Trescal, Inc. - Winston-Salem
101 North Chestnut St, Suite 210, 27101, Winston-Salem, NC, United States
Visit website- Scope lines
- 12
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 12 scope lines.
A2LA certificate 1486.01 · 12 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.01) Revised 2/7/2025 Page 2 of 11
Parameter/Equipment
Range CMC2, 3 (±) Comments
DC Current – Measure
(0 to 100) nA
(0.1 to 1) µA
(1 to 10) µA
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
41 pA + 89 µA/A
41 pA + 24 pA/µA
40 pA + 24 pA/µA
82 pA + 22 pA/µA
6 nA + 24 nA/mA
53 nA + 21 nA/mA
0.53 µA + 37 nA/mA
10 µA + 0.11 mA/A
Agilent 3458A
Resistance – Generate
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(330 to 1099.999) Ω
(1.1 to 3.299 999) kΩ
(33 to 10.999 99) kΩ
(1 to 32.999 99) kΩ
(33 to 109.999) kΩ
(110 to 329.999) kΩ
(0.33 to 1.099 99) MΩ
(1.1 to 3.299 00) MΩ
(3.3 to 10.9999) MΩ
(11 to 32.9999) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
1.2 mΩ + 24 µΩ/Ω
1.5 mΩ + 24 µΩ/Ω
1.9 mΩ + 22 µΩ/Ω
4.1 mΩ + 22 µΩ/Ω
9.1 mΩ + 22 µΩ/Ω
41 mΩ + 22 µΩ/Ω
92 mΩ + 22 µΩ/Ω
0.41 Ω + 22 µΩ/Ω
0.9 Ω + 22 µΩ/Ω
8.4 Ω + 26 µΩ/Ω
14 Ω + 26 µΩ/Ω
93 Ω + 48 µΩ/Ω
0.4 kΩ + 0.1 mΩ/Ω
4.4 kΩ + 0.2 mΩ/Ω
16 kΩ + 0.4 mΩ/Ω
0.35 MΩ + 2.4 mΩ/Ω
4.4 MΩ + 12 mΩ/Ω
Fluke 5520A
Resistance – Measure
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
55 µΩ + 15 µΩ/Ω
0.52 mΩ + 13 µΩ/Ω
0.53 mΩ + 10 µΩ/Ω
5.3 mΩ + 10 µΩ/Ω
53 mΩ + 11 µΩ/Ω
2.3 Ω + 17 µΩ/Ω
0.1 kΩ + 55 µΩ/Ω
1 kΩ + 0.52 mΩ/Ω
10 kΩ + 5.1 mΩ/Ω
Agilent 3458A
Electrical Calibration
of Thermocouple
Indicating Devices –
Type B
(600 to 800) °C
(800 to 1000) °C
(1000 to 1550) °C
(1550 to 1820) °C
0.35 °C
0.27 °C
0.24 °C
0.27 °C
Fluke 5520A | ||
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.01) Revised 2/7/2025 Page 3 of 11
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of
Thermocouple Indicating
Devices – (cont)
Type C
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(0 to 150) °C
(150 to 650) °C
(650 to 1000) °C
(1000 to 1800) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.21 °C
0.25 °C
0.4 °C
0.68 °C
0.4 ᵒC
0.13 ᵒC
0.11 ᵒC
0.13 ᵒC
0.17 ᵒC
0.22 ᵒC
0.13 ᵒC
0.11 ᵒC
0.14 ᵒC
0.18 ᵒC
0.27 ᵒC
0.14 ᵒC
0.13 ᵒC
0.21 ᵒC
0.32 ᵒC
0.32 ᵒC
0.18 ᵒC
0.15 ᵒC
0.15 ᵒC
0.22 ᵒC
0.46 ᵒC
0.28 ᵒC
0.27 ᵒC
0.33 ᵒC
0.38 ᵒC
0.29 ᵒC
0.3 ᵒC
0.37 ᵒC
0.51 ᵒC
0.21 ᵒC
0.15 ᵒC
0.13 ᵒC
Fluke 5520A | to 1800 °C |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.01) Revised 2/7/2025 Page 4 of 11
Parameter/Equipment
Range CMC2, 3 (±) Comments
Capacitance – Generate
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
9 pF + 4 pF/nF
10 pF + 4 pF/nF
13 pF + 4 pF/nF
15 pF + 2 pF/nF
0.1 nF + 2 pF/nF
0.15 nF + 2 pF/nF
0.5 nF + 2 pF/nF
1.5 nF + 2 nF/µF
5 nF + 2nF/µF
14 nF + 2 nF/µF
60 nF + 3 nF/µF
0.2 µF + 4 nF/µF
0.63 µF + 4 nF/µF
2 µF + 4 µF/mF
7 µF + 4 µF/mF
38 µF + 2.5 µF/mF
90 µF + 6 µF/mF
Fluke 5520A
Electrical Calibration of
RTD Indicators –
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
