SGS-CSTC Standards Technical Services Co., Ltd. Suzhou Branch
3/4F, Building 1, LIANDONG U VALLEY, No.200 Xingpu Road, SIP, Suzhou, Jiangsu, People's Republic of China, Suzhou, Jiangsu, China
Visit website- Accredited standards
- 57
- A2LA certificates
- 3
- Sites in our directory
- 3
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 57 standard numbers and the 26 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC10
IEC 60312-1Vacuum cleaners for household use - Part 1: Dry vacuum cleaners - Methods for measuring the performance
IEC 61008-1
IEC 61683
IEC 61727
IEC 62116
IEC 62233Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure
IEC 62301
IEC 62752
IEC 62891
IEC 62955
IEC 60335 series8
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements+1 national
National versions in the same scope
AS/NZS 60335.1national version with changes
IEC 60335-2-2Household and similar electrical appliances - Safety - Part 2-2: Particular requirements for vacuum cleaners and water-suction cleaning appliances+1 national
National versions in the same scope
AS/NZS 60335.2.2national version with changes
IEC 60335-2-8Household and similar electrical appliances - Safety - Part 2-8: Particular requirements for shavers, hair clippers and similar appliances+1 national
National versions in the same scope
AS/NZS 60335.2.8identical to it
IEC 60335-2-10Household and similar electrical appliances - Safety - Part 2-10: Particular requirements for floor treatment machines and wet scrubbing machines+1 national
National versions in the same scope
AS/NZS 60335.2.10probably the same standard; matched by number only
IEC 60335-2-15+1 national
National versions in the same scope
AS/NZS 60335.2.15national version with changes
IEC 60335-2-23+1 national
National versions in the same scope
AS/NZS 60335.2.23national version with changes
IEC 60335-2-32
IEC 60335-2-69Household and similar electrical appliances - Safety - Part 2-69: Particular requirements for wet and dry vacuum cleaners, including power brush, for commercial use+1 national
National versions in the same scope
AS/NZS 60335.2.69probably the same standard; matched by number only
ISO7
ISO 5011Inlet air cleaning equipment for internal combustion engines and compressors - Performance testing
ISO 11155-1
ISO 12500-1Filters for compressed air - Test methods - Part 1: Oil aerosols
ISO 12500-3Filters for compressed air - Test methods - Part 3: Particulates
ISO 18562-2Biocompatibility evaluation of breathing gas pathways in healthcare applications - Part 2: Tests for emissions of particulate matter
ISO 29461-1Air intake filter systems for rotary machinery - Test methods - Part 1: Static filter elements
ISO 29461-3Air intake filter systems for rotary machinery - Test methods - Part 3: Mechanical integrity of filter elements
EN 1822 series4
EN 1822-1
EN 1822-2
EN 1822-3
EN 1822-5
IEC 61000 series4
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
ISO 29463 series4
ISO 29463-1High efficiency filters and filter media for removing particles in air - Part 1: Classification, performance, testing and marking
ISO 29463-2High-efficiency filters and filter media for removing particles in air - Part 2: Aerosol production, measuring equipment and particle-counting statistics
ISO 29463-3High-efficiency filters and filter media for removing particles in air - Part 3: Testing flat sheet filter media
ISO 29463-5High-efficiency filters and filter media for removing particles in air - Part 5: Test method for filter elements
EN3
EN 779
EN 13274-7
EN 50530
EN 50549 series3
EN 50549-1
EN 50549-2
EN 50549-10
IEC 61439 series3
IEC 61439-1
IEC 61439-2
IEC 61439-7
IEC 61851 series3
IEC 61851-1
IEC 61851-23
IEC 61851-24
IEC 62885 series3
IEC 62885-2Surface cleaning appliances - Part 2: Dry vacuum cleaners for household or similar use - Methods for measuring the performance
IEC 62885-4
IEC 62885-8
ISO 16890 series3
ISO 16890-1Air filters for general ventilation - Part 1: Technical specifications, requirements and classification system based upon particulate matter efficiency (ePM)
ISO 16890-2Air filters for general ventilation - Part 2: Measurement of fractional efficiency and air flow resistance
