Laboratorium Ochrony Środowiska Pracy
ul. Starzyńskiego 1, 08-110, Siedlce, Poland
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Laboratorium Ochrony Środowiska Pracy?
Claim this profile to keep it accurate.
Register record
- PCARefreshed
- AB 1037Active
Accredited standards
10Our reading of the PCA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
EN 14253Mechanical vibration - Measurement and evaluation of occupational exposure to whole-body vibration with reference to health - Practical guidanceCertificate says EN 14253+A1:2011. Probably the same standard; not checked against the EN document.
PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011
ISO 5349-1Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 1: General requirements
PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011
ISO 5349-2Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Part 2: Practical guidance for measurement at the workplace
PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011
ISO 7243Ergonomics of the thermal environment - Assessment of heat stress using the WBGT (wet bulb globe temperature) index
PN-EN ISO 7243:2018-01; PN-EN ISO 7730:2006; PN-EN ISO 7730:2006+Ap2:2016-04; PN-EN ISO 11079:2008+Ap1:2013; PN-Z-04008-7:2002+Az1:2004
ISO 7730Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
PN-EN ISO 7243:2018-01; PN-EN ISO 7730:2006; PN-EN ISO 7730:2006+Ap2:2016-04; PN-EN ISO 11079:2008+Ap1:2013; PN-Z-04008-7:2002+Az1:2004
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011
ISO 11079Ergonomics of the thermal environment - Determination and interpretation of cold stress when using required clothing insulation (IREQ) and local cooling effects
PN-EN ISO 7243:2018-01; PN-EN ISO 7730:2006; PN-EN ISO 7730:2006+Ap2:2016-04; PN-EN ISO 11079:2008+Ap1:2013; PN-Z-04008-7:2002+Az1:2004
PN-71/Z-04041Name not checked yet
PN-71/Z-04041; PN-76/Z-04045/02
PN-N-01307:1994Hałas - Dopuszczalne wartości hałasu w środowisku pracy - Wymagania dotyczące wykonywania pomiarów
PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011
PN-Z-04507:2022-05Ochrona czystości powietrza - Oznaczanie frakcji wdychalnej aerozolu na stanowiskach pracy metodą grawimetryczną
PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08
Scope as published by PCA
7 lines
ISO/IEC 17025
ActiveAB 1037
The scope document we hold says it is valid until 2029-04-23.
Accredited scope, certificate AB 1037
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | chemical | - | working environment (harmful factors – air); working environment (harmful and nuisance factors - noise, vibration, microclimate); working environment (harmful factors - air) | - |
| 2 | environmental | PN-N-01307:1994; PN-EN ISO 9612:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-2:2004/A1:2015-11; PN-EN 14253+A1:2011 | Workplace environment | 0.04 to 138 dB; m/s2 |
| 3 | environmental | PN-EN ISO 7243:2018-01; PN-EN ISO 7730:2006; PN-EN ISO 7730:2006+Ap2:2016-04; PN-EN ISO 11079:2008+Ap1:2013; PN-Z-04008-7:2002+Az1:2004 | Air | 10 to 40 oC |
| 4 | environmental | PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08 | Ambient air | 0.1 to 20.4 mg/m3 |
| 5 | chemical | PN-Z-04469:2025-02; PN-Z-04472:2015-10+Ap1:2015-12; PN-Z-04106-3:2002; PN-87-Z-04100/03; PN-Z-04502:2019-10 | Ambient air | 0.001 to 14.7 mg/m3; mg w próbce |
| 6 | chemical | PN-71/Z-04041; PN-76/Z-04045/02 | Air | 0.000125 to 6523 mg/m3 |
| 7 | chemical | Procedura Badawcza QLB-04 | Ambient air | 0.09 to 8107 mg/m3; ppm; mg w próbce |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Zakład Badań Środowiska Pracy Izabela GrabowskaWarszawa · ~82 kmPCAShares 6 accredited methods and materialsEN ISO 7243:2018-01PN-71/Z-04041PN-N-01307:1994
- TES LABORATORIUM Spółka z ograniczoną odpowiedzialnościąWarszawa · ~91 kmPCAShares 6 accredited methods and materialsPN-71/Z-04041PN-N-01307:1994PN-Z-04507:2022-05
- GRUPA EKOPROJEKTBielsko-Biała · ~345 kmPCAShares 6 accredited methods and materialsPN-71/Z-04041PN-N-01307:1994PN-Z-04507:2022-05
- Pracownia Badań Środowiska Pracy "Higiena Pracy" Marek SmoczyńskiJawor · ~437 kmPCAShares 6 accredited methods and materialsEN ISO 7243:2018-01PN-71/Z-04041PN-N-01307:1994
- Zakład Badań Środowiskowych Andrzej KropiwiecWarszawa-Wesoła · ~72 kmPCAShares 5 accredited methods and materialsEN ISO 7243:2018-01PN-Z-04507:2022-05Air
Accreditation data refreshed from the PCA register on .