FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Taiwan

Bureau Veritas Consumer Products Services (Hong Kong) Ltd., NEW TAIPEI CITY BRANCH

No. 47-2, 14th Ling, Chia Pau Village, Lin Kou District, New Taipei City , 24442, Republic of China Taiwan, New Taipei City, Taiwan

A2LA|4327.02ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
5
Standards
14
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Bureau Veritas Consumer Products Services (Hong Kong) Ltd., NEW TAIPEI CITY BRANCH?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
4327.02Active

Accredited standards

14

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 61000 series

IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
As written on the certificate · Line 2 (A2LA 4327.02)

IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-6; IEC 61000-4-11

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
As written on the certificate · Line 2 (A2LA 4327.02)

IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-6; IEC 61000-4-11

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 2 (A2LA 4327.02)

IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-6; IEC 61000-4-11

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
As written on the certificate · Line 2 (A2LA 4327.02)

IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-6; IEC 61000-4-11

IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
As written on the certificate · Line 2 (A2LA 4327.02)

IEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-6; IEC 61000-4-11

IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsCertificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 1 (A2LA 4327.02)

ISO/IEC 17025:2017; IEC 17025; IEC 55014-1; IEC 55015; IEC 61000-6-3

IEC 61326 series

IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
As written on the certificate · Line 3 (A2LA 4327.02)

IEC 61204-3; IEC 61326-1; IEC 61326-2-1; IEC 61326-2-2; IEC 61326-2-6

IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
As written on the certificate · Line 3 (A2LA 4327.02)

IEC 61204-3; IEC 61326-1; IEC 61326-2-1; IEC 61326-2-2; IEC 61326-2-6

IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
As written on the certificate · Line 3 (A2LA 4327.02)

IEC 61204-3; IEC 61326-1; IEC 61326-2-1; IEC 61326-2-2; IEC 61326-2-6

IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
As written on the certificate · Line 3 (A2LA 4327.02)

IEC 61204-3; IEC 61326-1; IEC 61326-2-1; IEC 61326-2-2; IEC 61326-2-6

Other standards

ANSI C63Name not checked yet
As written on the certificate · Line 4 (A2LA 4327.02)

ANSI C63

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: EmissionCertificate says IEC 55014-1. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 1 (A2LA 4327.02)

ISO/IEC 17025:2017; IEC 17025; IEC 55014-1; IEC 55015; IEC 61000-6-3

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipmentCertificate says IEC 55015. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 1 (A2LA 4327.02)

ISO/IEC 17025:2017; IEC 17025; IEC 55014-1; IEC 55015; IEC 61000-6-3

IEC 61204-3Name not checked yet
As written on the certificate · Line 3 (A2LA 4327.02)

IEC 61204-3; IEC 61326-1; IEC 61326-2-1; IEC 61326-2-2; IEC 61326-2-6

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

4327.02

The scope document we hold says it is valid until 2027-12-31.

View scope

Accredited scope, certificate 4327.02

LineDisciplineMethodMatrixRange
1Electrical TestingISO/IEC 17025:2017; IEC 17025; IEC 55014-1; IEC 55015; IEC 61000-6-3-to 40 GHz
2Electrical TestingIEC 61000-3-11; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-6; IEC 61000-4-11--
3Electrical TestingIEC 61204-3; IEC 61326-1; IEC 61326-2-1; IEC 61326-2-2; IEC 61326-2-6Information Technology Equipment (ITE); Industrial and Light Industrial Equipment; Home Appliance; Medical (ISM) Equipment; Telecommunication Network Equipment; Multimedia Equipment; Radio Equipment and Services; Maritime Navigation and Radio Communication Equipment; Railway Applications; Airborne Equipment; Radio Apparatus Capable of Receiving Television Broadcasting-
4electricalANSI C63-to 40000 MHz
5Dimensional MetrologyISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.