Pt 385, 200 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to 0) °C
(> 0 to 100) °C
(> 100 to 260) °C
(> 260 to 300) °C
(> 300 to 400) °C
(> 400 to 600) °C
(> 600 to 630) °C
0.042 °C
0.041 °C
0.057 °C
0.073 °C
0.081 °C
0.097 °C
0.19 °C
0.041 °C
0.041 °C
0.057 °C
0.073 °C
0.081 °C
0.097 °C
0.033 °C
0.042 °C
0.049 °C
0.065 °C
0.073 °C
0.19 °C
0.034 °C
0.033 °C
0.042 °C
0.097 °C
0.11 °C
0.11 °C
0.13 °C
Fluke 5520A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.01) Revised 2/7/2025 Page 5 of 11
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of
RTD Indicators – (cont)
Pt 385, 500 Ω
Pt 385, 1 kΩ
PtNi 385, 120 Ω
Cu427, 10 Ω
(-200 to -80) °C
(> -80 to 100) °C
(> 100 to 260) °C
(> 260 to 400) °C
(> 400 to 600) °C
(> 600 to 630) °C
(-200 to 0) °C
(> 0 to 100) °C
(> 100 to 260) °C
(> 260 to 300) °C
(> 300 to 600) °C
(> 600 to 630) °C
(-80 to 100) °C
(> 100 to 260) °C
(-100 to 260) °C
0.034 °C
0.042 °C
0.05 °C
0.065 °C
0.073 °C
0.089 °C
0.026 °C
0.033 °C
0.042 °C
0.049 °C
0.057 °C
0.19 °C
0.066 °C
0.11 °C
0.24 °C
Fluke 5520A
Parameter/Range
Frequency CMC2, 3 (±) Comments
AC Voltage – Generate
(1 to 33) mV
(33 to 330) mV
330 mV to 3.3 V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 200) kHz
(200 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 200) kHz
(200 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 200) kHz
(200 to 500) kHz
5.5 µV + 0.64 µV/mV
5 µV + 0.12 µV/mV
5 µV + 0.16 µV/mV
5.6 µV + 0.8 µV/mV
12 µV + 2.8 µV/mV
47 µV + 6.4 µV/mV
47 µV + 6.4 µV/mV
14 µV + 0.24 µV/mV
24 µV + 87 nV/mV
11 µV + 0.13 µV/mV
35 µV + 0.28 µV/mV
47 µV + 0.64 µV/mV
0.11 mV + 1.6 µV/mV
0.11 mV + 1.6 µV/mV
0.12 mV + 0.24 mV/V
88 µV + 0.12 mV/V
99 µV + 0.15 mV/V
0.12 mV + 0.24 mV/V
0.29 mV + 0.56 mV/V
1.1 mV + 1.9 mV/V
1.1 mV + 1.9 mV/V
Fluke 5520A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.01) Revised 2/7/2025 Page 6 of 11
Parameter/Range
Frequency CMC2, 3 (±) Comments
AC Voltage – Generate
(cont)
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 10 kHz
1.3 mV + 0.24 mV/V
0.94 mV + 0.12 mV/V
1.6 mV + 0.18 mV/V
1.4 mV + 0.28 mV/V
3.7 mV + 0.72 mV/V
6.8 mV + 0.15 mV/V
10 mV + 0.16 mV/V
12 mV + 0.2 mV/V
13 mV + 0.24 mV/V
93 mV + 1.6 mV/V
88 mV + 0.24 mV/V
Fluke 5520A
AC Voltage – Measure
(1 to 10) mV
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
6.1 µV + 0.0003 mV/mV
4.1 µV + 0.0002 mV/mV
4.2 µV + 0.0003 mV/mV
4.9 µV + 0.001 mV/mV
9 µV + 0.005 mV/mV
45 µV + 0.04 mV/mV
12 µV + 0.000 07 mV/mV
2.7 µV + 0.000 07 mV/mV
11 µV + 0.000 14 mV/mV
12 µV + 0.0003 mV/mV
17 µV + 0.0008 mV/mV
47 µV + 0.003 mV/mV
0.12 mV + 0.01 mV/mV
3.8 mV + 0.02 mV/mV
0.12 mV + 0.000 07 V/V
0.1 mV + 0.000 07 V/V
0.11 mV + 0.000 14 V/V
0.12 mV + 0.0003 V/V
0.17 mV + 0.0008 V/V
0.47 mV + 0.003 V/V
1.2 mV + 0.01 V/V
38 mV + 0.015 V/V
1.2 mV + 0.000 07 V/V
1 mV + 0.000 07 V/V
1 mV + 0.000 14 V/V
1.2 mV + 0.0003 V/V
1.7 mV + 0.0008 V/V
4.7 mV + 0.003 V/V
12 mV + 0.01 V/V
0.38 V + 0.015 V/V
