United States

Renishaw

1001 Wesemann Drive, 60118, West Dundee, IL, United States

Visit website
A2LA 2707.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
2
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 2 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO 10360-2Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring machines (CMM) - Part 2: CMMs used for measuring linear dimensions
ISO 10360-5Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring systems (CMS) - Part 5: Coordinate measuring machines (CMMs) using single and multiple stylus contacting probing systems using discrete point and/or scanning measuring mode

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

2707.01

The scope document we hold says it is valid until 2027-06-30.

View scope

Accredited scope, certificate 2707.01

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ISO 10360-2; ISO 10360-5-See scope document
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2707.01) Revised 09/03/2025 Page 2 of 3 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Angular Accuracy – Measure (0 to 360)° 0.46 arcsec Laser interferometer II. Dimensional Testing1 Parameter/Equipment Range CMC2 (±) Comments One Dimensional5 – Fixed Length (Setting Gage Calibrator) (50 to 300) mm 0.85 µm Setting gage calibrator One Dimensional5 – Linear Displacement (Telescoping Ballbar) (-1 to 1) mm 0.40 µm Laser interferometer III. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Environmental Sensors – Air Temperature Material Temperature Air Pressure Relative Humidity (15 to 25) °C (15 to 25) °C (913 to 1031) mbar (25 to 75) % RH 0.070 °C (70 mK) 0.070 °C (70 mK) 0.9 mbar 4.3 % RH Reference sensors IV. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Optical Frequency of HeNe Lasers (473 612 629 to 473 613 461) MHz 5.9 MHz Reference laser ____________________________________________ 1 This laboratory offers commercial dimensional testing, calibration service , and field calibration service
0 to 360 °
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2707.01) Revised 09/03/2025 Page 3 of 3 where noted. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of Calibration and Measurement Capability , L is the numerical value of the nominal length of the device measured in millimeters. 5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration certificate. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
4ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1001 Wesemann Drive, West Dundee, IL, 60118, US

42.09808, -88.28286

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.