ELEMENT MATERIALS TECHNOLOGY DENVER – LONGMONT
1601 Dry Creek Drive, Suite 2000, 80503, Longmont, CO, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at ELEMENT MATERIALS TECHNOLOGY DENVER – LONGMONT?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 2582.02Active
Certificates and scope
1ISO/IEC 17025
Active2582.02
The scope document we hold says it was valid until 2026-07-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 2582.02
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | mechanical | ASTM D4169; BellCore GR-63-CORE 5.4.2, 5.4.3; IEC 68-2-59, Test Fe; IEC 68-2-34, Test Fd; IEC 68-2-35, Test Fda; IEC 68-2-6, Test Fc; JESD22 B103B; MIL-STD-810E, Method 514.4, 519.4; MIL-STD-810F, Method 514.5, 519.5; MIL-STD-810G, Method 514.6, 519.6; MIL STD-810H, Methods 514, 519; MIL-STD-167-1 (A SHIPS); MIL-STD-202G, Method 201A, 204D, 214A; MIL-STD-883G, Method 2005.2, 2007.3, 2026; MIL-STD-883H, Method 2005.2, 2007.3, 2026; MIL-STD-1344A, Method 2005.1; RTCA DO-160D, E, F, G, Sec. 8.0; RTCA DO-227 6/23/1995, Sec. 2.3.1; SAE J1455, Sec. 4.10; SAE J1211, Sec. 4.7; UN ST/SG/AC.10/11 Rev. 5, Para. 38.3.4.3; ASTM D4728; ASTM D999; MIL STD-810H, Methods 526 | aircraft components; automotive components; marine components; coatings; packaging and containers; electronics; consumer goods | 1 to 3000 Hz |
| 2 | mechanical | IEC 68-2-27, Test Ea; IEC 68-2-29, Test Eb; JESD22 B104C Conditions A, C, D, E; MIL-STD-810E, Method 516.4; MIL-STD-810F, Method 516.5; MIL-STD-810G, Method 516.6; MIL STD-810H, Method 516; MIL-STD-202G, Method 213B; MIL-STD-883G, Method 2002.4; MIL-STD-883H, Method 2002.5; MIL-STD-1344A, Method 2004.1; RTCA DO-160D, E, F, G, Sec. 7.2; RTCA DO-227 6/23/1995, Sec. 2.3.2; SAE J1455, Sec. 4.11; SAE J1211, Sec. 4.8; UN ST/SG/AC.10/11 Rev. 5, Para. 38.3.4.4; MIL-STD-810E, Method 513.4; MIL-STD-810F, Method 513.5; MIL-STD-810G, Method 513.6; MIL STD-810H, Method 513; MIL STD-202G, Method 212A; MIL-STD-1344A, Method 2011.1; RTCA DO-160D, E, F, G, Sec. 7.3; BellCore GR-63-CORE, Sec. 5.1.1.1 and 5.1.1.2; IEC 68-2-1 Test A; IEC 68-2-2, Test B; JESD 22, Sec. A104C; MIL-STD-810E, Method 501.3, 502.3; MIL-STD-810F, Method 501.4, 502.4; MIL-STD-810G, Method 501.5, 502.5; MIL-STD-810E, Method 503.3, 520.1; MIL-STD-810F, Method 503.4, 520.2; MIL-STD-810G, Method 503.5, 520.3; MIL STD-810H, Methods 501; 502; 503; MIL-STD-202G, Method107G; MIL STD-883G, H, Method 1010.8; MIL-STD-1344A, Method 1003.1; RTCA DO-160D, E, F, G, Sec. 5.0; RTCA DO-227 6/23/1995, Sec. 2.3.3; SAE J1455, Sec. 4.1; SAE J1211, Sec. 4.1; UN ST/SG/AC.10/11 Rev. 5, Para. 38.3.4.2; RTCA DO-160D, E, F, G, Sec. 4; ASTM D4169; ASTM D4332 | - | -70 to 150 ºC |
