DEHN SE DEHN Test Centre
Hans-Dehn-Straße 1, 92318, Neumarkt i.d.OPf., Germany
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at DEHN SE DEHN Test Centre?
Claim this profile to keep it accurate.
Register record
- DAKKSRefreshed
- D-PL-22157-01-00Active
- D-PL-22157-01-01Active
Accredited standards
11Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC 62561 series
IEC 62561-1Name not checked yet
DIN EN 50539-11: 2013/A1:2015-09; VDE 0675-39-11 2013/A1:2015-09; IEC 61643-31:2018; DIN EN 61643-31:2021; VDE 0675-6-31:2021; IEC 62305-1:2010; DIN EN 62305-1:2011; VDE 0185-305-1:2011; IEC 62561-1:2012; DIN EN 62561-1:2013; VDE 0185-561-1:2013; IEC 62561-1:2017; DIN EN 62561-1:2017; VDE 0185-561-1:2017; IEC 62561-2:2018 + Cor1:2019
IEC 62561-2Name not checked yet
DIN EN 50539-11: 2013/A1:2015-09; VDE 0675-39-11 2013/A1:2015-09; IEC 61643-31:2018; DIN EN 61643-31:2021; VDE 0675-6-31:2021; IEC 62305-1:2010; DIN EN 62305-1:2011; VDE 0185-305-1:2011; IEC 62561-1:2012; DIN EN 62561-1:2013; VDE 0185-561-1:2013; IEC 62561-1:2017; DIN EN 62561-1:2017; VDE 0185-561-1:2017; IEC 62561-2:2018 + Cor1:2019
DIN EN 62561-2:2019; VDE 0185-561-2:2019; IEC 62561-3:2012; DIN EN 62561-3:2013; VDE 0185-561-1:2013; IEC 62561-3:2017; DIN EN 62561-3:2018; VDE 0185-561-1:2018; IEC 62561‐4:2017; DIN EN 62561‐4 (VDE 0185‐561‐4):2018; IEC 62561-5:2017; DIN EN 62561-5:2018; VDE 0185-561-5: 2018; IEC/TS 62561-08:2018; DIN IEC/TS 62561-8:2019; VDE 0185-561-8:2019; IEC 61400-24:2010
IEC 62561-3Name not checked yet
DIN EN 62561-2:2019; VDE 0185-561-2:2019; IEC 62561-3:2012; DIN EN 62561-3:2013; VDE 0185-561-1:2013; IEC 62561-3:2017; DIN EN 62561-3:2018; VDE 0185-561-1:2018; IEC 62561‐4:2017; DIN EN 62561‐4 (VDE 0185‐561‐4):2018; IEC 62561-5:2017; DIN EN 62561-5:2018; VDE 0185-561-5: 2018; IEC/TS 62561-08:2018; DIN IEC/TS 62561-8:2019; VDE 0185-561-8:2019; IEC 61400-24:2010
IEC 62561-4Name not checked yet
DIN EN 62561-2:2019; VDE 0185-561-2:2019; IEC 62561-3:2012; DIN EN 62561-3:2013; VDE 0185-561-1:2013; IEC 62561-3:2017; DIN EN 62561-3:2018; VDE 0185-561-1:2018; IEC 62561‐4:2017; DIN EN 62561‐4 (VDE 0185‐561‐4):2018; IEC 62561-5:2017; DIN EN 62561-5:2018; VDE 0185-561-5: 2018; IEC/TS 62561-08:2018; DIN IEC/TS 62561-8:2019; VDE 0185-561-8:2019; IEC 61400-24:2010
IEC 62561-5Name not checked yet
DIN EN 62561-2:2019; VDE 0185-561-2:2019; IEC 62561-3:2012; DIN EN 62561-3:2013; VDE 0185-561-1:2013; IEC 62561-3:2017; DIN EN 62561-3:2018; VDE 0185-561-1:2018; IEC 62561‐4:2017; DIN EN 62561‐4 (VDE 0185‐561‐4):2018; IEC 62561-5:2017; DIN EN 62561-5:2018; VDE 0185-561-5: 2018; IEC/TS 62561-08:2018; DIN IEC/TS 62561-8:2019; VDE 0185-561-8:2019; IEC 61400-24:2010
IEC 61643 series
IEC 61643-11Name not checked yet
IEC 61643-11:2011; DIN EN 61643-11 VDE 0675-6-11:2013-04; DIN EN 61643-11: 2019 VDE 0675-6-11:2019; IEC 61643-12:2008; DIN CLC/TS 61643-12: 2010 VDE V 0675-6-12: 2010; IEC37A/287/ CDV:2016; E DIN EN 61643-12: 2017 E VDE V 0675-6-12: 2017
IEC 61643-12Name not checked yet
IEC 61643-11:2011; DIN EN 61643-11 VDE 0675-6-11:2013-04; DIN EN 61643-11: 2019 VDE 0675-6-11:2019; IEC 61643-12:2008; DIN CLC/TS 61643-12: 2010 VDE V 0675-6-12: 2010; IEC37A/287/ CDV:2016; E DIN EN 61643-12: 2017 E VDE V 0675-6-12: 2017
IEC 61643-31Name not checked yet
DIN EN 50539-11: 2013/A1:2015-09; VDE 0675-39-11 2013/A1:2015-09; IEC 61643-31:2018; DIN EN 61643-31:2021; VDE 0675-6-31:2021; IEC 62305-1:2010; DIN EN 62305-1:2011; VDE 0185-305-1:2011; IEC 62561-1:2012; DIN EN 62561-1:2013; VDE 0185-561-1:2013; IEC 62561-1:2017; DIN EN 62561-1:2017; VDE 0185-561-1:2017; IEC 62561-2:2018 + Cor1:2019
