DeltaTRAK

1236 Doker Dr, 95352, Modesto, CA, United States

Visit website
A2LA 4020.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 4020.01 · 3 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--40 to 150 °C
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4020.01) Revised 12/30/2025 Page 2 of 2 SATELLITE Shenzhen DTF Technology Development Co., Ltd. No.12 Xi Hu Tang, Ping Dong Community, Ping Di Street, Long Gang District, Shen Zhen, China Steven Cheng Phone: 0086 755-28689466 CALIBRATION I. Thermodynamics Parameter/Equipment Range CMC2, 4 (±) Comments Temperature – Measuring Equipment (-40 to 0) ℃ (0 to 150) ℃ 0.41℃ 0.21℃ Comparison calibration in fluid ____________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavi or of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
3ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1236 Doker Dr, Modesto, CA, 95352, US

37.63934, -120.99689

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.