SIMCO Electronics - Denver

389 Disc Dr., 80503, Longmont, CO, United States

Visit website
A2LA 1395.24ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
12
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 12 scope lines.

A2LA certificate 1395.24 · 12 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 1 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.24) 11/24/2025 Page 2 of 11 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage – Generate3 Up to 330 mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1000) V 16 µV/V + 0.78 µV 9.2 µV/V + 1.6 µV 10 µV/V + 16 µV 15 µV/V + 120 µV 15 µV/V + 1.2 mV Fluke 5520A DC Voltage – Measure3 (0 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V* 11 µV/V + 0.3 µV 5.3 µV/V + 0.3 µV 5.1 µV/V + 0.5 µV 8.5 µV/V + 30 µV 8.9 µV/V + 100 µV* HP 3458A, opt 2 *add 12 (Vin/1000)2 parts in 106 to all Vin > 100 DC Current – Generate3 Clamp Meters3 (0 to 330) µA 330 µA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 330 mA to 1.1 A (1.1 to 3) A (3 to 11) A (11 to 20) A (10 to 1000) A 0.012 % + 0.02 µA 79 µA/A + 0.04 µA 79 µA/A + 0.19 µA 80 µA/A + 32 µA 0.016 % + 32 µA 0.030 % + 32 µA 0.040 % + 0.39 mA 0.078 % + 0.59 mA 0.82 % + 0.029 A Fluke 5520A Fluke 5500A/coil & 5520A/SC1100 DC Current – Measure3 (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 2) A (2 to 20) A (20 to 100) A 0.003 µA/A + 0.8 nA 0.03 µA/A + 5 nA 0.3 µA/A + 50 nA 0.005 mA/A + 500 nA 0.15 mA/A + 10 µA 0.003 A 0.058 A 0.29 A HP 3458A, opt 2 Current shunt, HP 3458A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.24) 11/24/2025 Page 3 of 11 Parameter/Equipment Range CMC2, 4 (±) Comments Resistance – Generate3 Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (0.33 to 1.1) GΩ 33 µΩ/Ω + 0.0078 Ω 26 µΩ/Ω + 1.2 mΩ 27 µΩ/Ω + 1.2 mΩ 30 µΩ/Ω + 1.6 mΩ 27 µΩ/Ω + 1.6 mΩ 30 µΩ/Ω + 1.6 mΩ 34 µΩ/Ω + 78 mΩ 27 µΩ/Ω + 0.78 Ω 22 µΩ/Ω + 0.32 Ω 27 µΩ/Ω + 7.8 Ω 30 µΩ/Ω + 7.8 Ω 48 µΩ/Ω + 120 Ω 0.010 % + 200 Ω 0.02 % + 1.9 kΩ 0.039 % + 2.4 kΩ 0.23 % + 78 kΩ 1.2 % + 390 kΩ Fluke 5520A/SC1100 Resistance – Measure3 (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (100 to 1000) MΩ 25 µΩ/Ω + 50 µΩ 21 µΩ/Ω + 0.5 mΩ 12 µΩ/Ω + 0.5 mΩ 12 µΩ/Ω + 50 mΩ 14 µΩ/Ω + 90 mΩ 20 µΩ/Ω + 2 Ω 59 µΩ/Ω + 100 Ω 0.061 % + 1 kΩ 32 % + 10 kΩ HP 3458A, opt 2 Electrical Simulation of Thermocouples Indicating Devices – Generate & Measure3 Type E Type J (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C 0.42 °C 0.18 °C 0.17 °C 0.18 °C 0.21 °C 0.24 °C 0.18 °C 0.17 °C 0.18 °C 0.22 °C Fluke 5520A/SC1100
