DeltaTRAK
1236 Doker Dr, 95352, Modesto, CA, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 4020.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | -40 to 150 °C |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4020.01) Revised 12/30/2025 Page 2 of 2
SATELLITE
Shenzhen DTF Technology Development Co., Ltd.
No.12 Xi Hu Tang,
Ping Dong Community, Ping Di Street, Long Gang District, Shen Zhen, China
Steven Cheng Phone: 0086 755-28689466
CALIBRATION
I. Thermodynamics
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Temperature – Measuring
Equipment
(-40 to 0) ℃
(0 to 150) ℃
0.41℃
0.21℃
Comparison
calibration in fluid
____________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavi or of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 3 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- G.T. MICHELLI CO., LLC - STOCKTONStockton, CA · ~44 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Pleasanton, CAPleasanton, CA · ~77 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Anritsu AUS, CaliforniaMorgan Hill, CA · ~80 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- HCT AmericaMilpitas, CA · ~83 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Silicon Valley, CASan Jose, CA · ~86 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.