Other standards
EN 50539-11Name not checked yet
DIN EN 50539-11: 2013/A1:2015-09; VDE 0675-39-11 2013/A1:2015-09; IEC 61643-31:2018; DIN EN 61643-31:2021; VDE 0675-6-31:2021; IEC 62305-1:2010; DIN EN 62305-1:2011; VDE 0185-305-1:2011; IEC 62561-1:2012; DIN EN 62561-1:2013; VDE 0185-561-1:2013; IEC 62561-1:2017; DIN EN 62561-1:2017; VDE 0185-561-1:2017; IEC 62561-2:2018 + Cor1:2019
IEC 61400-24Name not checked yet
DIN EN 62561-2:2019; VDE 0185-561-2:2019; IEC 62561-3:2012; DIN EN 62561-3:2013; VDE 0185-561-1:2013; IEC 62561-3:2017; DIN EN 62561-3:2018; VDE 0185-561-1:2018; IEC 62561‐4:2017; DIN EN 62561‐4 (VDE 0185‐561‐4):2018; IEC 62561-5:2017; DIN EN 62561-5:2018; VDE 0185-561-5: 2018; IEC/TS 62561-08:2018; DIN IEC/TS 62561-8:2019; VDE 0185-561-8:2019; IEC 61400-24:2010
DIN EN 61400-24: 2011; VDE 0127-24:2011; IEC 61400-24:2019; DIN EN IEC 61400-24:2020; VDE 0127-24:2020; CLC/TS 50703-1:2021; CLC/TS 50703-2:2020
IEC 62305-1Name not checked yet
DIN EN 50539-11: 2013/A1:2015-09; VDE 0675-39-11 2013/A1:2015-09; IEC 61643-31:2018; DIN EN 61643-31:2021; VDE 0675-6-31:2021; IEC 62305-1:2010; DIN EN 62305-1:2011; VDE 0185-305-1:2011; IEC 62561-1:2012; DIN EN 62561-1:2013; VDE 0185-561-1:2013; IEC 62561-1:2017; DIN EN 62561-1:2017; VDE 0185-561-1:2017; IEC 62561-2:2018 + Cor1:2019
Scope as published by DAKKS
5 lines
ISO/IEC 17025
ActiveD-PL-22157-01-00
Accredited scope, certificate D-PL-22157-01-00
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | - | - |
| 2 | electrical | IEC 61643-11:2011; DIN EN 61643-11 VDE 0675-6-11:2013-04; DIN EN 61643-11: 2019 VDE 0675-6-11:2019; IEC 61643-12:2008; DIN CLC/TS 61643-12: 2010 VDE V 0675-6-12: 2010; IEC37A/287/ CDV:2016; E DIN EN 61643-12: 2017 E VDE V 0675-6-12: 2017 | - | - |
| 3 | electrical | DIN EN 50539-11: 2013/A1:2015-09; VDE 0675-39-11 2013/A1:2015-09; IEC 61643-31:2018; DIN EN 61643-31:2021; VDE 0675-6-31:2021; IEC 62305-1:2010; DIN EN 62305-1:2011; VDE 0185-305-1:2011; IEC 62561-1:2012; DIN EN 62561-1:2013; VDE 0185-561-1:2013; IEC 62561-1:2017; DIN EN 62561-1:2017; VDE 0185-561-1:2017; IEC 62561-2:2018 + Cor1:2019 | - | - |
| 4 | electrical | DIN EN 62561-2:2019; VDE 0185-561-2:2019; IEC 62561-3:2012; DIN EN 62561-3:2013; VDE 0185-561-1:2013; IEC 62561-3:2017; DIN EN 62561-3:2018; VDE 0185-561-1:2018; IEC 62561‐4:2017; DIN EN 62561‐4 (VDE 0185‐561‐4):2018; IEC 62561-5:2017; DIN EN 62561-5:2018; VDE 0185-561-5: 2018; IEC/TS 62561-08:2018; DIN IEC/TS 62561-8:2019; VDE 0185-561-8:2019; IEC 61400-24:2010 | - | - |
| 5 | electrical | DIN EN 61400-24: 2011; VDE 0127-24:2011; IEC 61400-24:2019; DIN EN IEC 61400-24:2020; VDE 0127-24:2020; CLC/TS 50703-1:2021; CLC/TS 50703-2:2020 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-22157-01-01
Accredited scope, certificate D-PL-22157-01-01
No scope items available
Location
Labs with overlapping accredited scope in Germany
- Chemisches Institut Burkon Partnerschaft - Partnerschaft von HandelschemikernNürnberg · ~26 kmDAKKSShares 1 accredited test methodEN ISO 9001
- Siemens Energy Global GmbH & Co. KG Materialprüflabor Siemens Trafowerk NürnbergNürnberg · ~31 kmDAKKSShares 1 accredited test methodEN ISO 9001
- Lynexo DeutschlandNürnberg · ~33 kmDAKKSShares 1 accredited test methodEN ISO 9001
- Bureau Veritas Consumer Products Services GermanyNürnberg · ~33 kmDAKKSShares 1 accredited test methodEN ISO 9001
- Forschung und Materialprüfung Nürnberg WilhelmNürnberg · ~35 kmDAKKSShares 1 accredited test methodEN ISO 9001
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.