Registers refreshed 2026-11-20.See refresh dates
Taiwan

SGS Taiwan

No.2, Keji 1st Rd., Guishan District, Taoyuan City, Taiwan 333, Taoyuan, Republic of China Taiwan, Taoyuan, Taiwan

Visit website

No active accreditation in the register.

Register refreshed 2026-11-20
Part of the SGS group: 171 sites in our directory.

We check which accredited labs can do it and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.

Scope as published by A2LA

7 lines
A2LA

ISO/IEC 17025

Withdrawn

7501.01

View scope

Accredited scope, certificate 7501.01

LineMethodMatrixRange
147 CFR FCC Part 15B (using ANSI C63.4); ANSI C63.43; CISPR 32; EN 55032; BS EN 55032; VCCI-CISPR 32; AS/NZS CISPR 32; IEC 61000-3-2; EN 61000-3-2; BS EN 61000-3-2; EN IEC 61000-3-2; BS EN IEC 61000-3-2; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3--
2IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; IEC 61000-4-3; EN 61000-4-3; BS EN 61000-4-3; EN IEC 61000-4-3; BS EN IEC 61000-4-3; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5; IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6; EN IEC 61000-4-6; BS EN IEC 61000-4-6; IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8; IEC 61000-4-11; EN 61000-4-11; BS EN 61000-4-11; EN IEC 61000-4-11; BS EN IEC 61000-4-11; EN 61000-4-39; IEC 61000-4-39; CISPR 35; EN 55035; BS EN 55035-80 to 6 MHz~GHz
3IEC 60601-1-2; EN 60601-1-2; BS EN 60601-1-2; ANSI/AAMI/IEC 60601-1-2; CAN CSA-C22.2 NO. 60601-1-2; AS IEC 60601.1.2; JIS T 0601-1-2; IEC TR 60601-4-2; IEC TS 60601-4-2; CSA C22.2 NO. 60601-1-2; IEC 61000-3-2; EN 61000-3-2; BS EN 61000-3-2; EN IEC 61000-3-2; BS EN IEC 61000-3-2; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; IEC 61000-4-3; EN 61000-4-3; BS EN 61000-4-3; EN IEC 61000-4-3; BS EN IEC 61000-4-3; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5Medical equipment, electrical safety and EMC80 to 6000 MHz
4IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6; EN IEC 61000-4-6; BS EN IEC 61000-4-6; IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8; IEC 61000-4-11; EN 61000-4-11; BS EN 61000-4-11; EN IEC 61000-4-11; BS EN IEC 61000-4-11; EN 61000-4-39; IEC 61000-4-39; CISPR 35; EN 55035; BS EN 55035; IEC 60601-1-2; EN 60601-1-2; BS EN 60601-1-2; ANSI/AAMI/IEC 60601-1-2; CAN CSA-C22.2 NO. 60601-1-2; AS IEC 60601.1.2; JIS T 0601-1-2; IEC TR 60601-4-2; IEC TS 60601-4-2; CSA C22.2 NO. 60601-1-2--
5CFR 47, FCC Part 15B; ANSI C63.4; ANSI C63.43; CISPR 32; EN 55032; BS EN 55032; VCCI-CISPR 32; AS/NZS CISPR 32; IEC 60601-1-2; EN 60601-1-2; BS EN 60601-1-2; ANSI/AAMI/IEC 60601-1-2; CAN CSA-C22.2 NO. 60601-1-2; AS IEC 60601.1.2; JIS T 0601-1-2; IEC TR 60601-4-2; IEC TS 60601-4-2; CSA C22.2 NO. 60601-1-2--
6ANSI C63.4:2014-to 40000 MHz
7

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited SGS TAIWAN LTD. Taoyuan, Republic of China Taiwan for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets A2LA R256 - Specific Requirements - FDA ASCA Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 12th day of June 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7501.01 Valid to June 30, 2027 Revised March 10, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.