Conrad Kacsik Instrument Systems

30925 Aurora Rd., 44139, Solon, OH, United States

Visit website
A2LA 1385.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
1
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 1 standard number and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM E145

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

1385.01

The scope document we hold says it is valid until 2027-12-31.

View scope

Accredited scope, certificate 1385.01

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1385.01) Revised 02/26/2026 Page 2 of 4 Parameter/Equipment Range CMC 2 (±) Comments Electrical Calibration of mV Thermocouple Sources 3 – Type B Type C Type E Type J Type K Type N Type R Type S Type T (649 to 1649) °C (537 to 2204) °C (-270 to 1000) °C (-210 to 760) °C (-270 to 1372) °C (-270 to 1300) °C (0 to 1767) °C (0 to 1767) °C (-270 to 400) °C 1.2 °C 0.93 °C 0.14 °C 0.12 °C 0.13 °C 0.14 °C 0.28 °C 0.28 °C 0.13 °C HP 3458A opt 002, Kaye ice point, Omega T/C half junctions Electrical Calibration of Thermocouple Indicators 3 – Type B Type C Type E Type J Type K Type N Type R Type S Type T (649 to 1649) °C (537 to 2204) °C (-270 to 1000) °C (-200 to 760) °C (-200 to 1372) °C (-200 to 1300) °C (-50 to 1767) °C (-50 to 1767) °C (-250 to 400) °C 1.2 °C 0.93 °C 0.14 °C 0.12 °C 0.13 °C 0.14 °C 0.28 °C 0.28 °C 0.13 °C Fluke 5520A HP 3458A opt 002, Kaye ice point, Omega T/C half junctions II. Mechanical Parameter/Equipment Range CMC 2 (±) Comments Vacuum Gauges – All Gases (1ꞏ10 -6 to 1ꞏ10-4) Torr (1ꞏ10 -4 to 1x10-3) Torr (1ꞏ10-3 to 1ꞏ10-2) Torr (1ꞏ10-2 to 7.5ꞏ10 2) Torr 8.1 x 10-2 Torr 8.3 x 10 -2 Torr 1.1 x 10-1 Torr 6.4 x 10 -2 Torr Televac MM200/Televac CC- 10
3ASTM E145; AMS-2750Furnaces & OvensSee scope document
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1385.01) Revised 02/26/2026 Page 4 of 4 Parameter/Equipment Range CMC 2, 5 (±) Comments Infrared Calibrators – Measure (50 to 250) °C (260 to 1100) °C (1101 to 1204) °C 0.08 °C 0.72 °C 1.7 °C CELABS R5T185L RTD, HP 3458A opt 002 Ectron 1140A, primary T/C type S Contact thermometry method IV. Time and Frequency Parameter/Equipment Range CMC 2 (±) Comments Stopwatches & Timers Up to 86 400 s 0.15 s HP 5334B ________________________________ 1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined usi ng the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading a fixed floor specification. 5 The type of instrument or material being calib rated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
5ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.