Registers refreshed 2026-11-20.See refresh dates
China

BUREAU VERITAS LCIE CHINA COMPANY

Building 4, No. 518, Xinzhuan Road, Caohejing High-Tech Park, Songjiang District, Shanghai, China, Shanghai, People's Republic of China, Shanghai, China

Visit website
A2LA 2343.01A2LA 2343.02ISO/IEC 17025Register refreshed 2026-11-20
Part of the Bureau Veritas group: 82 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
103
A2LA certificates
2
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 103 standard numbers and the 33 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI31
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-1
ETSI EN 300 220-3-2
ETSI EN 300 220-4
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 386
ETSI EN 300 440
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-7
Show all 31
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-33
ETSI EN 301 489-34
ETSI EN 301 489-50
ETSI EN 301 489-52
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 302 065-1
ETSI EN 302 065-2
ETSI EN 302 065-3
ETSI EN 302 502
ETSI EN 303 340
ETSI EN 303 372-1
ETSI EN 303 372-2
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
ETSI EN 303 687
IEC28
IEC 60238
IEC 60328
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60598-2-3
IEC 60670-1
IEC 60670-22
IEC 60730-1Automatic electrical controls - Part 1: General requirements
IEC 60730-2-9
IEC 61439-7
IEC 61643-11
IEC 61960-3
IEC 62133-1
Show all 28
IEC 62133-2Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems
IEC 62233Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure

Certificate says EN 62233. Probably the same standard; not checked against the EN document.

IEC 62301
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)

Certificate says EN 62311. Probably the same standard; not checked against the EN document.

IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 62612
IEC 62619Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications
IEC 62620
IEC 62680-1-1
IEC 62717
IEC 62722-1
IEC 62722-2-1
IEC 62752
IEC 62891
IEC 62920
IEC 62955
IEC 60068 series10
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)

Certificate says EN 60068-2-6. Probably the same standard; not checked against the EN document.

IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-18Exclusion

Limits written next to it

IEC 60068-2-18 (except Rc-2 Pressure Submersion)

Exclusion. Written next to it on line 1 of A2LA certificate 2343.02.

IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock

Certificate says EN 60068-2-27. Probably the same standard; not checked against the EN document.

IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN6
EN 13032-4
EN 15194Some clauses

Limits written next to it

BS EN 15194 (Clause 4.2.15)

Some clauses. Written next to it on line 6 of A2LA certificate 2343.01.

EN 50385
EN 50604-1
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
CISPR5
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 11national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national

National versions in the same scope

AS/NZS CISPR 14.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55014-1, IEC 55014-1. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national

National versions in the same scope

AS/NZS CISPR 15national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55015, IEC 55015. Probably the same standard; not checked against the EN document.

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 22identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national

National versions in the same scope

AS/NZS CISPR 32identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032, IEC 55032. Probably the same standard; not checked against the EN document.

IEC 60086 series5
IEC 60086-1
IEC 60086-2
IEC 60086-3
IEC 60086-4
IEC 60086-5
IEC 61000 series4
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase

Certificate says EN 61000-3-12. Probably the same standard; not checked against the EN document.

EN 18031 series3
EN 18031-1
EN 18031-2
EN 18031-3
IEC 61851 series3
IEC 61851-1
IEC 61851-22
IEC 61851-23
IEC 62660 series3
IEC 62660-1
IEC 62660-2
IEC 62660-3
Other standards5
FCC KDB 905462 D02 (v02)
FCC PART 15Radio Frequency Devices
ISO 13849-1Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design
ISO 13849-2Safety of machinery - Safety-related parts of control systems - Part 2: Validation
XP C15-712-3

Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-20.

Scope as published by A2LA

12 lines
A2LA

ISO/IEC 17025

Active

2343.01

The scope document we hold says it is valid until 2027-08-31.

View scope
A2LA

ISO/IEC 17025

Active

2343.02

The scope document we hold says it is valid until 2027-08-31.

View scope

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.