Greer Steel Company Metallurgical
1 Boat Street, 44622, Dover, OH, United States
Visit website- Accredited standards
- 12
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 12 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM11
ASTM A892
ASTM E3Standard Guide for Preparation of Metallographic Specimens
ASTM E8Standard Test Methods for Tension Testing of Metallic Materials
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM E45Standard Test Methods for Determining the Inclusion Content of Steel
ASTM E112Standard Test Methods for Determining Average Grain Size
ASTM E290Standard Test Methods for Bend Testing of Material for Ductility
ASTM E415Standard Test Method for Analysis of Carbon and Low-Alloy Steel by Spark Atomic Emission Spectrometry
ASTM E517
ASTM E646
ASTM E1077
Other standards1
ISO 6892-1Metallic materials - Tensile testing - Part 1: Method of test at room temperature
ASTM E290; ASTM E18; ASTM E8/8M; ASTM E517; ASTM E646; JIS Z 2201; ISO 6892-1; SAE J911; ASTM E3; ASTM E112; ASTM E45; ASTM E1077; SAE J419; ASTM A892; Greer Lab Procedure WI-010
ASTM E415
Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-20.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active1421.01
The scope document we hold says it is valid until 2028-05-31.
Accredited scope, certificate 1421.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM E290; ASTM E18; ASTM E8/8M; ASTM E517; ASTM E646; JIS Z 2201; ISO 6892-1; SAE J911; ASTM E3; ASTM E112; ASTM E45; ASTM E1077; SAE J419; ASTM A892; Greer Lab Procedure WI-010 | plain carbon, alloy, and stainless steels | to 60 klbs |
| 2 | ASTM E415 | Al, B, C, Ca, Cb, Cr, Cu, Mn, Mo, Ni, P, S, Si, Ti, V | - |
| 3 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- SGS North AmericaMelrose Park, IL · ~557 kmA2LAShares 2 accredited test methodsASTM E290ASTM E415
- Element Materials Technology New BerlinNew Berlin, WI · ~615 kmA2LAShares 2 accredited test methodsASTM E290ASTM E415
- Goolsby TestingHumble, TX · ~1,710 kmA2LAShares 2 accredited test methodsASTM E290ASTM E415
- Tensile Testing MetallurgicalCleveland, OH · ~111 kmA2LAShares 1 accredited test methodASTM E415
- KTA - TATORPittsburgh, PA · ~124 kmA2LAShares 1 accredited test methodASTM E290
Accreditation data refreshed from the A2LA register on .