CEPRA CENTRO PROTEZIONE AMBIENTALE
Via del Tintoretto 6/2, 40033, Casalecchio di Reno, Italy
Visit website- Accredited standards
- 2
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 2 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
APAT CNR IRSA 2060 Man 29 2003pH
ISO 23695Water quality - Determination of ammonium nitrogen in water - Small-scale sealed tube method
APAT CNR IRSA 2060 Man 29 2003; APHA Standard Methods for Examination of Water and Wastewater 2540 C (2020); UNI ISO 23695:2023; APAT CNR IRSA 4020 Man 29 2003; ISPRA Man 117 2014; APAT CNR IRSA 3010 A + 3020 Man 29 2003; APAT CNR IRSA 2090 B Man 29 2003; CNR IRSA 1 Q 64 Vol 3 1985 + APAT CNR IRSA 2060 Man 29 2003; CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.
Scope as published by ACCREDIA
2 lines
ISO/IEC 17025
Active01358
Accredited scope, certificate 01358
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | APAT CNR IRSA 2060 Man 29 2003; APHA Standard Methods for Examination of Water and Wastewater 2540 C (2020); UNI ISO 23695:2023; APAT CNR IRSA 4020 Man 29 2003; ISPRA Man 117 2014; APAT CNR IRSA 3010 A + 3020 Man 29 2003; APAT CNR IRSA 2090 B Man 29 2003; CNR IRSA 1 Q 64 Vol 3 1985 + APAT CNR IRSA 2060 Man 29 2003; CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008 | Waste water | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. CEPRA CENTRO PROTEZIONE AMBIENTALE Srl
UNI CEI EN ISO/IEC 17025:2018
Allegato al certificato di accreditamento n. 01358 rev. 4 del 23/01/2025
Via del Tintoretto 6/2
40033 Casalecchio di Reno BO
Legenda/Note
Revisione: 9
Sede A
Data: 16/04/2025
pag. 2 di 2
Il simbolo (1), se presente, indica: "Materiale/Prodotto/Matrice" non previsto dal metodo ma assimilabile/The symbol (1), if present, means: Material/Product/Matrix not
provided for by the method but acceptable
Per la definizione della “categoria" di prova indicata nel titolo, si veda il Regolamento Generale ACCREDIA RG-02/For the definition of the test “category” indicated in the title,
see ACCREDIA General Regulation RG-02.
Il QRcode consente di accedere direttamente al sito www.accredia.it per verificare la validità dell'elenco prove e del certificato di accreditamento
rilasciato al laboratorio/The QRcode allows to directly access to the website www.accredia.it to verify the validity of the test list and of the
accreditation certificate issued to the laboratory.
L’eventuale simbolo “X” riportato nella colonna “O&I” indica che il laboratorio è accreditato anche per fornire opinioni e interpretazioni basate sui
risultati delle specifiche prove contrassegnate/Any "X" symbol in the "O&I" column indicates that the laboratory is also accredited to provide opinions
and interpretations based on the results of the specific marked tests.
L'eventuale simbolo (*) indica che è attiva una sospensione dell’accreditamento per la specifica attività riportata a fianco/Any symbol (*) indicates that
a suspension of accreditation is active for the specific activity shown next to it. | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- GREIT SRL - GRUPPO ECOLOGICO ITALIANOBologna · ~6 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003Waste water
- CHEMICALAB del Dott. Domenico GioviniModena · ~28 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003Waste water
- LAB 2000Nonantola · ~29 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003Waste water
- BIOCHEMIE LAB S.r.l.Campi Bisenzio · ~72 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003Waste water
- LoricaScandicci · ~80 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003Waste water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.