UL LLC/UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch
Room 101, Building 2, No. 4, Information Road, Songshan Lake, Dongguan, 523808, People's Republic of China, Dongguan, China
- Accredited standards
- 52
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 52 standard numbers and the 15 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI24
ETSI EN 300 086
ETSI EN 300 113
ETSI EN 300 219-1
ETSI EN 300 296
ETSI EN 300 394-1
ETSI EN 301 166
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 526
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-4
ETSI EN 301 908-6
Show all 24
ETSI EN 301 908-25
ETSI EN 302 561
ETSI EN 303 340
ETSI EN 303 345-1
ETSI EN 303 372-2
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI TS 103 701
ETSI TS 134 121-1
ETSI TS 136 521-1
ETSI TS 138 521-1
ETSI TS 138 521-3
ETSI TS 151 010-1
EN7
EN 50360
EN 50364
EN 50383
EN 50385
EN 50566
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
IEC6
IEC 62209-1
IEC 62209-2
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 62680-1-2
IEC 62680-1-3
CISPR4
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 11national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national
National versions in the same scope
AS/NZS CISPR 14-1national version with changes
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national
National versions in the same scope
AS/NZS CISPR 15national version with changes
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+2 national
National versions in the same scope
AS/NZS CISPR 32identical to it
VCCI-CISPR 32probably the same standard; matched by number only
EN 18031 series3
EN 18031-1
EN 18031-2
EN 18031-3
IEC 61000 series3
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
AS/NZS 61000.3.2identical to it
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
AS/NZS 61000.3.3identical to it
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection+1 national
National versions in the same scope
AS/NZS 61000.3.11probably the same standard; matched by number only
Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI/TIA-603-E
FCC PART 15Radio Frequency Devices
ICES-001Industrial, Scientific and Medical (ISM) Equipment
RSS-GEN
ANSI/TIA-603-E; RSS-119; CFR 47, FCC Parts 22, 90, 95, 97, and 101; ANSI C63.26:2015; ETSI EN 300 086; ETSI EN 300 113; ETSI EN 300 219; ETSI EN 300 296; ETSI EN 301 166; ETSI EN 300 394-1; ETSI EN 302 561; AS/NZS 4295; IEC 62680-1-2; EN IEC 62680-1-2; SASO IEC 62680-1-2; USB Power Delivery Specification Revision 3.1; USB Power Delivery Specification Revision 3.2; USB Power Delivery Compliance Test Specification; IEC 62680-1-3; EN IEC 62680-1-3; SASO IEC 62680-1-3; IEC 62209-1; EN 62209-1; IEC 62209-2; EN 62209-2; EN 50566; BS EN 50566; RSS-102; RSS-102.SAR.MEAS; RSS-102.IPD.MEAS; IEEE C95.3-2021; IEC/IEEE 63195-1; EN 50360; BS EN 50360; EN 50383; IEEE Std. 1528; IEC/IEEE 62209-1528; EN IEC/IEEE 62209-1528; BS IEC/IEEE 62209-1528; AS NZS IEC IEEE 62209.1528 2021; Radiocommunications Equipment (General) Rules; Radiocommunications (Electromagnetic Radiation – Human Exposure) Standard; Standard