Agilent 3458A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.01) Revised 2/7/2025 Page 7 of 11
Parameter/Range
Frequency CMC2, 3 (±) Comments
AC Voltage – Measure
(cont)
(10 to 100) V
(100 to 1000) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
13 mV + 0.0002 V/V
11 mV + 0.0002 V/V
11 mV + 0.0002 V/V
13 mV + 0.0004 V/V
21 mV + 0.001 V/V
57 mV + 0.004 V/V
0.17 V + 0.015 V/V
99 mV + 0.0004 V/V
85 mV + 0.0004 V/V
98 mV + 0.0006 V/V
0.14 V + 0.0012 V/V
0.27 V + 0.003 V/V
Agilent 3458A
AC Current – Measure
Up to 100 μA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
57 nA + 4 nA/µA
45 nA + 1.5 nA/µA
40 nA + 0.64 nA/µA
0.43 µA + 0.0041 mA/mA
0.31 µA + 0.0016 mA/mA
0.26 µA + 0.000 67 mA/mA
0.25 µA + 0.000 37 mA/mA
0.26 µA + 0.000 67 mA/mA
0.63 µA + 0.0042 mA/mA
1.8 µA + 0.0056 mA/mA
2.4 µA + 0.0041 mA/mA
2.3 µA + 0.0016 mA/mA
2.3 µA + 0.000 67 mA/mA
2.3 µA + 0.000 37 mA/mA
2.3 µA + 0.000 67 mA/mA
4.5 µA + 0.0041 mA/mA
16 µA + 0.0056 mA/mA
42 µA + 0.004 mA/mA
30 µA + 0.0015 mA/mA
25 µA + 0.0006 mA/mA
24 µA + 0.0003 mA/mA
25 µA + 0.0006 mA/mA
62 µA + 0.004 mA/mA
0.18 mA + 0.0055 mA/mA
0.42 mA + 0.0041 A/A
0.3 mA + 0.0017 A/A
0.26 mA + 0.0009 A/A
0.27 mA + 0.0011 A/A
0.37 mA + 0.0031 A/A
0.92 mA + 0.01 A/A
Agilent 3458A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.01) Revised 2/7/2025 Page 8 of 11
Parameter/Range
Frequency CMC2, 3 (±) Comments
AC Current – Generate
(29 to 330) µA
330 μA to 3.3 mA
(3.3 to 33) mA
(33 to 330) mA
330 mA to 1.1 A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
Clamp-On Ammeters:
(3.2 to 200) A
(16 to 1000) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
0.13 µA + 1.6 nA/µA
0.12 µA + 1.2 nA/µA
0.11 µA + 1 nA/µA
0.19 µA + 2.4 nA/µA
0.35 µA + 6.4 nA/µA
0.70 µA + 13 nA/µA
0.65 µA + 1.6 µA/mA
0.45 µA + 1 µA/mA
0.39 µA + 0.8 µA/mA
0.69 µA + 1.6 µA/mA
2.9 µA + 1.6 µA/mA
3.4 µA + 8 µA/mA
6.4 µA + 1.4 µA/mA
4 µA + 0.72 µA/mA
2.7 µA + 0.32 µA/mA
3.7 µA + 0.64 µA/mA
7.7 µA + 1.6 µA/mA
14 µA + 3.2 µA/mA
65 µA + 1.4 µA/mA
42 µA + 0.72 µA/mA
29 µA + 0.31 µA/mA
68 µA + 0.8 µA/mA
0.13 mA + 1.6 µA/mA
0.27 mA + 3.2 µA/mA
0.56 mA + 1.4 mA/A
0.22 mA + 0.4 mA/A
2.4 mA + 4.8 mA/A
11 mA + 20 mA/A
1.7 mA + 1.4 mA/A
0.61 mA + 0.48 mA/A
6.1 mA + 4.8 mA/A
26 mA + 20 mA/A
3.1 mA + 0.48 mA/A
4 mA + 0.8 mA/A
74 mA + 24 mA/A
15 mA + 0.96 mA/A
17 mA + 1.2 mA/A
0.27 A + 24 mA/A
7.6 mA + 3.1 mA/A
38 mA + 3.1 mA/A
Fluke 5520A
5520A w/:
10-turn coil
50-turn coil | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.01) Revised 2/7/2025 Page 9 of 11
II. Mechanical
Parameter/Equipment
Range CMC 2, 4, 6 (±) Comments
Vacuum – Measure &
Measuring Equipment
(1 to 30) in·Hg
0.000 52 in·Hg +
0.000 16 in·Hg/in·Hg
Pressurements T3550/3
DWT
Pressure – Measure &
Measuring Equipment
Pneumatic
Hydraulic
(5 to 400) in·H2O
(8 to 17) psia
(-15 to 15) psig
(-15 to 50) psig
(> 50 to 150) psig
(-15 to 100) psig
(> 100 to 300) psig
(-15 to 330) psig
(> 330 to 1000) psig
(> 1000 to 10 000) psig
(1000 to 5000) psig
(5000 to 10 000) psig
0.007 in·H2O +
