What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 16 scope lines.
A2LA certificate 2418.01 · 16 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2418.01) 08/20/2024 Page 2 of 15
Parameter/Equipment
Range
CMC2,5 (±)
Comments
Resistance – Generate
& Measure, Fixed
Points
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
1 GΩ
0.46 µΩ/Ω
0.18 µΩ/Ω
0.19 µΩ/Ω
0.38 µΩ/Ω
0.16 µΩ/Ω
0.57 µΩ/Ω
0.77 µΩ/Ω
4.0 µΩ/Ω
21 µΩ/Ω
13 µΩ/Ω
Reference resistors held
under SPC measured
with MI 6242D direct
current comparator
bridge.
Resistance – Generate,
Fixed Points
1.9 Ω
19 Ω
190 Ω
1.9 kΩ
19 kΩ
190 kΩ
1.9 MΩ
19 MΩ
27 µΩ/Ω
4.9 µΩ/Ω
2.2 µΩ/Ω
2.2 µΩ/Ω
2.2 µΩ/Ω
2.2 µΩ/Ω
4.0 µΩ/Ω
21 µΩ/Ω
Fluke 5730A & long
scale DMM
Resistance – Measure,
Fixed Points
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
6.9 µΩ/Ω
6.0 µΩ/Ω
2.8 µΩ/Ω
3.0 µΩ/Ω
0.66 µΩ/Ω
0.54 µΩ/Ω
0.82 µΩ/Ω
0.79 µΩ/Ω
0.56 µΩ/Ω
0.69 µΩ/Ω
0.78 µΩ/Ω
0.68 µΩ/Ω
2.1 µΩ/Ω
1.4 µΩ/Ω
4.4 µΩ/Ω
4.1 µΩ/Ω
13 µΩ/Ω
Fluke 5730A calibration
ratiometric transfer
techniques performed
utilizing reference
resistors held under SPC,
& 8508A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2418.01) 08/20/2024 Page 3 of 15
Parameter/Equipment
Range CMC
2,5 (±)
Comments
Resistance – Generate,
Fixed Point
1 Ω
0.08 µΩ/Ω
Reference resistor held
under SPC
DC Current – Measure
± 200 µA
± 2 mA
± 20 mA
± 200 mA
± 2 A
± 3 A
± 5 A
± 10 A
6.3 µA/A
6.1 µA/A
6.1 µA/A
6.1 µA/A
32 µA/A
45 µA/A
36 µA/A
36 µA/A
Fluke 5730A calibration
direct transfer techniques
performed utilizing
reference resistors held
under SPC, A40B, &
8508A
DC Voltage – Generate
& Measure
(0 to 0.22) V
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
1.6 µV/V + 0.52 µV
1.6 µV/V + 1.1 µV
0.80 µV/V + 6.0 µV
0.80 µV/V + 6.6 µV
1.6 µV/V + 68 µV
2.0 µV/V + 1.1 mV
Fluke 5730A & long
scale DMM
DC Current – Generate
(0 to 0.22) mA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
20 µA/A + 2.1 nA
20 µA/A + 13 nA
20 µA/A + 0.13 µA
22 µA/A + 1.3 µA
32 µA/A + 64 µA
100 µA/A + 0.46 mA
Fluke 5730A & long
scale DMM | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2418.01) 08/20/2024 Page 4 of 15
Parameter/Range
Frequency
CMC2.4.5 (±)
Comments
AC Current – Measure &
Generate, Fixed Points
(100 to 200) µA
(1 to 2) mA
(10 to 20) mA
(100 to 200) mA
(1 to 2) A
(10 to 20) A
10 Hz
20 Hz
40 Hz
1 kHz
5 kHz
10 kHz
10 Hz
20 Hz
40 Hz
1 kHz
5 kHz
10 kHz
10 Hz
20 Hz
40 Hz
1 kHz
5 kHz
10 kHz
10 Hz
20 Hz
40 Hz
1 kHz
5 kHz
10 kHz
40 Hz
1 kHz
5 kHz
10 kHz
40 Hz
1 kHz
5 kHz
10 kHz
0.19 %
100 µA/A
75 µA/A
74 µA/A
78 µA/A
90 µA/A
0.18 %
82 µA/A
50 µA/A
47 µA/A
47 µA/A
47 µA/A
0.16 %
60 µA/A
44 µA/A
32 µA/A
32 µA/A
32 µA/A
0.16 %
58 µA/A
31 µA/A
30 µA/A
30 µA/A
30 µA/A
47 µA/A
44 µA/A
45 µA/A
50 µA/A
76 µA/A
72 µA/A
77 µA/A
93 µA/A
Fluke 5730A
calibration direct
transfer techniques
performed utilizing
Fluke A40B, 5790B | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2418.01) 08/20/2024 Page 5 of 15
Parameter/Range
Frequency CMC
2,4,5 (±)
Comments
AC Voltage – Measure &
Generate, Fixed Points
1 mV
2 mV
3 mV
10 mV
20 mV
30 mV
100 mV
1 kHz
10 Hz
20 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
1 MHz
1 kHz
1 kHz
10 Hz
20 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
1 MHz
1 kHz
1 kHz
0.87 %
1.9 %
