Servizi Tecnico Analitici
Via Albert Einstein 16, 20062, Cassano d'Adda, Italy
Visit website- Accredited standards
- 4
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 4 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.
APAT CNR IRSA 2060 Man 29 2003pH
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 11731Water quality - Enumeration of Legionella
ISO 19458Water quality - Sampling for microbiological analysis
UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 5130 Man 29 2003; APAT CNR IRSA 2090 B Man 29 2003; APAT CNR IRSA 4030 A2 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 3020 Man 29 2003; APAT CNR IRSA 4020 Man 29 2003; ISO 11731:2017
ISO 5667-5:2006; UNI EN ISO 19458:2006; APAT CNR IRSA 1030 Man 29 2003
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.
Scope as published by ACCREDIA
2 lines
ISO/IEC 17025
Active00963
Accredited scope, certificate 00963
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 5130 Man 29 2003; APAT CNR IRSA 2090 B Man 29 2003; APAT CNR IRSA 4030 A2 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 3020 Man 29 2003; APAT CNR IRSA 4020 Man 29 2003; ISO 11731:2017 | Waste water | 4 to 10 u.pH |
| 2 | ISO 5667-5:2006; UNI EN ISO 19458:2006; APAT CNR IRSA 1030 Man 29 2003 | Acque destinate al consumo umano da impianti di trattamento e da sistemi di distribuzione convogliato; Drinking waters from treatment works and piped distribution systems; Acque destinate al consumo umano; Drinking waters; Acque di scarico; Waste waters | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- BIO 7Castelvetro · ~60 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003ISO 5667-5:2006Waste water
- P.I.ECO S.r.l. Processi impianti ecologiciTerno d'Isola · ~18 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003Waste water
- LABORATORIO ANALISI E TECNOLOGIE AMBIENTALIMilano · ~23 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003Waste water
- Nuovo Istituto Italiano Sicurezza dei Giocattoli Srl - in breve Istituto Italiano Sicurezza dei Giocattoli Srl - in breve IISGCabiate · ~31 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003Waste water
- M.P. s.u.r.l.Cucciago · ~41 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003Waste water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.