0.000 16 in·H2O/in·H2O
0.01 %
0.003 psig
0.0044 psig
0.008 %
0.0083 psi
0.008 %
0.027 psi
0.008 %
0.17 psi +
0.000 16 psi/psi
1.1 psi
0.11 %
Pressurements T3550/3
DWT
Mensor CPC6050 with
sensor range (8 to 17) psia
Mensor CPC6050 with
sensor range (-15 to 15)
psig
Mensor CPC6050 with
sensor range (-15 to 150)
psig
Mensor CPC6050 with
sensor range (-15 to 300)
psig
Mensor CPC6050 with
sensor range (-15 to 1000)
psig
Pressurements W2200-3-P
DWT
Additel ADT681
Crystal 10KPSIXP2I
III. Thermodynamics
Parameter/Equipment
Range CMC2, 4 (±) Comments
Temperature –
Measure
(-197 to 660) °C
(> 660 to 1200) °C
0.0036 °C + 0.000 019 x
TChange from -197
2 °C + 0.0031 x TChange
from 660
ADT286-ST, 5699 SPRT
ADT286-ST, Type-B
thermocouple | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.01) Revised 2/7/2025 Page 10 of 11
Parameter/Equipment
Range CMC2, 4 (±) Comments
Temperature –
Measuring
Equipment
(-80 to 110) °C
(> 110 to 300) °C
(500 to 1200) °C
0.01 °C + 0.000 006 x
TChange from -80
0.026 °C + 0.000 032 x
TChange from 110
1.9 °C + 0.0027 x TChange
from 500
ADT286-ST, 5699,
SPRT, calibration baths
ADT286-ST, Type-B
thermocouple. calibration
furnace
Relative Humidity –
Measuring
Equipment
(10 to 95) % RH
0.61 % RH
Thunder Scientific 2500S
humidity generator
IV. Time & Frequency
Parameter/Equipment
Range CMC2, 4 (±) Comments
Frequency –
Measuring
Equipment
10 mHz to 120 Hz
120 Hz to 1.2 kHz
(1.2 to 12) kHz
(12 to 120) kHz
120 kHz to 1.2 MHz
(1.2 to 2.0) MHz
6.8 µHz + 1.9 µHz/Hz
0.24 mHz + 1.9 µHz/Hz
2.3 mHz + 1.9 µHz/Hz
23 mHz + 1.9 µHz/Hz
0.23 Hz + 1.9 µHz/Hz
2.3 Hz + 1.9 µHz/Hz
Fluke 5520A
Frequency – Measure
1 mHz to 225 MHz
5.8 µHz + 4.1 µHz/Hz
Agilent 53131A
Stopwatches &
Timers (Totalize
Method)
100 ms to 24 hrs
37 ms
Agilent 53131A, Fluke
5520A
_____________________________________________
1 This laboratory offers commercial calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.01) Revised 2/7/2025 Page 11 of 11
3 The measurands stated are generated using the indicated instrument (see Comments). This capability is
suitable for the calibration of the devices intended to measure the measurand in the ranges
indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction of the
reading plus a fixed floor specification.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 In the statement of CMC, % is defined as percent of reading unless otherwise noted. | ||
| 12 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- SIMCO Electronics - GreensboroGreensboro, NC · ~41 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Charlotte, NCCornelius, NC · ~88 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- MSI-Viking GageDanville, VA · ~94 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- MSI-Viking Gage, LLC.Durham, NC · ~121 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Troxler Electronic Laboratories, Inc.Research Triangle Park, NC · ~126 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.