AnTek Certification
No. 21, Gongjian Rd. Keelung, 20647 Taiwan (Laboratory Address), 7F, No. 351, Yangguang St. Taipei, 11491 Taiwan (Organization Address), Keelung City, 20647, Republic of China Taiwan, Keelung City, Taiwan
Visit website- Accredited standards
- 10
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 10 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-13
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
MIL-STD-810 Method 500; IEC 60068-2-13; MIL-STD-810 Method 501; IEC 60068-2-2; MIL-STD-810 Method 502; IEC 60068-2-1; MIL-STD-810 Method 503; IEC 60068-2-14; MIL-STD-810 Method 507; IEC 60068-2-78; MIL-STD-810 Method 509; IEC 60068-2-11; MIL-STD-810 Method 514; IEC 60068-2-6; IEC 60068-2-64; MIL-STD-810 Method 516; IEC 60068-2-27; IEC 60068-2-31; MIL-STD-810 Method 528; IEC 60068-2-6
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
2 lines
ISO/IEC 17025
Active7594.01
The scope document we hold says it is valid until 2027-08-31.
Accredited scope, certificate 7594.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | MIL-STD-810 Method 500; IEC 60068-2-13; MIL-STD-810 Method 501; IEC 60068-2-2; MIL-STD-810 Method 502; IEC 60068-2-1; MIL-STD-810 Method 503; IEC 60068-2-14; MIL-STD-810 Method 507; IEC 60068-2-78; MIL-STD-810 Method 509; IEC 60068-2-11; MIL-STD-810 Method 514; IEC 60068-2-6; IEC 60068-2-64; MIL-STD-810 Method 516; IEC 60068-2-27; IEC 60068-2-31; MIL-STD-810 Method 528; IEC 60068-2-6 | Battery | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
ANTEK CERTIFICATION INC.
Keelung City, R.O.C Taiwan
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 23rd day of February 2026.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 7549.01
Valid to August 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.