Registers refreshed 2026-11-08.See refresh dates
Poland

Firma Doradcza ISOTOP s.c. A. Wilczyńska-Piliszek, S.Piliszek

ul. Gen. J. Sowińskiego 12/6, 80-143, Gdańsk, Poland

PCA AB 1749ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
15
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 15 standard numbers and the 10 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO7
ISO 4869-2Acoustics - Hearing protectors - Part 2: Estimation of effective A-weighted sound pressure levels when hearing protectors are worn
ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
ISO 7243Ergonomics of the thermal environment - Assessment of heat stress using the WBGT (wet bulb globe temperature) index
ISO 7730Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
ISO 11079Ergonomics of the thermal environment - Determination and interpretation of cold stress when using required clothing insulation (IREQ) and local cooling effects
Other standards8
EN 458
EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidance

Certificate says EN 14253+A1:2011. Probably the same standard; not checked against the EN document.

PN-83/E-04040.03
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
PN-Z-01339
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05Ochrona czystości powietrza - Oznaczanie frakcji wdychalnej aerozolu na stanowiskach pracy metodą grawimetryczną
PN-Z-04508:2022-05

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.

Scope as published by PCA

6 lines
PCA

ISO/IEC 17025

Active

AB 1749

The scope document we hold says it is valid until 2028-04-14.

View on PCA

Accredited scope, certificate AB 1749

LineMethodMatrixRange
1-Air
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1749 Scope of accreditation No. AB 1749 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No. AB 1749 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 8 z/of 30.04.2025 KIEROWNIK DZIAŁU AKREDYTACJI BADAŃ EMISJI W ŚRODOWISKU MARCIN BEKAS Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1749 z dnia 15.04.2020 r. Cykl akredytacji od 25.03.2024 r. do 14.04.2028 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No. AB 1749 of 15.04.2020 Accreditation cycle from 25.03.2024 to 14.04.2028 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No 8, 30.04.2025 1/7 Nazwa i adres / Name and address Firma Doradcza ISOTOP s.c. A. Wilczyńska-Piliszek, S. Piliszek ul. gen. J. Sowińskiego 4/6, 80-143 Gdańsk Instytut Analiz Środowiska ul. gen. J. Sowińskiego 12/6, 80-143 Gdańsk Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: − C/33 − G/33 − G/34 − N/33/P − P/33 − Badania chemiczne - powietrze / Chemical tests – air − Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czyn- niki szkodliwe i uciążliwe – hałas, hałas ultradźwiękowy, oświetlenie, drgania, mikroklimat, wyda- tek energetyczny, środki ochrony osobistej) / Tests concerning environmental engineering (envi- ronmental and climatic) - working environment (harmful and nuisance factors – noise, ultrasonic noise, lighting, vibration, microclimate, energy expenditure, personal protection equipment) − Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas, oświetlenie) / Tests concerning environmental engineering (environ- mental and climatic) - general environment (physical factors – noise, lighting) − Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - po- wietrze) / Tests of physical properties and sampling - working environment (harmful factors - air) − Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze) / Sampling - working envi- ronment (harmful factors - air) Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB-07, available at PCA website www.pca.gov.pl AB 1749
-
2PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN 458:2016-06; PN-EN ISO 4869-2:2018-12; PN-EN ISO 9612:2011; PN-Z-01339:2020-12; Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706)Workplace environment27 to 137 dB
3PN-EN 14253+A1:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11Workplace environment0.03 to 25 m/s2
4PN-83/E-04040.03; PN-EN ISO 7730:2006+Ap2:2016-04; PN-EN ISO 7243:2018-01+Ap2:2020-04; PN-EN ISO 11079:2008; PB-02Workplace environmentSee scope document
5PN-Z-04008-7:2002+Az1:2004; PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08Air0.11 to 30 mg/m3
6Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130Air0.0063 to 0.25 mg/m3

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Gen. J. Sowińskiego 12/6, Gdańsk, 80-143, PL

54.42880, 18.79833

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.