for Limiting Exposure to Radiofrequency Fields – 100 kHz to 300 GHz Radiation Protection Series S-1; NZS 2772.1; AS/NZS 2772.2; Resolution No.700; Act No. 1630, New SAR Testing Procedure; EN 50364; BS EN 50364; EN 62479; IEC 62479; BS EN 62479; EN 50385; BS EN 50385; EN 50663; BS EN 50663; EN 50665; BS EN 50665; EN 62311; IEC 62311; BS EN IEC 62311; KDB 616217 D04; KDB 643646 D01; KDB 865664 D01; KDB 865664 D02; KDB 941225 D01; KDB 941225 D05; KDB 941225 D05A; KDB 941225 D06; KDB 941225 D07
Act No.1306; Act No.14448; ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+Errata to C63.10a-2024; ANSI C63.10-2020+Cor.1-2023; ANSI C63.10; ANSI C63.30:2021; CFR 47, FCC Parts 22, 24, 25, 27, 73, 74, and 96 (using ANSI/TIA-603-E and ANSI C63.26:2015); RSS-GEN; RSS-130; RSS-132; RSS-133; RSS-134; RSS-139; RSS-140; RSS-192; RSS-195; RSS-197; RSS-198; RSS-199; ANSI C63.26:2015; ANSI C63.27:2021; ETSI EN 303 340; ETSI EN 303 345-1; ETSI EN 303 372-2; ETSI EN 303 413; ETSI EN 301 511; ETSI TS 151 010-1; 3GPP TS 51.010-1; Act No.3 151; Act No. 3152; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI TS 134 121-1; 3GPP TS 34 121-1; Article 2 Paragraph 1 of Item 11-3 & 11-7; ETSI EN 301 908-4; ETSI EN 301 526; ETSI EN 301 908-6; 3GPP TS 34 122; ETSI 301 908-13; ETSI TS 136 521-1; 3GPP TS 36 521-1; Article 2 Paragraph 1 of Item 11-19; Article 2 Paragraph 1 of Item 11-21; Article 2 Paragraph 1 of Item 54; ETSI EN 301 908-25; ETSI TS 138 521-1; ETSI TS 138 521-3; 3GPP TS 38.521-1; 3GPP TS 38.521-3; MIC Notice No. 88 Appendix Nos. 29, 30, 33, 79, and 86; Radio Law Article 38-2-2, Paragraph 1, Items 11-30; Land Mobile Station for TD-5G-NR; Article 2 Paragraph 1 of Item 11-30; Article 2 Paragraph 1 of Item 11-34
EN 18031-1; BS EN 18031-1; EN 18031-2; BS EN 18031-2; EN 18031-3; BS EN 18031-3; ETSI TS 103 701
ISO/IEC 17025:2017; CFR 47, FCC Part 15, Subpart B (using ANSI C63.4:2014); CFR 47, FCC Part 18 (using MP-5:1986); ICES-GEN; ICES-001; ICES-003; ICES-005; EN 55011; CISPR 11; AS/NZS CISPR 11; J55011; BS EN 55011; SANS 211; CISPR 13:2009+AMD1:2015; EN 55014-1; CISPR 14-1; AS/NZS CISPR 14-1; J55014-1; BS EN 55014-1; EN IEC 55014-1; BS EN IEC 55014-1; SANS 214-1; DENAN Law Appendix 10 (EMC only); EN 55015; EN IEC 55015; BS EN IEC 55015; CISPR 15; AS/NZS CISPR 15; J55015; BS EN IEC 55015; SANS 215; CISPR 22:2008; EN 55032; CISPR 32; AS/NZS CISPR 32; J55032; VCCI-32-1; VCCI-CISPR 32; BS EN 55032; SANS 2332; VCCI-V-3 (up to 6 GHz); Act No.1120; IEC 61000-3-2; EN 61000-3-2; AS/NZS 61000.3.2; JIS C 61000-3-2; BS EN IEC 61000-3-2; EN IEC 61000-3-2; SANS 61000-3-2; IEC 61000-3-3; EN 61000-3-3; AS/NZS 61000.3.3; BS EN 61000-3-3; SANS 61000-3-3; IEC 61000-3-11; EN 61000-3-11; AS/NZS 61000.3.11; BS EN IEC 61000-3-11; EN IEC 61000-3-11; SANS 61000-3-11
ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020; FCC KDB 905462 D02 (v02); IEEE Std 1528:2013; ANSI/TIA-603-E; ANSI C63.26:2015
Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-20.
Scope as published by A2LA
8 lines
ISO/IEC 17025
Active4102.01
The scope document we hold says it is valid until 2028-03-31.
