Bureau Veritas Consumer Products Services (Hong Kong) Ltd., NEW TAIPEI CITY BRANCH
No. 47-2, 14th Ling, Chia Pau Village, Lin Kou District, New Taipei City , 24442, Republic of China Taiwan, New Taipei City, Taiwan
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Bureau Veritas Consumer Products Services (Hong Kong) Ltd., NEW TAIPEI CITY BRANCH?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 4327.02Active
Accredited standards
14Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC 61000 series
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-6; IEC 61000-4-11
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-6; IEC 61000-4-11
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-6; IEC 61000-4-11
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-6; IEC 61000-4-11
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-6; IEC 61000-4-11
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsCertificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.
ISO/IEC 17025:2017; IEC 17025; IEC 55014-1; IEC 55015; IEC 61000-6-3
IEC 61326 series
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61204-3; IEC 61326-1; IEC 61326-2-1; IEC 61326-2-2; IEC 61326-2-6
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61204-3; IEC 61326-1; IEC 61326-2-1; IEC 61326-2-2; IEC 61326-2-6
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61204-3; IEC 61326-1; IEC 61326-2-1; IEC 61326-2-2; IEC 61326-2-6
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
IEC 61204-3; IEC 61326-1; IEC 61326-2-1; IEC 61326-2-2; IEC 61326-2-6
Other standards
ANSI C63Name not checked yet
ANSI C63
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: EmissionCertificate says IEC 55014-1. Probably the same standard; not checked against the EN document.
ISO/IEC 17025:2017; IEC 17025; IEC 55014-1; IEC 55015; IEC 61000-6-3
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipmentCertificate says IEC 55015. Probably the same standard; not checked against the EN document.
ISO/IEC 17025:2017; IEC 17025; IEC 55014-1; IEC 55015; IEC 61000-6-3
IEC 61204-3Name not checked yet
IEC 61204-3; IEC 61326-1; IEC 61326-2-1; IEC 61326-2-2; IEC 61326-2-6
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active4327.02
The scope document we hold says it is valid until 2027-12-31.
Accredited scope, certificate 4327.02
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | Electrical Testing | ISO/IEC 17025:2017; IEC 17025; IEC 55014-1; IEC 55015; IEC 61000-6-3 | - | to 40 GHz |
| 2 | Electrical Testing | IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-6; IEC 61000-4-11 | - | - |
| 3 | Electrical Testing | IEC 61204-3; IEC 61326-1; IEC 61326-2-1; IEC 61326-2-2; IEC 61326-2-6 | Information Technology Equipment (ITE); Industrial and Light Industrial Equipment; Home Appliance; Medical (ISM) Equipment; Telecommunication Network Equipment; Multimedia Equipment; Radio Equipment and Services; Maritime Navigation and Radio Communication Equipment; Railway Applications; Airborne Equipment; Radio Apparatus Capable of Receiving Television Broadcasting | - |
| 4 | electrical | ANSI C63 | - | to 40000 MHz |
| 5 | Dimensional Metrology | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.