OKI ENGINEERING CO.,
4-1-1, Ojimaminami, Honjo-shi, Saitama-ken, 367-8686, Japan, Honjo-shi, Saitama-ken, Japan
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at OKI ENGINEERING CO.,?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 4727.01Active
Accredited standards
11Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC 61000 series
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC/EN 61000-4-2; ISO 10605; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-5(2005); ISO 7637-2; ISO 7637-2 (2004); ISO 16750-2
IEC/EN 61000-4-2; ISO 10605; ISO 10605 (2001); IEC/EN 61000-4-4
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC/EN 61000-4-2; ISO 10605; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-5(2005); ISO 7637-2; ISO 7637-2 (2004); ISO 16750-2
IEC/EN 61000-4-2; ISO 10605; ISO 10605 (2001); IEC/EN 61000-4-4
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC/EN 61000-4-2; ISO 10605; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-5(2005); ISO 7637-2; ISO 7637-2 (2004); ISO 16750-2
IEC/EN 61000-4-5; IEC/EN 61000-4-5 (2005); ISO 7637-2; ISO 7637-2 (2004); ISO 16750-2
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
CISPR 16-1-2; IEC/EN 61000-4-6
IEC/EN 61000-4-6; ANSI C63.4; ISO 7637-2; CISPR 16-1-2; CISPR 22 / EN55022; CISPR 32 / EN55032
ANSI C63.4; CISPR 16-1-2; ISO 7637-2; IEC/EN 61000-4-6; CISPR 22 / EN 55022; CISPR 32 / EN55032; CISPR 16-1-2
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC/EN 61000-4-8
ISO
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
IEC/EN 61000-4-2; ISO 10605; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-5(2005); ISO 7637-2; ISO 7637-2 (2004); ISO 16750-2
IEC/EN 61000-4-6; ANSI C63.4; ISO 7637-2; CISPR 16-1-2; CISPR 22 / EN55022; CISPR 32 / EN55032
ANSI C63.4; CISPR 16-1-2; ISO 7637-2; IEC/EN 61000-4-6; CISPR 22 / EN 55022; CISPR 32 / EN55032; CISPR 16-1-2
IEC/EN 61000-4-5; IEC/EN 61000-4-5 (2005); ISO 7637-2; ISO 7637-2 (2004); ISO 16750-2
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
IEC/EN 61000-4-2; ISO 10605; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-5(2005); ISO 7637-2; ISO 7637-2 (2004); ISO 16750-2
IEC/EN 61000-4-2; ISO 10605; ISO 10605 (2001); IEC/EN 61000-4-4
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
IEC/EN 61000-4-2; ISO 10605; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-5(2005); ISO 7637-2; ISO 7637-2 (2004); ISO 16750-2
IEC/EN 61000-4-5; IEC/EN 61000-4-5 (2005); ISO 7637-2; ISO 7637-2 (2004); ISO 16750-2
Other standards
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
IEC/EN 61000-4-6; ANSI C63.4; ISO 7637-2; CISPR 16-1-2; CISPR 22 / EN55022; CISPR 32 / EN55032
ANSI C63.4; CISPR 16-1-2; ISO 7637-2; IEC/EN 61000-4-6; CISPR 22 / EN 55022; CISPR 32 / EN55032; CISPR 16-1-2
CISPR 16-1-2Name not checked yet
CISPR 16-1-2; IEC/EN 61000-4-6
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurementCertificate says EN 55022. Probably the same standard; not checked against the EN document.
ANSI C63.4; CISPR 16-1-2; ISO 7637-2; IEC/EN 61000-4-6; CISPR 22 / EN 55022; CISPR 32 / EN55032; CISPR 16-1-2
Scope as published by A2LA
37 lines
ISO/IEC 17025
Active4727.01
The scope document we hold says it was valid until 2026-03-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Location
4-1-1, Ojimaminami, Honjo-shi, Saitama-ken, 367-8686, Japan, Honjo-shi, Saitama-ken, JP
36.24359, 139.19163
Open in MapsLabs with overlapping accredited scope in Japan
- TOYO Corporation Calibration LaboratoryTokyo 135-0042 · ~79 kmA2LAShares 4 accredited test methodsANSI C63.4CISPR 16-1-2ISO 10605
- OHTAMA CALIBRATION SERVICE Co.,Kanagawa · ~91 kmA2LAShares 3 accredited test methodsANSI C63.4CISPR 16-1-2ISO 10605
- UL Japan, Inc. - Kashima EMCChiba-ken, 289-0341 · ~101 kmA2LAShares 3 accredited test methodsANSI C63.4CISPR 16-1-2ISO 7637-2
- Samoto & Associates,Yokohama, Kanagawa · ~97 kmA2LAShares 2 accredited test methodsANSI C63.4CISPR 16-1-2
- UL Japan, Inc. Automotive Technology CenterMiyoshi-shi, Aichi · ~228 kmA2LAShares 2 accredited test methodsISO 10605ISO 7637-2
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.