Conrad Kacsik Instrument Systems
30925 Aurora Rd., 44139, Solon, OH, United States
Visit website- Accredited standards
- 1
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM E145
ASTM E145; AMS-2750
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active1385.01
The scope document we hold says it is valid until 2027-12-31.
Accredited scope, certificate 1385.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1385.01) Revised 02/26/2026 Page 2 of 4
Parameter/Equipment
Range CMC 2 (±) Comments
Electrical Calibration of
mV Thermocouple
Sources
3 –
Type B
Type C
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(649 to 1649) °C
(537 to 2204) °C
(-270 to 1000) °C
(-210 to 760) °C
(-270 to 1372) °C
(-270 to 1300) °C
(0 to 1767) °C
(0 to 1767) °C
(-270 to 400) °C
1.2 °C
0.93 °C
0.14 °C
0.12 °C
0.13 °C
0.14 °C
0.28 °C
0.28 °C
0.13 °C
HP 3458A opt 002,
Kaye ice point,
Omega T/C half
junctions
Electrical Calibration of
Thermocouple Indicators
3 –
Type B
Type C
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(649 to 1649) °C
(537 to 2204) °C
(-270 to 1000) °C
(-200 to 760) °C
(-200 to 1372) °C
(-200 to 1300) °C
(-50 to 1767) °C
(-50 to 1767) °C
(-250 to 400) °C
1.2 °C
0.93 °C
0.14 °C
0.12 °C
0.13 °C
0.14 °C
0.28 °C
0.28 °C
0.13 °C
Fluke 5520A
HP 3458A opt 002,
Kaye ice point,
Omega T/C half
junctions
II. Mechanical
Parameter/Equipment
Range CMC
2 (±) Comments
Vacuum Gauges – All Gases
(1ꞏ10
-6 to 1ꞏ10-4) Torr
(1ꞏ10
-4 to 1x10-3) Torr
(1ꞏ10-3 to 1ꞏ10-2) Torr
(1ꞏ10-2 to 7.5ꞏ10
2) Torr
8.1 x 10-2 Torr
8.3 x 10
-2 Torr
1.1 x 10-1 Torr
6.4 x 10
-2 Torr
Televac
MM200/Televac CC-
10 | ||
| 3 | ASTM E145; AMS-2750 | Furnaces & Ovens | See scope document |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1385.01) Revised 02/26/2026 Page 4 of 4
Parameter/Equipment
Range CMC 2, 5 (±) Comments
Infrared Calibrators –
Measure
(50 to 250) °C
(260 to 1100) °C
(1101 to 1204) °C
0.08 °C
0.72 °C
1.7 °C
CELABS R5T185L RTD, HP
3458A opt 002
Ectron 1140A, primary T/C
type S
Contact thermometry method
IV. Time and Frequency
Parameter/Equipment
Range CMC
2 (±) Comments
Stopwatches & Timers
Up to 86 400 s
0.15 s
HP 5334B
________________________________
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The stated measured values are determined usi ng the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading a fixed floor specification.
5 The type of instrument or material being calib rated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 5 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Keithley Primary StandardsSolon, OH · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Micro Laboratories, Inc.Mentor, OH · ~32 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Cleveland Specialty Inspection ServicesMentor, OH · ~34 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- All American Scales & CalibrationParis, OH · ~70 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hapeman ElectronicsStoneboro, PA · ~112 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.