Registers refreshed 2026-11-08.See refresh dates
China

Shanghai ATBL Technology Co.,

5F., Unit 1, No 8, Free Trade One Life Science and Sci-Tech Industrial Park, No. 160, Basheng Road, Pudong New District,Shanghai City, China, Shanghai, People's Republic of China, Shanghai, China

Visit website
A2LA 6184.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
44
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 44 standard numbers and the 14 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI31
ETSI EN 300 086
ETSI EN 300 113
ETSI EN 300 220-1
ETSI EN 300 296
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 422-1
ETSI EN 300 422-2
ETSI EN 300 422-3
ETSI EN 300 422-4
ETSI EN 300 440
ETSI EN 301 357
Show all 31
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-3
ETSI EN 301 908-13
ETSI EN 301 908-14
ETSI EN 301 908-15
ETSI EN 302 208
ETSI EN 302 502
ETSI EN 303 340
ETSI EN 303 345-1
ETSI EN 303 345-2
ETSI EN 303 345-3
ETSI EN 303 345-4
ETSI EN 303 345-5
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
ETSI EN 303 609
IEC 61000 series7
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national

National versions in the same scope

AS/NZS 61000.3.2identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national

National versions in the same scope

AS/NZS 61000.3.3identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
Other standards6
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national

National versions in the same scope

AS/NZS CISPR 32identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

EN 220-2
EN 50566
FCC PART 15Radio Frequency Devices
RSS-210

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

6184.01

The scope document we hold says it is valid until 2027-05-31.

