Metallurgical Solutions
331 East Helena Street, 45404, Dayton, OH, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Metallurgical Solutions?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 2037.01Active
Certificates and scope
1ISO/IEC 17025
Active2037.01
The scope document we hold says it is valid until 2027-02-28.
Accredited scope, certificate 2037.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | mechanical | ISO/IEC 17025:2017; ASTM E18; ASTM F606/F606M; ASTM E10; ASTM E384; ASTM E92; ASTM E23; ASTM A370; ASTM E8/8M; ASTM B557; ASTM E517; ASTM E646; ASTM C633; ASTM E190; ASTM E290; ASTM A90; SAE J423; ASM Metals Handbook Vol. 9 | automotive components, metals, alloys, and coatings | -40 to 95 °F |
| 2 | materials | MSI PWI #38; ASTM A892; ASTM E3; ASTM B487; ASTM E45 (Method A); ASTM A262 (Method A); MSI PWI #35; ASTM E1077; ASTM E112; ASTM E340; ASTM E407; ASTM E1351; ASTM E986; ASTM A751; E415; E1086; E1999; E1251; E2994; ASTM E1085; E572; E2465; E539; ASTM E1019; E1941; E1409; E1447; ASME IX; AWS D1.1/D1.1M; AWS D1.2/D1.2M; AWS D1.6/D1.6M; AWS D1.9/D1.9M; AWS D17.1/D17.1M; ASM Metals Handbook Vol. 11; ASTM E620; E678; E860; E2332 | Low Alloy Steel (Al, C, Cr, Cu, Mn, Mo, Nb, Ni, P, S, Si, Ti, V); Cast Iron (C, Cr, Cu, Mn, Mo, Ni, P, S, Si, Ti, V); High Alloy Steel (C, Co, Cr, Cu, Mn, Mo, Nb, Ni, P, S, Ti, W, V); Aluminum (Cr, Cu, Fe, Mn, Ni, Si, Ti, V, Zn, Mg); Titanium (Al, Cr, Fe, Mo, V); Low Alloy Steel (Al, Cr, Cu, Mn, Mo, Nb, Ni, P, S, Si, Ti, V); High Alloy Steel (Al, Cr, Cu, Mn, Mo, Nb, Ni, P, S, Si, Ti, V, W); Nickel (Al, Co, Cr, Cu, Fe, Mn, Mo, Nb, Ti, P); Titanium (Al, Cr, Fe, Mn, Mo, Nb, Sn, V, Zr) | - |
| 3 | mechanical | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- AFI IndustriesCarol Stream, IL · ~409 kmA2LAShares 2 accredited test methodsASTM E18ASTM E3
- Miami Valley Materials Testing CenterTipp City, OH · ~23 kmA2LAShares 1 accredited test methodASTM E3
- Metcut ResearchCincinnati, OH · ~78 kmA2LAShares 1 accredited test methodASTM E18
- Trescal, Inc. - Cincinnati, OHCincinnati, OH · ~78 kmA2LAShares 1 accredited test methodASTM E18
- EWI Lab ServicesColumbus, OH · ~104 kmA2LAShares 1 accredited test methodASTM E3
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.