| 3 | materials | BellCore GR-63-CORE 5.1.1.3 and 5.1.2; IEC 68-2-30, Test Db; MIL-STD-810E, Method 507.3; MIL-STD810F, Method 507.4; MIL-STD-810G, Method 507.5; MIL STD-810H, Method 507; MIL-STD-202G, Method 103B, 106G; MIL-STD-883G, H, Method 1004.7; MIL-STD-1344A, Method 1002.2; RTCA DO-160D, E, F, G, Sec. 6.0; RTCA DO-227 6/23/1995, Sec. 2.3.6; SAE J1455, Sec. 4.2; SAE J1211, Sec. 4.2; ASTM B117; GM 9540P (2013); IEC 68-2-52, Test Kb; MIL-STD-810E, Method 509.3; MIL-STD-810F, Method 509.4; MIL-STD-810G, Method 509.5; MIL STD-810H, Method 509; MIL-STD-202G, Method 101E; MIL-STD-883G, H, Method 1009.8; MIL-STD-1344A, Method 1001.1; NEMA 250, Sec. 5.8 and 5.9; RTCA DO-160D, E, F, G, Sec. 14.0; SAE J1455, Sec. 4.3; SAE J2334; SAE J1211, Sec. 4.3; ASTM D1654; ASTM D3359; MIL-STD-810E, Method 500.3; MIL-STD-810F, Method 500.4; MIL-STD-810G, Method 500.5; MIL STD-810H, Method 500; MIL-STD-202G, Method 105C; MIL-STD-202 E, F, and G Method 213; MIL-STD-883G, H, Method 1001.1; MIL-STD-1344A, Method 1011; SAE J1455, Sec. 4.9; SAE J1211, Sec. 4.6; UN ST/SG/AC 10/11 Rev. 5 Para. 38.3.4.1; RTCA DO-160 D, E, F, G, Sec. 4.0; RTCA/DO-160; EN 60601-1-11; ASTM D4169 | - | 5 to 95 % RH |
| 4 | mechanical | ASTM D6653; MIL-STD-810E, Method 500.3; MIL-STD-810F, Method 500.4; MIL-STD-810G, Method 500.5; MIL STD-810H, Method 500; RTCA DO-160D; RTCA DO-160E; RTCA DO-160F; RTCA DO-160G, Sec. 4.6; RTCA DO-227 6/23/1995, Sec. 2.3.4 and 2.3.5; MIL-STD-810E, Method 520.1; MIL-STD-810F, Method 520.2; MIL-STD-810G, Method 520.3; MIL STD-810H, Method 520; ASTM D4169; BellCore GR-63-CORE, Sec. 5.3; ASTM D5276; MIL-STD-810; IEC 60529, Sec. IP5X; IEC 60529, Sec. IP6X; MIL-STD-810F, Sec. 510.4; IEC 60529, Sec. IP X3; IEC 60529, Sec. IP X4; IEC 60529, Sec. IP X5; IEC 60529, Sec. IP X6; IEC 60529, Sec. IP X7; IEC 60529, Sec. IP X8; IEC 60529, Sec. IP-x1; IEC 60529, Sec. IP-x2; MIL-STD-810E, Method 512.3; MIL-STD-810F, Method 512.4; MIL-STD-810G, Method 512.5; MIL-STD-810H, Method 512; NEMA 250, Sec. 5.7; RTCA DO-160F, Sec. 10.0; SAE J1211, Sec. 4.4 | - | -1500 to 70000 ft |
| 5 | mechanical | MIL-STD-810E, Method 521.1; MIL-STD-810F, Method 521.2; MIL-STD-810G, Method 521.3; MIL-STD-810H, Method 521; NEMA 250, Sec. 5.6; RTCA DO-160D, E, F, G, Sec. 24, Cat. A & C; ASTM G154; IEC 60529, Sec. IPX5, IPX6, IP-1x, 2x, 3x, 4x; Qualmark Guideline 9.0; ISO 20653 IP-x9K; ASTM D4169; ASTM D642; ASTM D880; ASTM D6344; ASTM D6179 | - | - |
| 6 | mechanical | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- EUROFINS ELECTRICAL AND ELECTRONIC TESTING NASanta Clara, CA · ~1,492 kmA2LAShares 2 accredited test methodsASTM B117ASTM D4169
- National Institute for Aviation Research (NIAR) - Environmental TestWichita, KS · ~725 kmA2LAShares 1 accredited test methodASTM B117
- DDL, Inc.Eden Prairie, MN · ~1,085 kmA2LAShares 1 accredited test methodASTM D4169
- Element Materials Technology Dallas – Plano WestPlano, TX · ~1,093 kmA2LAShares 1 accredited test methodASTM B117
- Element Materials Technology MinneapolisMinneapolis, MN · ~1,105 kmA2LAShares 1 accredited test methodASTM B117
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.