1.1 %
0.86 %
0.86 %
0.86 %
1.5 %
2.0 %
3.4 %
5.0 %
6.0 %
0.35 %
0.15 %
0.29 %
0.21 %
0.15 %
0.15 %
0.15 %
0.25 %
0.35 %
0.81 %
1.1 %
1.7 %
79 µV/V
39 µV/V
Direct measurement
techniques of the Fluke
5730 using a Fluke
5790B | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2418.01) 08/20/2024 Page 6 of 15
Parameter/Range
Frequency
CMC
2, 4, 5
(±)
Comments
AC Voltage – Measure &
Generate, Fixed Points
(cont)
200 mV
300 mV
1 V
2 V
2.1 V
20 V
10 Hz
20 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
1 MHz
1 kHz
1 kHz
10 Hz
20 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
1 MHz
1 kHz
10 Hz
20 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
300 kHz
500 kHz
1 MHz
0.18 %
80 µV/V
43 µV/V
38 µV/V
39 µV/V
66 µV/V
0.15 %
0.23 %
0.36 %
0.85 %
30 µV/V
23 µV/V
0.17 %
57 µV/V
26 µV/V
21 µV/V
20 µV/V
37 µV/V
58 µV/V
0.13 %
0.21 %
0.75 %
21 µV/V
0.17 %
63 µV/V
27 µV/V
23 µV/V
23 µV/V
39 µV/V
65 µV/V
0.16 %
0.32 %
0.97 %
Direct measurement
techniques of the Fluke
5730 using a Fluke
5790B | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2418.01) 08/20/2024 Page 7 of 15
Parameter/Range
Frequency CMC
2, 4, 5
(±)
Comments
AC Voltage – Measure &
Generate, Fixed Points
(cont)
200 V
300 V
600 V
1000 V
10 Hz
20 Hz
40 Hz
1 kHz
20 kHz
50 kHz
100 kHz
20 kHz
50 kHz
100 kHz
40 Hz
50 Hz
300 Hz
1 kHz
20 kHz
30 kHz
0.17 %
59 µV/V
29 µV/V
26 µV/V
26 µV/V
56 µV/V
79 µV/V
37 µV/V
0.11 %
0.40 %
36 µV/V
39 µV/V
34 µV/V
34 µV/V
34 µV/V
0.11 %
Direct measurement
techniques of the
Fluke 5730 using a
Fluke 5790B | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2418.01) 08/20/2024 Page 8 of 15
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Voltage Flatness –
Measure, Fixed Points
Ref 1 kHz
1 mV
2 mV
20 mV
30 mV
30 Hz
100 Hz
10 kHz
100 kHz
500 kHz
1 MHz
10 MHz
20 MHz
30 MHz
30 Hz
100 Hz
10 kHz
100 kHz
500 kHz
1 MHz
10 MHz
20 MHz
30 MHz
30 Hz
100 Hz
10 kHz
100 kHz
500 kHz
1 MHz
10 MHz
20 MHz
30 MHz
30 Hz
100 Hz
10 kHz
100 kHz
500 kHz
1 MHz
10 MHz
20 MHz
30 MHz
0.46 %
0.46 %
0.46 %
0.47 %
1.4 %
1.4 %
2.2 %
3.2 %
7.2 %
0.45 %
0.42 %
0.42 %
0.42 %
0.95 %
0.96 %
1.3 %
1.9 %
3.6 %
0.41 %
0.41 %
0.40 %
0.40 %
0.56 %
0.57 %
0.84 %
1.5 %
3.2 %
0.41 %
0.41 %
0.41 %
0.41 %
0.41 %
0.42 %
0.84 %
1.4 %
3.1 %
Direct measurement
techniques of the
Fluke 5730 using a
Fluke 5790B | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2418.01) 08/20/2024 Page 9 of 15
Parameter/Range
Frequency CMC
2, 4, 5 (±)
Comments
AC Voltage Flatness –
Measure, Fixed Points
Ref 1 kHz (cont)
100 mV
300 mV
1 V
3 V
30 Hz
100 Hz
10 kHz
100 kHz
500 kHz
1 MHz
10 MHz
20 MHz
30 MHz
30 Hz
100 Hz
10 kHz
100 kHz
500 kHz
1 MHz
10 MHz
20 MHz
30 MHz
30 Hz
100 Hz
10 kHz
100 kHz
500 kHz
1 MHz
10 MHz
20 MHz
30 MHz
30 Hz
100 Hz
10 kHz
100 kHz
500 kHz
1 MHz
10 MHz
20 MHz
30 MHz
0.33 %
0.33 %
0.33 %
0.33 %
0.33 %
0.41 %
0.84 %
1.4 %
3.1 %
0.25 %
0.25 %
0.25 %
0.25 %
0.25 %
0.41 %
0.84 %
1.3 %
3.1 %
0.25 %
0.25 %
0.25 %
0.25 %
0.25 %
0.41 %
0.84 %
1.3 %
3.0 %
0.25 %
0.25 %
0.25 %
0.25 %
0.25 %
0.41 %
0.84 %
1.3 %
3.0 %
Direct measurement
techniques of the
Fluke 5730 using a
Fluke 5790B | ||
| 10 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2418.01) 08/20/2024 Page 10 of 15
II. Electrical – RF/Microwave
Parameter/Range
