Shenzhen LGT Test Service Co.,
Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, 518118, People's Republic of China, Shenzhen, China
Visit website- Accredited standards
- 114
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 114 standard numbers and the 42 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC22
IEC 60730-1Automatic electrical controls - Part 1: General requirements
IEC 60730-2-9
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61543
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 62040-1
IEC 62040-2Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
IEC 62115+1 national
National versions in the same scope
AS/NZS 62115probably the same standard; matched by number only
IEC 62209-1
IEC 62209-2
IEC 62232
Show all 22
IEC 62233Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure
IEC 62236-3-2
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national
National versions in the same scope
AS/NZS 62368.1national version with changes
IEC 62477-1+1 national
National versions in the same scope
AS IEC 62477.1probably the same standard; matched by number only
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 62493
IEC 62752
IEC 62920
IEC 62955
ETSI17
ETSI EN 300 386
ETSI EN 301 489-1Exclusion
Limits written next to it
ETSI EN 301 489-1 (excluding section 9.6)
ETSI EN 301 489-3
ETSI EN 301 489-4
ETSI EN 301 489-5
ETSI EN 301 489-6
ETSI EN 301 489-7
ETSI EN 301 489-8
ETSI EN 301 489-9
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-23
Show all 17
ETSI EN 301 489-33
ETSI EN 301 489-34
ETSI EN 301 489-50
ETSI EN 301 489-52
ETSI TS 103 701
IEC 61000 series17
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
Show all 17
IEC 61000-4-34
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments+1 national
National versions in the same scope
AS/NZS 61000.6.1national version with changes
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national
National versions in the same scope
AS/NZS 61000.6.2national version with changes
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
AS/NZS 61000.6.3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national
National versions in the same scope
AS/NZS 61000.6.4identical to it
IEC 60335 series15
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements+1 national
National versions in the same scope
AS/NZS 60335.1national version with changes
IEC 60335-2-2Household and similar electrical appliances - Safety - Part 2-2: Particular requirements for vacuum cleaners and water-suction cleaning appliances+1 national
National versions in the same scope
AS/NZS 60335.2.2national version with changes
IEC 60335-2-14+1 national
National versions in the same scope
AS/NZS 60335.2.14national version with changes
IEC 60335-2-15+1 national
National versions in the same scope
AS/NZS 60335.2.15national version with changes
IEC 60335-2-17+1 national
National versions in the same scope
AS/NZS 60335.2.17probably the same standard; matched by number only
IEC 60335-2-23+1 national
National versions in the same scope
AS/NZS 60335.2.23national version with changes
IEC 60335-2-24+1 national
National versions in the same scope
AS/NZS 60335.2.24probably the same standard; matched by number only
IEC 60335-2-29+1 national
National versions in the same scope
AS/NZS 60335.2.29national version with changes
IEC 60335-2-30
IEC 60335-2-32+1 national
National versions in the same scope
AS/NZS 60335.2.32identical to it
IEC 60335-2-41+1 national
National versions in the same scope
AS/NZS 60335.2.41probably the same standard; matched by number only
IEC 60335-2-45+1 national
National versions in the same scope
AS/NZS 60335.2.45probably the same standard; matched by number only
IEC 60335-2-65+1 national
