TOYO Corporation Calibration Laboratory
1-1, Kiba 1-chome, Koto-ku, Tokyo 135-0042, Japan, Tokyo 135-0042, Japan
Visit website- Accredited standards
- 14
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 14 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series8
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
ISO4
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
Other standards2
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
CISPR 16-1-2
CISPR 16-1-2; IEC61000-3-2
IEC 61000-3-3; IEC 61000-3-2; IEC 61000-3-11; JIS C 61000-3-2; CISPR16-1-2; CISPR16-1-4; CISPR 16-1-4; ANSI C63.4
IEC61000-4-2; ISO 10605; CISPR16-1-3; CISPR16-4-1; CISPR 16-1-1
IEC/EN 61000-4-11; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-5 (2005); ISO 7637-2; ISO 7637-2 (2004); ISO 16750-2; JASO D 001
IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-5 (2005)
IEC61000-4-5; IEC61000-4-4; IEC61000-4-4
CISPR16-1-2; ANSI C63.4; IEC/EN 61000-4-6; CISPR16-1-2(2006)
CISPR16-1-2; ANSI C63.4; IEC/EN 61000-4-6; ISO11452-4; CISPR16-1-1
CISPR 16-1-2; IEC 61000-4-6; IEEE Std 1309; CISPR 25; IEC61000-4-6
IEC61000-4-6
CISPR16-1-2; IEC/EN 61000-4-11
ISO 7637-2; ISO 7637-2 (2004); ISO 16750-2; JASO D 001; IEC/EN 61000-4-11
CISPR 16-1-2; CISPR 22
ANSI C63.2; CISPR 16-1-1; CISPR 16-1-2; CISPR 25
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
33 lines
ISO/IEC 17025
Active2296.01
The scope document we hold says it is valid until 2027-06-30.
Location
1-1, Kiba 1-chome, Koto-ku, Tokyo 135-0042, Japan, Tokyo 135-0042, JP
35.68879, 139.73454
Open in MapsOther Locations
1 other site in this organization
Labs with overlapping accredited scope in Japan
- UL Japan, Inc. - Kashima EMCChiba-ken, 289-0341 · ~29 kmA2LAShares 5 accredited test methodsANSI C63.4CISPR 16-1-2IEC 61000-3-3
- OKI ENGINEERING CO.,Honjo-shi, Saitama-ken · ~79 kmA2LAShares 4 accredited test methodsANSI C63.4CISPR 16-1-2ISO 10605
- LAB SupportAzumino-shi, Nagano-ken · ~178 kmA2LAShares 4 accredited test methodsANSI C63.4CISPR 16-1-2ISO 10605
- OHTAMA CALIBRATION SERVICE Co.,Kanagawa · ~43 kmA2LAShares 3 accredited test methodsANSI C63.4CISPR 16-1-2ISO 10605
- Samoto & Associates,Yokohama, Kanagawa · ~28 kmA2LAShares 2 accredited test methodsANSI C63.4CISPR 16-1-2
Accreditation data refreshed from the A2LA register on .