Accredited scope, certificate 4102.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; CFR 47, FCC Part 15, Subpart B (using ANSI C63.4:2014); CFR 47, FCC Part 18 (using MP-5:1986); ICES-GEN; ICES-001; ICES-003; ICES-005; EN 55011; CISPR 11; AS/NZS CISPR 11; J55011; BS EN 55011; SANS 211; CISPR 13:2009+AMD1:2015; EN 55014-1; CISPR 14-1; AS/NZS CISPR 14-1; J55014-1; BS EN 55014-1; EN IEC 55014-1; BS EN IEC 55014-1; SANS 214-1; DENAN Law Appendix 10 (EMC only); EN 55015; EN IEC 55015; BS EN IEC 55015; CISPR 15; AS/NZS CISPR 15; J55015; BS EN IEC 55015; SANS 215; CISPR 22:2008; EN 55032; CISPR 32; AS/NZS CISPR 32; J55032; VCCI-32-1; VCCI-CISPR 32; BS EN 55032; SANS 2332; VCCI-V-3 (up to 6 GHz); Act No.1120; IEC 61000-3-2; EN 61000-3-2; AS/NZS 61000.3.2; JIS C 61000-3-2; BS EN IEC 61000-3-2; EN IEC 61000-3-2; SANS 61000-3-2; IEC 61000-3-3; EN 61000-3-3; AS/NZS 61000.3.3; BS EN 61000-3-3; SANS 61000-3-3; IEC 61000-3-11; EN 61000-3-11; AS/NZS 61000.3.11; BS EN IEC 61000-3-11; EN IEC 61000-3-11; SANS 61000-3-11 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4102.01) Revised 02/04/2026 Page 2 of 7
Test Technology:
Test Method(s) 1, 2:
Generic Emissions Standards
IEC 61000-6-3; EN 61000-6-3; AS/NZS 61000.6.3;
BS EN 61000-6-3; EN IEC 61000-6-3;
BS EN IEC 61000-6-3; SANS 61000-6-3;
IEC 61000-6-4; EN 61000-6-4; AS/NZS 61000.6.4;
BS EN IEC 61000-6-4; EN IEC 61000-6-4;
SANS 61000-6-4
Radio ETSI EN 301 489-1; ETSI EN 301 489-3;
ETSI EN 301 489-5; ETSI EN 301 489-7;
ETSI EN 301 489-9; ETSI EN 301 489-17;
ETSI EN 301 489-19; ETSI EN 301 489-25;
ETSI EN 301 489-33; ETSI EN 301 489-34;
ETSI EN 301 489-52; ETSI EN 301 489-53
Immunity
Electrostatic Discharge (ESD)
IEC 61000-4-2; EN 61000-4-2; EN IEC 61000-4-2;
BS EN IEC 61000-4-2; BS EN 61000-4-2; SANS 61000-4-2
Radiated Immunity
IEC 61000-4-3; EN 61000-4-3; BS EN IEC 61000-4-3;
EN IEC 61000-4-3; SANS 61000-4-3
Electrical Fast Transient / Burst IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4;
SANS 61000-4-4
Surge Immunity IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5;
SANS 61000-4-5
Conducted Immunity
IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6;
EN IEC 61000-4-6; BS EN IEC 61000-4-6; SANS 61000-4-6
Power Frequency Magnetic Field
IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8;
SANS 61000-4-8
Voltage Dip & Interrupt
IEC 61000-4-11; EN 61000-4-11; BS EN IEC 61000-4-11;
EN IEC 61000-4-11; SANS 61000-4-11
Ring Wave IEC 61000-4-12; EN 61000-4-12; BS EN 61000-4-12;
SANS 61000-4-12
Interharmonics IEC 61000-4-13; EN 61000-4-13; BS EN 61000-4-13;
SANS 61000-4-13
Radiated Fields in Close
Proximity Immunity Test
IEC 61000-4-39; EN 61000-4-39; BS EN 61000-4-39
Generic or Product Specific
Immunity Standards
IEC 61000-6-1; EN 61000-6-1; AS/NZS 61000.6.1;
BS EN IEC 61000-6-1; EN IEC 61000-6-1;
SANS 61000-6-1; IEC 61000-6-2; EN 61000-6-2; | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4102.01) Revised 02/04/2026 Page 3 of 7
Test Technology:
Test Method(s) 1, 2:
Generic or Product Specific
Immunity Standards
(cont.)