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.24) 11/24/2025 Page 4 of 11 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples Indicating Devices – Generate & Measure 3 (cont) Type K Type T (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.28 °C 0.19 °C 0.18 °C 0.24 °C 0.33 °C 0.50 °C 0.22 °C 0.18 °C 0.17 °C Fluke 5520A/SC1100 Parameter/Range Frequency CMC2, 4 (±) Comments Capacitance – Generate3 (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 600 Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.55 % + 7.8 pF 0.44 % + 7.8 pF 0.42 % + 7.8 pF 0.24 % + 7.8 pF 0.23 % + 78 pF 0.24 % + 78 pF 0.24 % + 0.23 nF 0.24 % + 0.8 nF 0.23 % + 2.3 nF 0.24 % + 7.8 nF 0.34 % + 24 nF 0.39 % + 78 nF 0.39 % + 0.24 µF 0.37 % + 0.8 µF 0.37 % + 2.3 µF 0.37 % + 8 µF 0.59 % + 24 µF 0.86 % + 78 µF Fluke 5520A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.24) 11/24/2025 Page 5 of 11 Parameter/Equipment Range CMC2, 5 (±) Comments Oscilloscope3 – Amplitude – DC Signal: 50 Ω 1 MΩ Amplitude – Square Wave3: 50 Ω 1 MΩ Bandwidth Time Marker Rise Time 1 mV to 6.6 V 1 mV to 130 V 1 mV p-p to 6.6 Vp-p, 10 Hz to 100 kHz 1 mVp-p to 130 Vp-p, 10 Hz to 100 kHz 5 mV to 5.5 V: 50 kHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 4 mV to 3.5 V: (600 to 1100) MHz 5 s to 50 ms 1 ns to 20 ms 1 kHz to 2 MHz: (200 to 300) ps (2 to 10) MHz: (200 to 350) ps 0.2 % + 40 µV 0.05 % + 40 µV 0.23 % + 31 µV 0.16 % + 31 µV 1.8 % + 0.23 mV 2.8 % + 0.23 mV 3.2 % + 0.23 mV 4.7 % + 0.23 mV 5.5 % + 0.23 mV 60 µs/s 2.1 µs/s 82 ps 82 ps Fluke 5520A/SC1100
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.24) 11/24/2025 Page 6 of 11 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.064 % + 4.7 µV 0.019 % + 4.7 µV 0.023 % + 4.7 µV 0.082 % + 4.7 µV 0.28 % + 9.3 µV 0.63 % + 39 µV 0.024 % + 6.2 µV 0.013 % + 6.2 µV 0.014 % + 6.2 µV 0.029 % + 6.2 µV 0.063 % + 25 µV 0.16 % + 55 µV 0.024 % + 39 µV 0.014 % + 47 µV 0.017 % + 47 µV 0.025 % + 39 µV 0.056 % + 97 µV 0.2 % + 470 µV 0.025 % + 510 µV 0.014 % + 470 µV 0.02 % + 470 µV 0.03 % + 470 µV 0.072 % + 1.3 mV 0.017 % + 1.6 mV 0.017 % + 4.7 mV 0.022 % + 4.7 mV 0.03 % + 4.7 mV 0.17 % + 39 mV 0.025 % + 7.8 mV 0.021 % + 7.8 mV 0.025 % + 7.8 mV Fluke 5520A/SC1100
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.24) 11/24/2025 Page 7 of 11 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure3 (1 to 10) mV (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.05 % + 3 µV 0.037 % + 1.1 µV 0.048 % + 1.1 µV 0.12 % + 1.1 µV 0.61 % + 1.1 µV 4.7 % + 2 µV 110 µV/V + 4 µV 91 µV/V + 2 µV 0.017 % + 2 µV 0.036 % + 2 µV 0.096 % + 2 µV 0.76 % + 10 µV 1.2 % + 10 µV 83 µV/V + 40 µV 84 µV/V + 20 µV 0.016 % + 20 µV 0.035 % + 20 µV 0.093 % + 20 µV 0.35 % + 100 µV 1.2 % + 100 µV 85 µV/V + 0.4 mV 84 V/V + 0.2 mV 0.017 % + 0.2 mV 0.035 % + 0.2 mV 0.093 % + 0.2 mV 0.35 % + 1.0 mV 1.2 % + 1.0 mV 0.02 % + 4 mV 0.01 % + 2 mV 0.024 % + 2.5 mV 0.041 % + 2.5 mV 0.14 % + 2.5 mV 0.05 % + 40 mV 0.05 % + 20 mV 0.07 % + 20 mV 0.14 % + 20 mV 0.35 % + 20 mV HP 3458A, opt 2