National versions in the same scope
AS/NZS 60335.2.65identical to it
IEC 60335-2-97+1 national
National versions in the same scope
AS/NZS 60335.2.97probably the same standard; matched by number only
IEC 60335-2-107+1 national
National versions in the same scope
AS/NZS 60335.2.107probably the same standard; matched by number only
EN12
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50155Railway applications - Rolling stock - Electronic equipment
EN 50360
EN 50364
EN 50383
EN 50385
EN 50566
EN 50636-2-107
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 11national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: EmissionExclusion+1 national
Limits written next to it
EN IEC 55014-1 (excluding Discontinuous
EN IEC 55014-1 (excluding Discontinuous disturbances)
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard+1 national
National versions in the same scope
AS/NZS CISPR 14.2national version with changes
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national
National versions in the same scope
AS/NZS CISPR 15national version with changes
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+2 national
National versions in the same scope
AS/NZS CISPR 32identical to it
VCCI-CISPR 32probably the same standard; matched by number only
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC 61851 series5
IEC 61851-1
IEC 61851-21-2
IEC 61851-22
IEC 61851-23
IEC 61851-24
EN 18031 series3
EN 18031-1
EN 18031-2
EN 18031-3
IEC 60884 series3
IEC 60884-1Some clauses
Limits written next to it
IEC 60884-1 Clause 15 Interlocked socket-outlets
IEC 60884-2-5Some clauses
Limits written next to it
IEC 60884-2-5 Clause 15 Interlocked socket-outlets
IEC 60884-2-7Some clauses
Limits written next to it
IEC 60884-2-7 Clause 15 Interlocked socket-outlets
IEC 61010 series3
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
IEC 61010-2-201
IEC 62196 series3
IEC 62196-1+1 national
National versions in the same scope
AS/NZS 62196.1probably the same standard; matched by number only
IEC 62196-2+1 national
National versions in the same scope
AS/NZS IEC 62196.2probably the same standard; matched by number only
IEC 62196-3+1 national
National versions in the same scope
AS/NZS IEC 62196.3probably the same standard; matched by number only
IEC 63044 series3
IEC 63044-5-1
IEC 63044-5-2
IEC 63044-5-3
Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI/TIA-603-E
BS 1363-1
BS 1363-3
FCC PART 15Radio Frequency Devices
EN 60730-1; BS EN 60730-1; EN IEC 60730-1; EN 60730-2-9; BS EN 60730-2-9; EN IEC 60730-2-9; BS EN IEC 60730-2-9; IEC 62236-3-2:2018; EN 50155; BS EN 50155; EN 50121-3-2; BS EN 50121-3-2; EN 50121-4:2016; EN 50121-4; BS EN 50121-4; EN 55011; BS EN 55011; BS EN 55035; IEC 61547; BS EN IEC 61547; EN 61547; EN IEC 61547; BS EN 61547; EN IEC 61326-1; BS EN IEC 61326-1; BS EN IEC 61851-21-2; EN IEC 61851-21-2; IEC 61851-21-2; EN IEC 62040-2; BS EN IEC 62040-2; IEC 62920; EN 62920; EN IEC 62920; BS EN IEC 62920; IEC 61543; EN IEC 61543; BS EN IEC 61543; TR 25-1 (section 6.8.12); NRS 097-2-1 (section 4.9); IEC 62209-1; EN 62209-1; BS EN 62209-1; IEC 62209-2; EN 62209-2; BS EN 62209-2; EN 50360; BS EN 50360; EN 50566; BS EN 50566; IEEE Std 1528:2013; IEC/IEEE 62209-1528; IEEE Std C95.1; IEEE Std C95.3; RSS-102; RSS-102.SAR.MEAS; ACA Standard (Electromagnetic Radiation - Human Exposure); ARIB STD-T56; EN IEC/IEEE 62209-1528; BS EN IEC/IEEE 62209-1528; IEC 62232; EN IEC 62232; BS EN IEC 62232; FCC KDB 447498 D01 (v06); MIC Notices No. 88 Annex 79; IEC 62479; EN 62479; BS EN 62479; IEC 62311; EN 62311; EN IEC 62311; BS EN IEC 62311; EN 50364; BS EN 50364; EN 50383; BS EN 50383; EN 50385; BS EN 50385; EN 50663; BS EN 50663; EN 50665; BS EN 50665; EN 62232; BS EN 62232; EN 62233; AS/NZS 2772.2; EN 62493; BS EN 62493