AS/NZS 61000.6.2; BS EN IEC 61000-6-2;
EN IEC 61000-6-2; SANS 61000-6-2;
EN 55014-2; CISPR 14-2; AS/NZS CISPR 14-2;
EN IEC 55014-1; BS EN IEC 55014-1; IEC 55014-1
BS EN 55014-2; SANS 214-2;
CISPR 20:2006/AMD1:2013; CISPR 24:2010+AMD1:2015;
EN 55035; CISPR 35; SANS 2335; BS EN 55035;
EN 50130-4; IEC 61547; EN 61547; BS EN 61547;
EN IEC 61547; BS EN IEC 61547;
SANS 61547; Act No.1120;
IEC 61326-1; EN 61326-1; EN IEC 61326-1;
BS EN IEC 61326-1; BS EN 61326;
IEC 61326-2-6; EN 61326-2-6; EN IEC 61326-2-6;
BS EN IEC 61326-2-6; BS EN 61326-2-6;
IEC 60601-1-2 (2014); IEC 60601-1-2; EN 60601-1-2;
BS EN 60601-1-2; SANS 60601-1-2;
IEC TS 60601-4-2; SANS 61326-1; EN 300 386
Radio Frequency Testing
FHSS/DSSS Devices
2.4 GHz
ETSI EN 300 328;
MIC Notice No. 88 Appendix No. 43 & 44
RLAN Devices
5/6 GHz
ETSI EN 301 893; ETSI EN 302 502; ETSI EN 303 687;
MIC Notice No. 88 Appendix No. 45 & 47;
47 CFR, Part 15, Subpart E (using ANSI C63.10:2020 or
FCC KDB 905462 D02 (v02), April 08, 2016)
Short Range Devices (SRD)
ETSI EN 300 220-1; ETSI EN 300 220-2;
ETSI EN 300 220-3-2; EN 300 422-1;
EN 300 422-2; EN 300 422-3;
ETSI EN 300 330; ETSI EN 300 440;
ETSI EN 302 291-1; ETSI EN 302 291-2;
ETSI EN 303 417; ETSI EN 302 065-1;
ETSI EN 302 065-2; ETSI EN 302 065-3;
Radio Law Article 38-2-2, Paragraph 1, Items 8,
and 47-1/2/3
Radio Frequency Identification
Devices (RFID)
(865 to 868) MHz
ETSI EN 302 208-1; ETSI EN 302 208-2
Intentional Radiators
CFR 47, FCC Part 15, Subpart C and Subpart F
(using ANSI C63.10:2020);
RSS-GEN; RSS-210 (≤ 100 GHz); RSS-211 (≤ 100 GHz);
RSS-216 (≤ 100 GHz); RSS-220 (≤ 100 GHz);
RSS-247; RSS-248; RSS-310;
AS/NZS 4268; Act No.423; Resolution No.680; | ||
| 4 | Act No.1306; Act No.14448; ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024+Errata to C63.10a-2024; ANSI C63.10-2020+Cor.1-2023; ANSI C63.10; ANSI C63.30:2021; CFR 47, FCC Parts 22, 24, 25, 27, 73, 74, and 96 (using ANSI/TIA-603-E and ANSI C63.26:2015); RSS-GEN; RSS-130; RSS-132; RSS-133; RSS-134; RSS-139; RSS-140; RSS-192; RSS-195; RSS-197; RSS-198; RSS-199; ANSI C63.26:2015; ANSI C63.27:2021; ETSI EN 303 340; ETSI EN 303 345-1; ETSI EN 303 372-2; ETSI EN 303 413; ETSI EN 301 511; ETSI TS 151 010-1; 3GPP TS 51.010-1; Act No.3 151; Act No. 3152; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI TS 134 121-1; 3GPP TS 34 121-1; Article 2 Paragraph 1 of Item 11-3 & 11-7; ETSI EN 301 908-4; ETSI EN 301 526; ETSI EN 301 908-6; 3GPP TS 34 122; ETSI 301 908-13; ETSI TS 136 521-1; 3GPP TS 36 521-1; Article 2 Paragraph 1 of Item 11-19; Article 2 Paragraph 1 of Item 11-21; Article 2 Paragraph 1 of Item 54; ETSI EN 301 908-25; ETSI TS 138 521-1; ETSI TS 138 521-3; 3GPP TS 38.521-1; 3GPP TS 38.521-3; MIC Notice No. 88 Appendix Nos. 29, 30, 33, 79, and 86; Radio Law Article 38-2-2, Paragraph 1, Items 11-30; Land Mobile Station for TD-5G-NR; Article 2 Paragraph 1 of Item 11-30; Article 2 Paragraph 1 of Item 11-34 | Licensed Transmitter / Receiver Emissions; GSM; WCDMA; CDMA; TD-SCDMA; LTE; NR | - |