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.24) 11/24/2025 Page 8 of 11 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate3 (29 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1.0 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1.0 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1.0 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1.0 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1.0 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1.0 kHz (1 to 5) kHz (5 to 10) kHz 45 Hz to 1.0 kHz (1 to 5) kHz 45 Hz to 1.0 kHz (1 to 5) kHz 0.16 % + 80 nA 0.12 % + 80 nA 0.1 % + 80 nA 0.23 % + 0.12 µA 0.62 % + 0.16 µA 1.3 % + 0.31 µA 0.16 % + 0.12 µA 0.1 % + 0.12 µA 0.08 % + 0.12 µA 0.16 % + 0.16 µA 0.39 % + 0.23 µA 0.8 % + 0.47 µA 0.14 % + 1.6 µA 0.071 % + 1.6 µA 0.034 % + 1.6 µA 0.064 % + 1.6 µA 0.16 % + 2.4 µA 0.32 % + 3.1 µA 0.14 % + 16 µA 0.071 % + 16 µA 0.034 % + 16 µA 0.079 % + 39 µA 0.16 % + 78 µA 0.32 % + 0.16 mA 0.14 % + 78 µA 0.039 % + 78 µA 0.039 % + 78 µA 0.47 % + 0.78 mA 2.0 % + 4 mA 0.14 % + 78 µA 0.15 % + 78 µA 0.055 % + 78 µA 0.47 % + 0.78 mA 2.0 % + 4 mA 0.083 % + 1.6 mA 2.4 % + 1.6 mA 0.12 % + 4 mA 2.4 % + 4 mA Fluke 5520A/SC1100
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.24) 11/24/2025 Page 9 of 11 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate3 (cont) Clamp Meters: Up to 500 A (500 to 1000) A (45 to 440) Hz (45 to 440) Hz 1.2 % + 0.078 A 1.2 % + 0.19 A Fluke 5500A/coil & 5520A LCOMP OFF AC Current – Measure3 (5 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 2) A (2 to 20) A* (20 to 200) A* 45 Hz to 5 kHz 45 Hz to 5 kHz 45 Hz to 5 kHz 45 Hz to 5 kHz 45 Hz to 5 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 0.07 % + 0.03 µA 0.07 % + 0.2 µA 0.07 % + 2 µA 0.07 % + 20 µA 0.12 % + 0.2 mA 0.14 % + 0.2 mA 0.17 % + 2 mA 0.17 % + 2 mA HP 3458A, opt2 * w/ Valhalla 2575A III. Mechanical Parameter/Equipment Range CMC2, 7 (±) Comments Torque –Measure, Wrenches & Drivers3 (5 to 50) ozf∙in (5 to 25) lbf∙in (25 to 250) lbf∙in (25 to 250) lbf∙ft 0.77 % Indicated Value 0.77 % Indicated Value 0.77 % Indicated Value 0.77 % Indicated Value Check-line ITI & ITF-System
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.24) 11/24/2025 Page 10 of 11 IV. Time & Frequency Parameter/Equipment Range CMC2, 5, 7 (±) Comments Frequency – Generate Equipment3 Rubidium Standard 10 MHz Up to 80 MHz Up to 26.5 GHz (1 x 10 -9) Hz + 0.58R (1 x 10 -9) Hz + 1 µHz (1.2 x 10-9) Hz + 0.58R Pendulum Instruments GPS-12R Rubidium, Agilent 33120A & 83630B Frequency – Measure3 Up to 12.4 GHz (1 x 10-9) Hz + 0.58R Rubidium, Agilent 53132A, HP53131A Tachometers – Noncontact 3 (10 to 200 000) rpm 0.19 mrpm/rpm + 0.58R HP 33250A phase locked to GPS-12R _______________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 5 In the statement of CMC, R is the resolution of the unit under test; L is the numerical value of the nominal length of the device measured in inches. In the statement of CMC, the value is defined as the percentage of reading. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.24) 11/24/2025 Page 11 of 11 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
12ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.