Frequency CMC
2,3,5
(±)
Comments
RF Power – Relative
Thermocouple & Diode
Sensors Requiring 50
MHz Reference
(-20 to +20) dBm
(0.1 to 1) MHz
(1.1 to 10) MHz
(10.1 to 100) MHz
(100.1 to 4000) MHz
(4000.1 to 9000) MHz
(9000.1 to 15 000) MHz
(15 000.1 to 18 000) MHz
(18 000.1 to 21 000) MHz
(21 000.1 to 24 000) MHz
(24 000.1 to 26 500) MHz
(26 500.1 to 29 000) MHz
(29 000.1 to 32 000) MHz
(32 000.1 to 35 000) MHz
(35 000.1 to 38 000) MHz
(38 000.1 to 41 000) MHz
(41 000.1 to 44 000) MHz
(44 000.1 to 47 000) MHz
(47 000.1 to 50 000) MHz
0.9 CF
0.71 CF
0.67 CF
0.75 CF
0.90 CF
1.0 CF
1.1 CF
1.6 CF
1.7 CF
1.8 CF
1.9 CF
2.0 CF
1.9 CF
1.8 CF
2.5 CF
2.6 CF
3.0 CF
2.7 CF
Network analyzer with
calibration kit | -20 to 20 dBm |
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2418.01) 08/20/2024 Page 11 of 15
Parameter/Range
Frequency CMC
2, 5, 6 (±)
Comments
Power Sensor VSWR
(Ratio)
100 kHz to 4.2 GHz
10 MHz to 18 GHz
50 MHz to 26.5 GHz
50 MHz to 50 GHz
100 kHz to 6 GHz
50 MHz to 50 GHz
0.018 VSWR
0.050 VSWR
0.024 VSWR
0.15 VSWR
0.018 VSWR
0.040 VSWR
Agilent 8753ES vector
analyzer with appropriate
calibration kit
> 10 MHz – HP 8757
series scalar network
analyzer with appropriate
directional bridge (HP
85027A, B, C, & D)
Agilent 8753ES vector
analyzer with appropriate
calibration kit
Agilent 8510C vector
analyzer with 8517B test
set, 83651A source, &
appropriate calibration kit
Attenuation – Measure
10 dB
20 dB
30 dB
40 dB
10 dB
20 dB
30 dB
40 dB
10 dB
20 dB
30 dB
40 dB
50 dB
60 dB
70 dB
80 dB
90 dB
100 dB
110 dB
100 kHz to 6 GHz
100 kHz to 6 GHz
100 kHz to 6 GHz
100 kHz to 6 GHz
50 MHz to 50 GHz
50 MHz to 50 GHz
50 MHz to 50 GHz
50 MHz to 50 GHz
3 MHz to 1.3 GHz
3 MHz to 1.3 GHz
3 MHz to 1.3 GHz
3 MHz to 1.3 GHz
3 MHz to 1.3 GHz
3 MHz to 1.3 GHz
3 MHz to 1.3 GHz
3 MHz to 1.3 GHz
3 MHz to 1.3 GHz
3 MHz to 1.3 GHz
3 MHz to 1.3 GHz
0.13 dB of rdg
0.13 dB of rdg
0.13 dB of rdg
0.13 dB of rdg
0.42 dB of rdg
0.42 dB of rdg
0.42 dB of rdg
0.42 dB of rdg
0.06 dB of rdg
0.08 dB of rdg
0.10 dB of rdg
0.13 dB of rdg
0.17 dB of rdg
0.22 dB of rdg
0.24 dB of rdg
0.26 dB of rdg
0.33 dB of rdg
0.35 dB of rdg
0.38 dB of rdg
Agilent 8753ES vector
analyzer with appropriate
calibration kit
Agilent 8510C vector
analyzer with 8517B test
set, 83651A source, &
appropriate calibration kit
Direct measure, HP
8902A measuring
receiver, all measurement
systems components time
based locked
N5225A PNA | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2418.01) 08/20/2024 Page 12 of 15
Parameter/Range
Frequency CMC
2, 5 (±)
Comments
Attenuation – Measure
(cont)
10 dB
20 dB
30 dB
40 dB
50 dB
60 dB
70 dB
80 dB
90 dB
10 MHz to 26.5 GHz
10 MHz to 26.5 GHz
10 MHz to 26.5 GHz
10 MHz to 26.5 GHz
10 MHz to 26.5 GHz
10 MHz to 26.5 GHz
10 MHz to 26.5 GHz
10 MHz to 26.5 GHz
10 MHz to 26.5 GHz
0.13 dB of rdg
0.14 dB of rdg
0.15 dB of rdg
0.17 dB of rdg
0.22 dB of rdg
0.24 dB of rdg
0.26 dB of rdg
0.28 dB of rdg
0.35 dB of rdg
Direct measure, HP
8902A measuring
receiver system with HP
11793A converter, &
appropriate local
oscillator, all
measurement systems
components time bases
locked
III. Mechanical
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
Vibration3 –
Accelerometers
(10 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
