Registers refreshed 2026-11-20.See refresh dates
Spain

ANAQUA, S.L. (Unipersonal)

Plaza Eduardo Urculo, 2-bajo, 33001, Oviedo, Spain

ENAC 780/LE1514ISO/IEC 17025Register refreshed 46 days ago

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
9
ENAC certificate
1
Site in our directory
1
ENAC accredited scope

What this lab is accredited for

Our reading of the ENAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 9 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.

EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EPA 350.2
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 11731Water quality - Enumeration of Legionella

Certificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.

ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 19458Water quality - Sampling for microbiological analysis
ISO 27888

Read from the scope as published by ENAC. Register refreshed 2026-10-10.

Scope as published by ENAC

6 lines
ENAC

ISO/IEC 17025

Active

780/LE1514

View scope

Accredited scope, certificate 780/LE1514

LineMethodMatrixRange
1UNE-EN ISO/IEC 17025:2017Aguas de consumo; Aguas continentales tratadas, aguas de captación para aguas de consumo y aguas subterráneas; Aguas residuales-
2SM 4500-H+ B; UNE-EN ISO 27888; SM 2130 B; EPA 350.2; SM 4500-Cl G; SM 4500-P E; SM 4500-NO-3 E; J. RodierAguas de consumo; Aguas continentales tratadas, aguas de captación para aguas de consumo y aguas subterráneasSee scope document
3SM 2130 B; UNE-EN 872; SM 4500-Norg B; EPA 350.2; SM 4500-Cl G; ISO 15705; SM 4500-P E; SM 4500-SO42- E; RD 509/1996Aguas continentales tratadas; aguas de captación para aguas de consumo; aguas subterráneasSee scope document
4SM 4500-H+ B; UNE-EN ISO 27888; UNE-EN 872; SM 4500-Norg B; SM 5210 D; EPA 350.2; ISO 15705; SM 4500-P E; SM 4500-NO-3 E; “Análisis de las aguas” J. Rodier; RD 509/1996Aguas residualesSee scope document
5ISO 6222; UNE-EN ISO 11731; SM 2550 B; SM 4500-Cl GAguas continentales tratadas, aguas de captación para aguas de consumo y aguas subterráneas; Aguas de consumo y aguas continentales tratadas; Aguas residualesSee scope document
6ISO 5667-5; UNE-EN ISO 19458; ISO 5667-10; RD 487/2022 Anexo VIAguas de consumo, aguas de captación para aguas de consumo y aguas continentales tratadas; Aguas residuales; AFCH y ACS (acumuladores/depósitos y puntos terminales); Sistemas de refrigeración (torres); Piscinas, spas, hidromasajes y similares; Fuentes ornamentales; Circuitos contraincendios-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Plaza Eduardo Urculo, 2-bajo, Oviedo, 33001, ES

43.35335, -5.87951

Open in Maps

Accreditation data refreshed from the ENAC register on .