| 5 | ANSI/TIA-603-E; RSS-119; CFR 47, FCC Parts 22, 90, 95, 97, and 101; ANSI C63.26:2015; ETSI EN 300 086; ETSI EN 300 113; ETSI EN 300 219; ETSI EN 300 296; ETSI EN 301 166; ETSI EN 300 394-1; ETSI EN 302 561; AS/NZS 4295; IEC 62680-1-2; EN IEC 62680-1-2; SASO IEC 62680-1-2; USB Power Delivery Specification Revision 3.1; USB Power Delivery Specification Revision 3.2; USB Power Delivery Compliance Test Specification; IEC 62680-1-3; EN IEC 62680-1-3; SASO IEC 62680-1-3; IEC 62209-1; EN 62209-1; IEC 62209-2; EN 62209-2; EN 50566; BS EN 50566; RSS-102; RSS-102.SAR.MEAS; RSS-102.IPD.MEAS; IEEE C95.3-2021; IEC/IEEE 63195-1; EN 50360; BS EN 50360; EN 50383; IEEE Std. 1528; IEC/IEEE 62209-1528; EN IEC/IEEE 62209-1528; BS IEC/IEEE 62209-1528; AS NZS IEC IEEE 62209.1528 2021; Radiocommunications Equipment (General) Rules; Radiocommunications (Electromagnetic Radiation – Human Exposure) Standard; Standard for Limiting Exposure to Radiofrequency Fields – 100 kHz to 300 GHz Radiation Protection Series S-1; NZS 2772.1; AS/NZS 2772.2; Resolution No.700; Act No. 1630, New SAR Testing Procedure; EN 50364; BS EN 50364; EN 62479; IEC 62479; BS EN 62479; EN 50385; BS EN 50385; EN 50663; BS EN 50663; EN 50665; BS EN 50665; EN 62311; IEC 62311; BS EN IEC 62311; KDB 616217 D04; KDB 643646 D01; KDB 865664 D01; KDB 865664 D02; KDB 941225 D01; KDB 941225 D05; KDB 941225 D05A; KDB 941225 D06; KDB 941225 D07 | Land Mobile Devices, Wireless Devices, Hand-Held/Body-Mounted Devices | See scope document |
| 6 | EN 18031-1; BS EN 18031-1; EN 18031-2; BS EN 18031-2; EN 18031-3; BS EN 18031-3; ETSI TS 103 701 | - | - |
| 7 | ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020; FCC KDB 905462 D02 (v02); IEEE Std 1528:2013; ANSI/TIA-603-E; ANSI C63.26:2015 | - | to 110000 MHz |
| 8 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- Intertek Testing Services (Shanghai FTZ) Co.,ShanghaiA2LAShares 4 accredited test methodsANSI C63.4:2014ANSI/TIA-603-EICES-001
- DEKRA Testing and Certification (Suzhou) Co.,Suzhou, Jiangsu ProvinceA2LAShares 3 accredited test methodsANSI C63.4:2014ICES-001RSS-GEN
- Dongguan Nore Testing Center Co.,Dongguan, GuangdongA2LAShares 3 accredited test methodsANSI C63.4:2014ANSI/TIA-603-EICES-001
- Guangdong KEYS Testing Technology Co.,Dongguan, GuangdongA2LAShares 3 accredited test methodsANSI C63.4:2014ICES-001RSS-GEN
- Intertek Testing Services Shenzhen Ltd., Longhua BranchShenzhenA2LAShares 3 accredited test methodsANSI C63.4:2014ANSI/TIA-603-EICES-001
Accreditation data refreshed from the A2LA register on .