CFR 47, FCC Part 15B (using ANSI C63.4:2014 2); CFR 47, FCC Part 18 (using MP-5:1986); AS/NZS CISPR 11; CISPR 11; EN IEC 55011; BS EN IEC 55011; J55032; J55015; J55011; EN IEC 55014-1 (excluding Discontinuous disturbances); AS/NZS CISPR 14.1 (excluding Discontinuous disturbances); CISPR 14-1 (excluding Discontinuous disturbances); BS EN IEC 55014-1 (excluding Discontinuous disturbances); J55014-1 (excluding Discontinuous disturbances); AS/NZS CISPR 15; CISPR 15; EN IEC 55015; BS EN IEC 55015; AS/NZS CISPR 32; CISPR 32; EN 55032; BS EN 55032; VCCI-CISPR 32; ICES-001; ICES-003; ICES-005; ICES-GEN; EN 61326-1; BS EN 61326-1; IEC/EN 60945; EN IEC 61000-3-2; BS EN IEC 61000-3-2; IEC 61000-3-12; EN 61000-3-12; BS EN 61000-3-12; IEC/EN 61000-3-3; BS EN 61000-3-3; IEC 61000-3-11; EN IEC 61000-3-11; BS EN IEC 61000-3-11
EN 60335-2-29; BS EN 60335-2-29; IEC 60335-2-30; EN 60335-2-30; BS EN 60335-2-30; IEC 60335-2-32; EN IEC 60335-2-32; BS EN IEC 60335-2-32; AS/NZS 60335.2.32; IEC 60335-2-41; EN IEC 60335-2-41; BS EN 60335-2-41; AS/NZS 60335.2.41; IEC 60335-2-45; EN 60335-2-45; BS EN 60335-2-45; AS/NZS 60335.2.45; AS/NZS 60335.2.65; IEC 60335-2-65; IEC 60335-2-97; EN IEC 60335-2-97; BS EN 60335-2-97; AS/NZS 60335.2.97; IEC 60335-2-107; EN 50636-2-107; BS EN 50636-2-107; AS/NZS 60335.2.107; AS/NZS 62368.1; IEC 62368-1; EN 62368-1; EN IEC 62368-1; BS EN IEC 62368-1; UL 62368-1; EN 61010-1; IEC 61010-1; BS EN 61010-1; IEC 61010-2-101; EN IEC 61010-2-101; BS EN IEC 61010-2-101; EN 61010-2-201; IEC 61010-2-201; BS EN IEC 61010-2-201; IEC 62040-1; EN IEC 62040-1; BS EN IEC 62040-1; AS/NZS 62040.1
AS IEC 62477.1; IEC 62477-1; EN IEC 62477-1; BS EN IEC 62477-1; IEC 62115; EN IEC 62115; BS EN IEC 62115; AS/NZS 62115; IEC 60884-1; IEC 60884-2-5; IEC 60884-2-7; UL 507; UL 1647; UL 982; UL 499; UL 998; UL 1278; UL 1261; UL 778
FCC CFR 47, FCC Parts 22, 24, 25, 27, 30, 73, 74, 80, 87, 90, 95, 96, 101; ANSI/TIA-603-E; ANSI C63.26:2015; TIA-102.CAAA-E; ISED RSS 119; RSS 130; RSS 131; RSS 132; RSS 133; RSS 135; RSS 137; RSS 139; RSS-140; RSS 192; RSS 195; RSS 197; RSS 199; RSS 210; RSS 213; RSS 215; RSS 216; RSS 220; RSS 236; RSS 247; RSS-248; RSS 310; RSS GEN; Australia AS/CA S042.1; AS/CA S042.4; AS/CA S042.5; AS/NZS 4268; Japan ARIB STD-T33; ARIB STD-T66; ARIB STD-T67; ARIB STD-T81; ARIB STD-T89; ARIB STD-T90; ARIB STD-T71; ARIB STD-T91; ARIB STD-T101; ARIB STD-T106; ARIB STD-T107; ARIB STD-T108; ARIB STD-T94 Fascicle 1; RCR STD-1; RCR STD-29; RCR STD-33; Japan Article 2 Paragraph 1 of Item 19, annex 43; Article 2 Paragraph 1 of Item 19-2, annex 44; Article 2 Paragraph 1 of Item 19-3, annex 45; Article 2 Paragraph 1 of Item 11-3 and 11-7, annex 29; Article 2 Paragraph 1 of Item 11-19, annex 86, and Item 54, annex 75; Article 2 Paragraph 1 of Item 11-30; Article 2 Paragraph 1 of Item 21-2, annex 81; Article 2 Paragraph 1 of Item 8, annex 22-1; Article 2 Paragraph 1 of Item 8, annex 22-8; Article 2 Paragraph 1 of Item 8, annex 22-12; Article 2 Paragraph 1 of Item 1-11, annex 6; Article 2 Paragraph 1 of Item 79; Article 2 Paragraph 1 of Item 80; Article 2 Paragraph 1 of Item 11-19-2; Article 2 Paragraph 1 of Item 11-19-3; Article 2 Paragraph 1 of Item 11-21; Article 2 Paragraph 1 of Item 21-3 annex 82; Article 2 Paragraph 1 of Item 11-34; Article 2 Paragraph 1 of Item 54-6; Article 2 Paragraph 1 of Item 72; Article 2 Paragraph 1 of Item 19-2-2; AS/NZS 62368.1; IEC 62368-1; EN 62368-1; EN IEC 62368-1; BS EN IEC 62368-1; BS 1363-1; BS 1363-3
