Intertek Testing Services Shenzhen Ltd., Longhua Branch
101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, Shenzhen, People's Republic of China, Shenzhen, China
Visit website- Accredited standards
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 4 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI/TIA-603-E
FCC PART 15Radio Frequency Devices
ICES-001Industrial, Scientific and Medical (ISM) Equipment
ANSI/CAN/UL/ULC 2271; ANSI/CAN/UL/ULC 2271:2018 Ed.2; ANSI/CAN/UL 2272; ANSI/CAN/UL 2272:2016 Ed.1+R:25Feb2019; ANSI/CAN/UL 2849; ANSI/CAN/UL 2849:2020 Ed.1+R:17Jun2022; ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015
ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015; IEEE Std 1528:2013
47 CFR, FCC Part 15, Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); ICES-001; ICES-003; ICES-005; BETS-7; IEEE Std 1528:2013; IEC/IEEE 62209-1528; ANSI/IEEE C95.1; RSS-102; RSS-102.SAR.MEAS; RSS-102.NS.MEAS; SPR-002; KDB 865664 D01 v01r04; KDB 447498 D01 v06; 47 CFR, FCC Parts 22, 24, 25, 27, 90, 95, 96, 97, and 101 (using ANSI/TIA-603-E, ANSI/TIA-102.CAAA-E, and ANSI C63.26:2015); RSS-130; RSS-132; RSS-133; RSS-139; RSS-192; RSS-195; RSS-197; RSS-199; 3GPP TS 38.521-1; 3GPP TS 38.521-3; 47 CFR, FCC Part 15, Subpart C (using ANSI C63.10:2013); 47 CFR, FCC Part 15, Subpart E (using ANSI C63.10:2013 and FCC KDB 905462 D02 (v02)); RSS-GEN; RSS-210 (< 40 GHz); RSS-216 (< 40 GHz); RSS-247 (with or without DFS); RSS-310; ANSI C63.10:2013
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active4242.01
The scope document we hold says it is valid until 2027-08-31.
Accredited scope, certificate 4242.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | 47 CFR, FCC Part 15, Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); ICES-001; ICES-003; ICES-005; BETS-7; IEEE Std 1528:2013; IEC/IEEE 62209-1528; ANSI/IEEE C95.1; RSS-102; RSS-102.SAR.MEAS; RSS-102.NS.MEAS; SPR-002; KDB 865664 D01 v01r04; KDB 447498 D01 v06; 47 CFR, FCC Parts 22, 24, 25, 27, 90, 95, 96, 97, and 101 (using ANSI/TIA-603-E, ANSI/TIA-102.CAAA-E, and ANSI C63.26:2015); RSS-130; RSS-132; RSS-133; RSS-139; RSS-192; RSS-195; RSS-197; RSS-199; 3GPP TS 38.521-1; 3GPP TS 38.521-3; 47 CFR, FCC Part 15, Subpart C (using ANSI C63.10:2013); 47 CFR, FCC Part 15, Subpart E (using ANSI C63.10:2013 and FCC KDB 905462 D02 (v02)); RSS-GEN; RSS-210 (< 40 GHz); RSS-216 (< 40 GHz); RSS-247 (with or without DFS); RSS-310; ANSI C63.10:2013 | - | to 40 GHz |
| 2 | ANSI/CAN/UL/ULC 2271; ANSI/CAN/UL/ULC 2271:2018 Ed.2; ANSI/CAN/UL 2272; ANSI/CAN/UL 2272:2016 Ed.1+R:25Feb2019; ANSI/CAN/UL 2849; ANSI/CAN/UL 2849:2020 Ed.1+R:17Jun2022; ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015 | - | to 40000 MHz |
| 3 | ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015; IEEE Std 1528:2013 | - | to 40000 MHz |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
INTERTEK TESTING SERVICES SHENZHEN LTD.
LONGHUA BRANCH
Shenzhen, People’s Republic of China
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 9th day of September 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 4242.01
Valid to August 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- Dongguan Nore Testing Center Co.,Dongguan, GuangdongA2LAShares 3 accredited test methodsANSI C63.4:2014ANSI/TIA-603-EICES-001
- Intertek Testing Services (Shanghai FTZ) Co.,ShanghaiA2LAShares 3 accredited test methodsANSI C63.4:2014ANSI/TIA-603-EICES-001
- MRT Technology (Suzhou) Co.,Suzhou, JiangsuA2LAShares 3 accredited test methodsANSI C63.4:2014ANSI/TIA-603-EICES-001
- UL LLC/UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake BranchDongguanA2LAShares 3 accredited test methodsANSI C63.4:2014ANSI/TIA-603-EICES-001
- CTC Laboratories, Inc.Shenzhen, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.