ISO 16890-3Air filters for general ventilation - Part 3: Determination of the gravimetric efficiency and the air flow resistance versus the mass of test dust captured
Other standards2
ASTM F1977Standard Test Method for Determining Initial, Fractional, Filtration Efficiency of a Vacuum Cleaner System
ASTM F2299
IEC 60335-2-69; EN 60335-2-69; AS/NZS 60335.2.69; IEC 60312-1; EN 60312-1; IEC 62885-2; GB/T38048.2; IEC 62885-4; EN IEC 62885-4; IEC/ASTM 62885-7; CSV EN IEC/ASTM 62885-7; IEC 62885-8; IEC 62233; EN 62233; IEC 60335-1; EN 60335-1; AS/NZS 60335.1; IEC 60335-2-2; EN 60335-2-2; AS/NZS 60335.2.2
IEC 61851-1; EN IEC 61851-1; IEC 61851-1:2010; EN 61851-1:2011; BS EN 61851-1:2011; BS EN IEC 61851-1; IEC 61851-1:2017/COR1:2023; EN IEC 61851-1:2019/AC:2023-12; PNS IEC 61851-1; IEC 61851-23:2014+COR1:2016; IEC 61851-23; EN 61851-23:2014+AC:2016-06; BS EN 61851-23:2014; PNS IEC 61851-23; IEC 61851-24:2014+COR1:2015; IEC 61851-24; EN 61851-24:2014+AC:2015; EN IEC 61851-24; BS EN 61851-24:2014; UL 2594; UL 2202; UL 2231-1; UL 2231-2; CSA C22.2 No. 280:22; CSA C22.2 No. 346:22; CSA C22.2 No. 281.1-12; CSA C22.2 No. 281.2-12; TR 25-1; TR 25-2; TR 25-3; TR 25-4; TR 136; IEC 62752:2016+A1:2018; IEC 62752; EN 62752:2016+A1:2020; EN IEC 62752; BS EN 62752:2016+A1:2020; BS EN IEC 62752; IEC 62955; IEC 61008-1:2010+A1:2012+A2:2013; EN 61008-1:2012+A1:2014+A12:2017; IEC 61439-1; EN IEC 61439-1; BS EN IEC 61439-1; IEC 61439-2; EN IEC 61439-2; BS EN IEC 61439-2; IEC 61439-7; EN IEC 61439-7; BS EN IEC 61439-7
IEC 61000-3-2; IEC 61000-3-12; IEC 61000-3-3; IEC 61000-3-11; IEC 61727; IEC 62116; IEC 61683; EN 50530; EN 50549-1; EN 50549-2
AHAM AC-1; AHAM AC-3; JEM 1467; SPS-KACA002-132; GB/T 18801; AHAM AC-7; IEC 60335-2-69; ISO 12500-1; ISO 12500-3; SEMI F38; UL 867; IEC 62301; ISO 18562-2; ASTM F2299; EN 13274-7; NIOSH TEB-APR-STP-0059; eCFR: Appendix FF to Subpart B of Part 430, Title 10; ANSI/AHAM AC-1; IEC 62301; UL 867
EREC G100; NC Code RfG; COMMISSION REGULATION (EU) 2016/631; PSE; PTPiREE; PEA; MEA; IEC TS 62910; BESF Grid Connection Code; The Saudi Arabian Distribution Code; PV Large Scale Technical Connection Standards; Battery Energy Storage System Standards for Connection; IEC 62891
IEC 60335-1; EN 60335-1; AS/NZS 60335.1; IEC 60335-2-2; EN IEC 60335-2-2; AS/NZS 60335.2.2; IEC 60335-2-10; EN 60335-2-10; AS/NZS 60335.2.10; IEC 60335-2-8; EN 60335-2-8; AS/NZS 60335.2.8; IEC 60335-2-15; EN 60335-2-15; AS/NZS 60335.2.15; IEC 60335-2-23; EN IEC 60335-2-23; AS/NZS 60335.2.23; IEC 60335-2-32; EN IEC 60335-2-32; AS NZS 60335.2.32
ASHRAE 52.2; IEC 60335-2-69 (Annex AA); ISO 11155-1; ISO 16890-2; ISO 16890-1; ISO 16890-3; EN 779; EN 1822-1; EN 1822-2; EN 1822-3; EN 1822-5; IEST RP CC001; IEST RP CC007; IEST RP CC021; ISO 29463-1; ISO 29463-2; ISO 29463-3; ISO 29463-5; EN ISO 29463-3; EN ISO 29463-5; JEM 1467; ASTM F1977; IEC 62885-2; IEC 62885-4; IEC 60335-2-69 (Annex AA); ISO 5011; SAE J2554; ISO 29461-1; ISO 29461-3
EN 50549-10; EREC G98; EREC G99; Technical Guidelines for Power Generating Units and Systems PART 3 (TG3); VDE-AR-N 4105; VDE V 0124-100; DIN V VDE V 0126-1-1; DEWA; CEI 0-21; CEI 0-16; NRS 097-2-1; RPPS
Read from the A2LA scope documents we downloaded on 2026-03-14 and 2026-10-27. Register refreshed 2026-11-06.
Scope as published by A2LA
12 lines
ISO/IEC 17025
Active6181.02
The scope document we hold says it is valid until 2027-08-31.
ISO/IEC 17025
Active6181.03
The scope document we hold says it is valid until 2027-08-31.
ISO/IEC 17025
Active6181.04
The scope document we hold says it is valid until 2027-08-31.
Other Locations
2 other sites in this organization
Labs with overlapping accredited scope in China
- Attestation of Global Compliance (Shenzhen) Co.,GuangdongA2LAShares 2 accredited test methodsIEC 60335-1IEC 61000-3-2
- Bay Area Compliance Laboratories Corp.(Xiamen)XiaMenA2LAShares 1 accredited test methodIEC 61000-3-2
- Bestway Compliance Co.,DongguanA2LAShares 1 accredited test methodIEC 61000-3-2
- Bureau Veritas CPS Technology Services (Guangzhou) Co.,Guangdong,A2LAShares 1 accredited test methodIEC 60335-1
- Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchDongguan City, Guangdong ProvinceA2LAShares 1 accredited test methodIEC 61000-3-2
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.