United States

Equipment Services Group

3269 Hilton Road, 48220, Ferndale, MI, United States

Visit website
A2LA 2638.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 2638.01 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-0 to 300 V
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2638.01) 01/08/2026 Page 2 of 4 Parameter/Equipment Range CMC2, 4 (±) Comments Resistance – Generate3 (0 to 11) Ω (0 to 110) Ω (0 to 1.1) kΩ (0 to 11) kΩ 0.011 % + 0.023 Ω 0.011 % + 0.047 Ω 0.023 % + 0.58 Ω 0.030 % + 6.0 Ω Fluke 743B Thermocouple Simulation3 – Type J Type K Type T (-180 to -100) °C (-100 to 800) °C (800 to 1200) °C (-180 to -100) °C (-100 to 400) °C (400 to 1200) °C (1200 to 1300) °C (-180to -200) °C (-200 to 0) °C (0 to 400) °C 0.44 °C 0.34 °C 0.33 °C 0.55 °C 0.45 °C 0.44 °C 0.44 °C 1.2 °C 0.54 °C 0.43 °C Fluke 743B RTD Simulation3 – 100 Ω, Pt 3926 100 Ω, Pt 385 100 Ω, Pt 3916 (-180 to 0) °C (0 to 630) °C (-180 to 0) °C (0 to 400) °C (400 to780) °C (-180 to -190) °C (-190 to 0) °C (0 to 360) °C 0.26 °C 0.33 °C 0.24 °C 0.31 °C 0.51 °C 0.40 °C 0.24 °C 0.31 °C Fluke 743B
to 1300 °C
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2638.01) 01/08/2026 Page 3 of 4 III. Mechanical Parameter/Equipment Range CMC2 (±) Comments Pneumatic Gage Pressure3 – Gages & Transducers (0 to 200) psig 0.19 psig Fluke 743B & Fluke 700PD7 pressure transducer IV. Thermodynamics Parameter/Equipment Range CMC2, 5 (±) Comments Relative Humidity – Measure3 (11 to 90) % RH (90.1 to 95) % RH 1.9 % RH 2.6 % RH Vaisala temperature & humidity indicator Temperature – Measure3 (-100 to 200) °C (0 to 250) °C (251 to 400) °C (401 to 500) °C (501 to 750) °C (-40 to 125) °C 1.2 °C 1.4 °C 2.4 °C 2.4 °C 3.9 °C 0.78 °C Fluke 743B w/ Type TSLE TC Fluke 743B w/ type KSLE TC Fluke 743B w/ PRT V. Time & Frequency Parameter/Equipment Range CMC2, 5 (±) Comments Time – Measure3 (1 to 60) min 1.3 s Stopwatch ______________________________________________________________________ 1 This laboratory offers commercial calibration service and field calibration service.
0 to 200 psig
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2638.01) 01/08/2026 Page 4 of 4 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The measurands stated are generated with the Fluke 743B instruments. This capability is suitable for the calibration of the devices intended to measure the stated measurand in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a fraction /percentage of the reading plus a fixed floor specification. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
5ISO/IEC 17025:20 17; ANSI/NCSLI Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

3269 Hilton Road, Ferndale, MI, 48220, US

42.46059, -83.13465

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.