BTL Inc.
No. 68-1, Ln. 169, Sec. 2, Datong Rd., Xizhi Dist., New Taipei City, 221, Republic of China Taiwan, New Taipei City, Taiwan
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at BTL Inc.?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 7131.01Active
Accredited standards
20Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC 61000 series
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
ISO/IEC 17025:2017; IEC 17025; IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2
IEC 61000-3-2; IEC 61000-3-12; IEC 61000-3-3; IEC 61000-3-11; ANSI C63
IEC 61000-3-2; IEC 61000-3-12; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
ISO/IEC 17025:2017; IEC 17025; IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2
IEC 61000-3-2; IEC 61000-3-12; IEC 61000-3-3; IEC 61000-3-11; ANSI C63
IEC 61000-3-2; IEC 61000-3-12; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-2; IEC 61000-3-12; IEC 61000-3-3; IEC 61000-3-11; ANSI C63
IEC 61000-3-2; IEC 61000-3-12; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phaseCertificate says EN 61000-3-12. Probably the same standard; not checked against the EN document.
IEC 61000-3-2; IEC 61000-3-12; IEC 61000-3-3; IEC 61000-3-11; ANSI C63
IEC 61000-3-2; IEC 61000-3-12; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
ISO/IEC 17025:2017; IEC 17025; IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2
IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6
IEC 61000-3-2; IEC 61000-3-12; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-6-1; IEC 61000-6-2
IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-6-1; IEC 61000-6-2
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-6-1; IEC 61000-6-2
IEC 61000-4-11; IEC 61000-4-34; IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3
IEC 61000-4-34Name not checked yet
IEC 61000-4-11; IEC 61000-4-34; IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-6-1; IEC 61000-6-2
IEC 61000-4-11; IEC 61000-4-34; IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-6-1; IEC 61000-6-2
IEC 61000-4-11; IEC 61000-4-34; IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsCertificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.
IEC 61000-4-11; IEC 61000-4-34; IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3
IEC
IEC 62209-1Name not checked yet
IEC 62311; IEC 62209-1; IEC 62209-2; IEC 62479; IEEE 62209-1528
IEC 62209-2Name not checked yet
IEC 62311; IEC 62209-1; IEC 62209-2; IEC 62479; IEEE 62209-1528
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)Certificate says EN 62311. Probably the same standard; not checked against the EN document.
IEC 62311; IEC 62209-1; IEC 62209-2; IEC 62479; IEEE 62209-1528
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 62311; IEC 62209-1; IEC 62209-2; IEC 62479; IEEE 62209-1528
Other standards
ANSI C63Name not checked yet
ANSI C63; ANSI/TIA-603; ANSI/TIA-102
Scope as published by A2LA
9 lines
ISO/IEC 17025
Active7131.01
The scope document we hold says it is valid until 2027-11-30.
Labs with overlapping accredited scope in Taiwan
- Bureau Veritas Consumer Products Services (Hong Kong) Ltd., Taoyuan BranchTaoyuan CityA2LAShares 2 accredited test methodsANSI C63IEC 61000-4-2
- SGS TaiwanTaoyuanA2LAShares 2 accredited test methodsIEC 61000-4-2IEC 61000-4-6
- Bureau Veritas Consumer Products Services (Hong Kong) Ltd., NEW TAIPEI CITY BRANCHNew Taipei CityA2LAShares 1 accredited test methodANSI C63
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.