Registers refreshed 2026-11-20.See refresh dates
United States

American Testing Services,

2000 Old Byers Road, 45342, Miamisburg, OH, United States

Visit website
A2LA 2855.01A2LA 2855.02ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
27
A2LA certificates
2
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 27 standard numbers and the 15 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM26
ASTM A262Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
ASTM A370Standard Test Methods and Definitions for Mechanical Testing of Steel Products
ASTM A488
ASTM A751
ASTM B163
ASTM B487Standard Test Method for Measurement of Metal and Oxide Coating Thickness by Microscopical Examination of Cross Section
ASTM E3Standard Guide for Preparation of Metallographic Specimens
ASTM E10Standard Test Method for Brinell Hardness of Metallic Materials
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM E23Standard Test Methods for Notched Bar Impact Testing of Metallic Materials
ASTM E112Standard Test Methods for Determining Average Grain Size
ASTM E190
Show all 26
ASTM E238
ASTM E340Standard Practice for Macroetching Metals and Alloys
ASTM E381
ASTM E384Standard Test Method for Microindentation Hardness of Materials
ASTM E407Standard Practice for Microetching Metals and Alloys
ASTM E415Standard Test Method for Analysis of Carbon and Low-Alloy Steel by Spark Atomic Emission Spectrometry
ASTM E1019Standard Test Methods for Determination of Carbon, Sulfur, Nitrogen, and Oxygen in Steel, Iron, Nickel, and Cobalt Alloys by Combustion and Inert Gas Fusion Techniques
ASTM E1077
ASTM E1086Standard Test Method for Analysis of Austenitic Stainless Steel by Spark Atomic Emission Spectrometry
ASTM E1251
ASTM E1268
ASTM E1508
ASTM E14761
ASTM E19161
Other standards1
ISO 15614-1Specification and qualification of welding procedures for metallic materials - Welding procedure test - Part 1: Arc and gas welding of steels and arc welding of nickel and nickel alloys

Read from the A2LA scope documents we downloaded on 2025-12-02 and 2026-10-27. Register refreshed 2026-11-20.

Scope as published by A2LA

8 lines
A2LA

ISO/IEC 17025

Active

2855.01

The scope document we hold says it is valid until 2027-07-31.

View scope

Accredited scope, certificate 2855.01

LineMethodMatrixRange
1ASTM E18; ASTM E10; ASTM E384, E92; ASTM A370, B557, E8; ASTM E190; ASTM E238; ASTM E23; AMS-STD-1595; API 1104; ASME IX; ASTM A488/A488M; AWS B2.1/B2.1M, B2.2/B2.2M, D1.1/D1.1M, D1.2/D1.2M, D1.3/D1.3M, D1.4/D1.4M, D1.5/D1.5M, D1.6/D1.6M, D1.7/D1.7M, D1.8/D1.8M, D1.9/D1.9M, D9.1/D9.1M, D14.1/D14.1M, D14.3/D14.3M, D14.4/D14.4M, D14.6/D14.6M, D15.1/D15.1M, D17.1/D17.1M; ISO 15614-1; BS EN287-1, 287-1, 288-3, 288-49; MIL-STD 1595A, 2219, 1261; NAVSEA S9074-AQ-GIB-010metals and metal components in Stainless Steel, Carbon Steel, Alloy Steel, Aluminum, Nickel, and Titanium Alloys0.1 to 60 klbs
2ASTM E3; ASTM E407; ASTM E340; ASTM E381; ASTM B487; ASTM E112; AMS 2759/7; SAE J423; GE P3TF19; ASTM E1077; NASM 8831; ASTM E1268; ASTM A262; AMS 5557; ASTM B163; ASTM A751; ASTM E415; ASTM E1086; ASTM E1251; ASTM E1019; ASTM E14761; ASTM E19161; ASTM E1508; ATS QP-10-817; ATS QP-10-816; ASM Metals HBK Vol 11Metals and Alloys; Plating; Tubing-
3ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA

ISO/IEC 17025

Active

2855.02

The scope document we hold says it is valid until 2027-07-31.

View scope

Accredited scope, certificate 2855.02

LineMethodMatrixRange
1ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994-100 to 19990 A
2-air; oil
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2855.02) 07/23/2025 Page 2 of 4 II. Magnetic Quantities Parameter/Equipment Range CMC2, 4 (±) Comments Gauss Meters – Magnetic Field (0 to 20) G (> 20 to 200) G (> 200 to 2000) G (> 2000 to 4000) G (> 4000 to 10 000) G 0.16 G 1.5 G 12 G 21 G 51 G Gauss meter with electric coil (DC stimulation) Gauss Meters – Magnetic Field3 (0 to 20) G (> 20 to 200) G 0.16 G 1.5 G Gauss meter with Helmholtz coil- DC stimulation) Gauss Meters – Magnetic Field (0 to 20) G (> 20 to 200) G (> 200 to 2000) G 0.67 G 7.1 G 68 G Gauss meter with electric coil (AC stimulation) Reference Magnets (0 to 20) G (> 20 to 200) G (> 200 to 2000) G (> 2000 to 4000) G (> 4000 to 10 000) G 0.16 G 1.5 G 12 G 21 G 51 G Gauss meter Magnetometer3 (0 to 5) G (> 5 to 10) G (> 10 to 20) G 0.19 G 0.32 G 0.61 G Helmholtz coil with Gauss meter III. Mechanical Parameter/Equipment Range CMC2, 6 (±) Comments Pressure – Measuring Equipment3 (0 to 100) psi (> 100 to 300) psi (> 300 to 1000) psi (> 1000 to 10 000) psi 0.14 psi 0.36 psi 0.65 psi 14 psi Master pressure gauges; nitrogen & air AC Hand Yoke3 10 lb + 1.3 % , Verification using model TB-10 10 lb weights
See scope document
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2855.02) 07/23/2025 Page 3 of 4 Parameter/Equipment Range CMC2, 6 (±) Comments DC Hand Yoke3 30 lb 50 lb + 1.3 % + 1.3 % Verification using model TB-10 10 lb weights IV. Optical Quantities Parameter/Equipment Range CMC2, 6 (±) Comments Light (Light Meters) – Measure3 UV (315 to 400) nm Visible Luminance Irradiance (0.1 to 100) mW/cm 2 (100 to 100 000) µW/cm2 Illuminance (5.4 to 5300) lux (0.5 to 500) ft•candle Luminance (100 to 200 000) ft•lambert 5 % of rdg 5 % of rdg 5 % of rdg 5 % of rdg 5 % of rdg Reference radiometer V. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Measure3 (0 to 400) °F (> 400 to 1200) °F 1.3 °F 3.5 °F Reference thermometer with type J & K thermocouples VI. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Duration Meter3 (0.5 to 6) s 0.04 s Duration timer
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2855.02) 07/23/2025 Page 4 of 4 Parameter/Equipment Range CMC2 (±) Comments Stopwatch/Timer3 (30 to 14 400) s 0.38 s Stopwatch 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the uncertainties achievable on a customer's site can normally be expected to be larger than the Best Measurement Capabilities (BMC) that the accredited laboratory has been assigned as Best Uncertainty on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance f or the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the calibration uncertainty being larger than the BMC. 4 In the terms of the CMC, G is Gauss. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 8 CMC values for Hand Yokes and Quick Break Testers are strictly derived from the calibration standards.
30 to 14400 s
5ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

2000 Old Byers Road, Miamisburg, OH, 45342, US

39.60176, -84.23939

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.