1.9 %
3.6 %
4.1 %
Vibration transducer
calibration system
Pressure – Generate
Up to 50 psi
(50 to 100) psi
(100 to 1000) psi
0.0033 psi
0.021 psi
0.29 psi
Fluke 6270A, 8370A &
Fluke PM600 pressure
modules | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2418.01) 08/20/2024 Page 13 of 15
IV. Thermodynamics
Parameter/Equipment
Range
CMC2,7 (±)
Comments
Temperature – Measure
(- 80 to -50) °C
(- 50 to 30) °C
(30 to 50) °C
(50 to 650) °C
0.034 °C
0.020 °C
0.020 °C
0.33 °C
Fluke 1595A, Hart
5628 & Fluke 7381
Liquid bath
Fluke 1595A, Hart
5628 & Fluke 9190 Dry
well
Fluke 1595A, Hart
5628 & Fluke 9144 Dry
well
Humidity – Measuring
Equipment
(10 to 90) % RH
0.55 % RH
Thunder Scientific 2500
V. Time & Frequency
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Frequency Dissemination
10 MHz
10-10 Hz/Hz
Fluke 910R GPS-
controlled rubidium
frequency standard &
Symmetricom Xli time &
frequency system | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2418.01) 08/20/2024 Page 14 of 15
SATELLITE
NORTHROP GRUMMAN MISSION SYSTEMS BWI CALIBRATION LAB
West Building Metrology Laboratory
7323 Aviation Boulevard,
Baltimore, MD 21203
Bob Dodds Phone: 410 689 6972
I. Dimensional
Parameter/Equipment
Range CMC2 (±)
Comments
Calipers – Digital,
Resolution = 0.0005
in
Up to 6 in
Up to 12 in
Up to 18 in
Up to 24 in
330 μin
330 μin
310 μin
380 μin
Gage blocks
Calipers – Dial,
Resolution = 0.001
in
Up to 6 in
Up to 12 in
Up to 18 in
Up to 24 in
460 µin
520 µin
460 µin
430 µin
Gage blocks
Outside Micrometers –
Resolution = 0.0001 in
Up to 1 in
(1 to 2) in
(2 to 3) in
(3 to 4) in
(4 to 5) in
(5 to 6) in
30 µin
59 µin
60 µin
61 µin
63 µin
65 µin
Gage blocks
Indicators – Dial &
Digital
Resolution = 0.00005
Up to 1 in
(1 to 2) in
(2 to 3) in
(3 to 4) in
130 µin
200 µin
130 µin
260 µin
Dial indicator calibrator,
Optimar 100
Plain Cylindrical Plug
Gages
(0.050 to 1.00) in
24 μin
Gage blocks with linear
length machine
________________
1 This laboratory is not normally available for commercial calibration service. | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2418.01) 08/20/2024 Page 15 of 15
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3
In the statement of CMC, CF stands for calibration factor.
4 In the statement of CMC, percentage are percentages of reading.
5 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
6
In the statement of CMC, VSWR refers to Voltage Standing Wave Ratio.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
8 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 16 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Northrop Grumman Corporation, 1745A West Nursery Road, Linthicum, MD, 21090, US
39.21058, -76.66257
Open in MapsLabs with overlapping accredited scope in United States
- American Scale & EquipmentBaltimore, MD · ~22 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Baltimore, MDSparks, MD · ~36 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Automated PrecisionRockville, MD · ~45 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - Washington D.C.Sterling, VA · ~68 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Morehouse Instrument CompanyYork, PA · ~84 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.