IEC 62752; BS EN IEC 62752; EN IEC 62752; IEC 62955; BS IEC 62955; IEC 61851-1; EN IEC 61851-1; BS EN IEC 61851-1; IEC 61851-22; BS EN 61851-22; EN 61851-22; IEC 61851-23; AS IEC 61851.23; EN 61851-23; BS EN 61851-23; IEC 61851-24; AS IEC 61851.24; EN IEC 61851-24; BS EN IEC 61851-24; IEC 62196-1; BS EN 62196-1; EN 62196-1; AS/NZS 62196.1; IEC 62196-2; EN IEC 62196-2; BS EN IEC 62196-2; AS/NZS IEC 62196.2; IEC 62196-3; EN IEC 62196-3; BS EN IEC 62196-3; AS/NZS IEC 62196.3; IEC 62477-1; EN IEC 62477-1; BS EN IEC 62477-1; UL 2594; UL 2202; UL 2231-1; UL 2231-2; TR 25-2; TR 25-3; TR 25-4; TR 25-1; BS EN 60335-1; EN 60335-1; AS/NZS 60335.1; IEC 60335-1; IEC 60335-2-2; EN 60335-2-2; BS EN 60335-2-2; AS/NZS 60335.2.2; AS/NZS 60335.2.10; AS/NZS 60335.2.14; AS/NZS 60335.2.15; IEC 60335-2-14; AS/NZS 60335.2.15; IEC 60335-2-15; IEC 60335-2-17; EN 60335-2-17; BS EN 60335-2-17; AS/NZS 60335.2.17; IEC 60335-2-23; AS/NZS 60335.2.23; AS/NZS 60335.2.24; IEC 60335-2-24; AS/NZS 60335.2.29; IEC 60335-2-29
UL 867; UL 1310; UL 94; IEC 62752; BS EN IEC 62752; EN IEC 62752; IEC 62955; BS IEC 62955; IEC 61851-1; EN IEC 61851-1; BS EN IEC 61851-1; IEC 61851-22; BS EN 61851-22; EN 61851-22; IEC 61851-23; AS IEC 61851.23; EN 61851-23; BS EN 61851-23; IEC 62196-1; BS EN 62196-1; EN 62196-1; AS/NZS 62196.1; IEC 62196-2; EN IEC 62196-2; BS EN IEC 62196-2; AS/NZS IEC 62196.2; IEC 62196-3; EN IEC 62196-3; BS EN IEC 62196-3; AS/NZS IEC 62196.3; IEC 62477-1; EN IEC 62477-1; BS EN IEC 62477-1
EN 61000-4-2; IEC 61000-4-2; EN IEC 61000-4-2; BS EN IEC 61000-4-2; EN 61000-4-3; IEC 61000-4-3; EN IEC 61000-4-3; BS EN IEC 61000-4-3; EN 61000-4-4; IEC 61000-4-4; BS EN 61000-4-4; EN 61000-4-5; IEC 61000-4-5; BS EN 61000-4-5; EN 61000-4-6; IEC 61000-4-6; BS EN 61000-4-6; EN IEC 61000-4-6; BS EN IEC 61000-4-6; EN 61000-4-8; IEC 61000-4-8; BS EN 61000-4-8; EN 61000-4-11; IEC 61000-4-11; EN IEC 61000-4-11; BS EN IEC 61000-4-11; IEC 61000-4-34; EN 61000-4-34; BS EN 61000-4-34; EN 61000-4-13; BS EN 61000-4-13; EN 55035; CISPR 35; EN IEC 61000-6-1; BS EN IEC 61000-6-1; AS/NZS 61000.6.1; EN IEC 61000-6-2; BS EN IEC 61000-6-2; AS/NZS 61000.6.2; EN IEC 61000-6-3; BS EN IEC 61000-6-3; AS/NZS 61000.6.3; EN IEC 61000-6-4; BS EN IEC 61000-6-4; AS/NZS 61000.6.4; EN IEC 55014-2; AS/NZS CISPR 14.2; CISPR 14-2; BS EN IEC 55014-2; ETSI EN 301 489-1 (excluding section 9.6); ETSI EN 301 489-3; ETSI EN 301 489-4; ETSI EN 301 489-5; ETSI EN 301 489-6; ETSI EN 301 489-7; ETSI EN 301 489-8; ETSI EN 301 489-9; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-23; ETSI EN 301 489-34; ETSI EN 301 489-33; ETSI EN 301 489-50; ETSI EN 301 489-52; EN 50130-4; BS EN 50130-4; ETSI EN 300 386; EN IEC 63044-5-1; BS EN IEC 63044-5-1; EN IEC 63044-5-2; BS EN IEC 63044-5-2; EN IEC 63044-5-3; BS EN IEC 63044-5-3
EN 18031-1; BS EN 18031-1; EN 18031-2; BS EN 18031-2; EN 18031-3; BS EN 18031-3; ETSI TS 103 701
ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020+Cor 1:2023; ANSI C63.17:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015
ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015; FCC KDB 447498 D01 (v06)
Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-20.
Scope as published by A2LA
15 lines
ISO/IEC 17025
Active6727.01
The scope document we hold says it is valid until 2028-07-31.
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in China
- DEKRA Testing and Certification (Shanghai)ShanghaiA2LAShares 3 accredited test methodsANSI C63.4:2014EN 61000-4-2IEC 62477-1
- Shenzhen Toby Technology Co.,Shenzhen, GuangdongA2LAShares 3 accredited test methodsANSI C63.4:2014ANSI/TIA-603-EAS/NZS CISPR 11
- UL LLC/UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake BranchDongguanA2LAShares 3 accredited test methodsANSI C63.4:2014ANSI/TIA-603-EEN 18031-1
- CTC Laboratories, Inc.Shenzhen, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- Dongguan Nore Testing Center Co.,Dongguan, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.