Renishaw
1001 Wesemann Drive, 60118, West Dundee, IL, United States
Visit website- Accredited standards
- 2
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 2 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO 10360-2Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring machines (CMM) - Part 2: CMMs used for measuring linear dimensions
ISO 10360-5Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring systems (CMS) - Part 5: Coordinate measuring machines (CMMs) using single and multiple stylus contacting probing systems using discrete point and/or scanning measuring mode
ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ISO 10360-2; ISO 10360-5
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active2707.01
The scope document we hold says it is valid until 2027-06-30.
Accredited scope, certificate 2707.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ISO 10360-2; ISO 10360-5 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2707.01) Revised 09/03/2025 Page 2 of 3
Parameter/Equipment
Range CMC2, 4, 6 (±) Comments
Angular Accuracy –
Measure
(0 to 360)°
0.46 arcsec
Laser interferometer
II. Dimensional Testing1
Parameter/Equipment Range CMC2 (±) Comments
One Dimensional5 –
Fixed Length
(Setting Gage Calibrator)
(50 to 300) mm
0.85 µm
Setting gage
calibrator
One Dimensional5 –
Linear Displacement
(Telescoping Ballbar)
(-1 to 1) mm
0.40 µm
Laser interferometer
III. Thermodynamics
Parameter/Equipment Range CMC2 (±) Comments
Environmental Sensors –
Air Temperature
Material Temperature
Air Pressure
Relative Humidity
(15 to 25) °C
(15 to 25) °C
(913 to 1031) mbar
(25 to 75) % RH
0.070 °C (70 mK)
0.070 °C (70 mK)
0.9 mbar
4.3 % RH
Reference sensors
IV. Time & Frequency
Parameter/Equipment Range CMC2 (±) Comments
Optical Frequency of
HeNe Lasers
(473 612 629 to
473 613 461) MHz
5.9 MHz
Reference laser
____________________________________________
1 This laboratory offers commercial dimensional testing, calibration service , and field calibration service | 0 to 360 ° |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2707.01) Revised 09/03/2025 Page 3 of 3
where noted.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of Calibration and Measurement Capability , L is the numerical value of the nominal
length of the device measured in millimeters.
5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration certificate.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- GraftelRoselle, IL · ~21 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- J. H. MetrologyRolling Meadows, IL · ~22 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Chicago, ILArlington Heights, IL · ~25 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- DicksonAddison, IL · ~31 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Martin Calibration, Inc dba Great Lakes Calibration,Suite E Addison, IL · ~31 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.