIS T 0601-2-2 (clause 202 only);
IEC 60601-2-3; EN 60601-2-3 (clause 202 only);
JIS T 0601-2-3(clause 202 only);
IEC 60601-2-4; EN 60601-2-4; (clause 202 only)
ANSI AAMI IEC60601-2-4 (clause 202 only);
IEC 60601-2-5; EN 60601-2-5; JIS T 0601-2-5 (clause 202 only);
IEC 60601-2-6; EN 60601-2-6; JIS T 0601-2-6 (clause 202 only);
IEC 60601-2-10; EN 60601-2-10;
JIS T 0601-2-10 (clause 202 only);
IEC 60601-2-10:2012+A1:2016 (clause 202 only)
IEC 60601-2-16; EN IEC 60601-2-16; JIS T 0601-2-16;
ANSI AAMI IEC 60601-2-16 (clause 202 only);
IEC 60601-2-18; JIS T 0601-2-18 (clause 202 only); | ||
| 5 | EN 60601-2-18; IEC 60601-2-21; EN IEC 60601-2-21; JIS T 0601-2-21; IEC 60601-2-22; EN IEC 60601-2-22; JIS T 0601-2-22; IEC 60601-2-24; EN 60601-2-24; JIS T 0601-2-24; IEC 60601-2-25; EN 60601-2-25; JIS T 0601-2-25; ANSI AAMI IEC 60601-2-25; IEC 60601-2-27; EN 60601-2-27; ANSI AAMI IEC 60601-2-27; IEC 60601-2-30; EN 60601-2-30; IEC 80601-2-30; IEC 60601-2-37; EN 60601-2-37; JIS T 0601-2-37; IEC 60601-2-37:2007 + AMD1:2015; IEC 60601-2-39; EN IEC 60601-2-39; JIS T 0601-2-39; IEC 60601-2-47; IEC 60601-2-47:2012; EN 60601-2-47; ANSI AAMI IEC 60601-2-47; ISO 80601-2-74; IEC TS 60601-4-2; IEC TR 60601-4-2; IEC 61326-2-6; EN IEC 61326-2-6; JIS C 61326-2-6; EN 50121-3-2; IEC 62236-3-2; EN 50121-4; IEC 62236-4; EN 50121-5; IEC 62236-5; IEC 60945; EN 60945; IEC 61800-3; EN IEC 61800-3; EN 61800-3; IEC 61800-3:2017; IEC 61131-2; EN 61131-2; IEC 61131-6; EN 61131-6; EN 12015:2014; EN 12015; EN 12016; EN 50130-4 | - | - |
| 6 | ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI C63.10:2020; FCC KDB 905462 D02 (v02); EN 50370-1; EN 50370-2; EN 301 489-1; EN 301 489-3; EN 301 489-17; EN 301 489-52; EN 301 843-1; EN 301 843-2; EN 301 843-5; IEC 60335-1; IEC 60335-1:2010+A1:2013+A2:2016; EN 60335-1; IEC 61326-3-1; EN 61326-3-1; JIS C 61326-3-1; IEC 61326-3-2; EN IEC 61326-3-2; IEC 61496-1; EN IEC 61496-1; IEC 61800-5-2; EN 61800-5-2; IEC 61000-6-7; EN 61000-6-7; IEC 60947-5-2; EN IEC 60947-5-2; IEC 60947-5-3; EN 60947-5-3; IEC 62061; EN 62061; EN IEC 62061; ISO 13849-1; EN ISO 13849-1; ISO 13849-1:2015; EN ISO 13849-1:2015; ISO 16090-1; EN ISO 16090-1; ISO 23125; EN ISO 23125 | - | to 40000 MHz |
| 7 | ANSI/TIA-603-E; ANSI C63.26:2015 | - | to 40000 MHz |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA HAS ACCREDITED
TUV SUD JAPAN LTD. YONEZAWA TESTING CENTER (EMC LAB)
Yamagata, Japan
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This laboratory also meets A2LA R256
- Specific Requirements. This accreditation demonstrates technical competence for a defined scope and the
operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 18th day of August 2025.
___ ____________________
Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 3686.03
Valid to February 28, 2027
Revised September 9, 2025 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Yonezawa Testing Center, 5-4149-7 Hachimanpara, Yonezawa-shi, Yamagata, 992-1128, Japan, Yamagata, JP
38.47467, 140.08324
Open in MapsLabs with overlapping accredited scope in Japan
- UL Japan, Inc., Shonan EMCKanagawa · ~344 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- UL JapanIse-shi, Mie · ~534 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- LAB SupportAzumino-shi, Nagano-ken · ~309 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- UL Japan, Inc. - Kashima EMCChiba-ken, 289-0341 · ~314 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- Samoto & Associates,Yokohama, Kanagawa · ~339 kmA2LAShares 1 accredited test methodEN 61000-4-4
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.