View scope

Accredited scope, certificate 6184.01

LineMethodMatrixRange
1CFR 47, FCC Part 15B; ANSI C63.4:2014; CFR 47, FCC Part 18; MP-5:1986; CISPR 32; EN 55032; BS EN 55032; AS/NZS CISPR 32; ICES-001; ICES-003; ICES-005; AS/NZS 61000.3.2; BS EN IEC 61000-3-2; IEC 61000-3-2; BS EN 61000-3-2; EN/IEC 61000-3-2; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; AS/NZS 61000.3.3; EN61000-4-2; IEC 61000-4-2; BS EN 61000-4-2; EN 61000-4-3; IEC 61000-4-3; BS EN IEC 61000-4-3; EN IEC 61000-4-3; EN 61000-4-4; IEC 61000-4-4; BS EN 61000-4-4; EN 61000-4-5; IEC 61000-4-5; BS EN 61000-4-5; EN 61000-4-6; IEC 61000-4-6; BS EN 61000-4-6--
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6184.01) 07/24/2025 Page 2 of 4 Test: Test Method(s) 1: Power Frequency Magnetic Field EN 61000-4-8; IEC 61000-4-8 Voltage Dips, Short Interruptions, and Voltage Variations Immunity Tests EN 61000-4-11; EN IEC 61000-4-11; IEC 61000-4-11; BS EN 61000-4-11; BS EN IEC 61000-4-11 Generic / Product Family / Product Specific EMC Standards CISPR 14-1; EN IEC 55014-1; BS EN 55014-1; AS/NZS CISPR 14.1; EN 55014-2; BS EN IEC 55014-2; AS/NZS CISPR 14.2; CISPR 15; EN IEC 55015; BS EN 55015; AS/NZS CISPR15; CISPR 11; EN 55011; BS EN 55011; AS CISPR 11; EN IEC 61000-6-1; IEC 61000-6-1; BS EN IEC 61000-6-1; AS/NZS 61000.6.1; EN IEC 61000-6-2; IEC 61000-6-2; BS EN IEC 61000-6-2; IEC 61000-6-3; EN 61000-6-3; BS EN IEC 61000-6-3; EN IEC 61000-6-3; AS/NZS 61000.6.3; EN IEC 61000-6-4; IEC 61000-6-4; BS EN IEC 61000-6-4; AS/NZS 61000.6.4; EN 61326-1; BS EN IEC 61326-1; IEC 61326-1; EN IEC 61326-1; EN 61326-2-1; BS EN IEC 61326-2-1; IEC 61326-2-1; EN IEC 61326-2-1; EN 61326-2-2; BS EN IEC 61326-2-2; IEC 61326-2-2; EN IEC 61326-2-2; EN 61326-2-6; BS EN IEC 61326-2-6; IEC 61326-2-6; EN IEC 61326-2-6; CISPR 35; EN 55035; BS EN 55035; IEC 61547; EN 61547; BS EN 61547; EN50130-4; BS EN 50130-4; ETSI EN 301 489-1, -3, -17, -19, -52; ETSI EN 300 386; EN 60601-1-2; IEC 60601-1-2; BS EN 60601-1-2 Radio CFR 47, FCC Part 15 C (using ANSI C63.10:2013 and/or ANSI C63.10:2020); CFR 47, FCC Part 15 E (using ANSI C63.10:2013, ANSI C63.10:2020, and/or FCC KDB Publication 905462 D02); CFR 47, FCC Parts 22, 24, 25, 27, 74, 90, 95, 97, 101 (using ANSI/TIA-603-E and ANSI C63.26:2015); CFR 47, Part 15 D (using ANSI C63.17:2013); RSS-GEN; RSS-119; RSS-123; RSS-130; RSS-131; RSS-132; RSS-133; RSS-137; RSS-139; RSS-140; RSS-192; RSS-195; RSS-197; RSS-199;
3RSS-210; RSS-213; RSS-216; RSS-220; RSS-247; RSS-248; RSS-310; ETSI EN 300 220-1; ETSI EN 220-2; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 300 440; ETSI EN 300 330; ETSI EN 301 511; ETSI EN 303 609; ETSI EN 302 502; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI EN 301 908-3; ETSI EN 301 908-13; ETSI EN 301 908-14; ETSI EN 301 908-15; ETSI EN 300 422-1; ETSI EN 300 422-2; ETSI EN 300 422-3; ETSI EN 300 422-4; ETSI EN 301 357; ETSI EN 300 086; ETSI EN 300 113; ETSI EN 300 296; ETSI EN 302 208; ETSI EN 303 413; ETSI EN 303 417; ETSI EN 303 345-1; ETSI EN 303 345-2; ETSI EN 303 345-3; ETSI EN 303 345-4; ETSI EN 303 345-5; ETSI EN 303 340; AS/NZS 4268; AS/CA S042.1; AS/ACIF S042.3; AS/CA S042.4; Article 2 Paragraph 1 of Item 8; Article 2 Paragraph 1 of Item 11-3, Annex 29; Article 2 Paragraph 1 of Item 11-7, Annex 29; Article 2 Paragraph 1 of Item 11-19, Annex 86; Article 2 Paragraph 1 of Item 21-3, Annex 82; Article 2 Paragraph 1 of Item 11-21; Article 2 Paragraph 1 of Item 11-19-2; Article 2 Paragraph 1 of Item 11-19-3; Article 2 Paragraph 1 of Item 19; Article 2 Paragraph 1 of Item 19-2; Article 2 Paragraph 1 of Item 19-2-2; Article 2 Paragraph 1 of Item 19-2-3; Article 2 Paragraph 1 of Item 19-3; Article 2 Paragraph 1 of Item 78; Article 2 Paragraph 1 of Item 79; Article 2 Paragraph 1 of Item 80; Article 2 Paragraph 1 of Item 1-12; EN 50566; BS EN 50566; IEEE/ANSI C95.1; IEEE/ANSI C95.3; FCC KDB 447498 D01-to 40 GHz
4ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; ANSI C63.10:2020; ANSI C63.17:2013; FCC KDB 905462 D02; ANSI C63.26-2015; ANSI/TIA-603-E-2016-to 40000 MHz
5

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited SHANGHAI ATBL TECHNOLOGY CO., LTD. Shanghai, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 24th day of July 2025. _ ______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6184.01 Valid to May 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .