Troxler Electronic Laboratories, Inc.

3008 E. Cornwallis Rd., 27709, Research Triangle Park, NC, United States

Visit website
A2LA 3260.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
9
A2LA certificate
1
Sites in our directory
4
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 9 scope lines.

A2LA certificate 3260.01 · 9 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2-Gyratory Compactor; Concrete Type B Air Meter Measurement Bowl
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3260.01) Revised 04/02/2026 Page 2 of 8 Parameter/Equipment Range CMC2 (±) Comments Locations6 Calibration of Angle Measurement System of the Gyratory Compactor Using the RAM3 (1.0 to 1.3)° 2.1 x 10-2 ° RAM RTP, HOU, ORL Gyratory Compactor Mold Internal Diameter3 (149.0 to 151.0) mm 1.0 x 10-2 mm Bore micrometer RTP, HOU, ORL, RAN Gyratory Compactor Ram Head and End Plate External Diameter3 (149.0 to 150.0) mm 1.8 x 10-2 mm External micrometer RTP, HOU, ORL, RAN Gyratory Compactor Mold Height (245.0 to 255.0) mm 0.015 mm CMM RTP Gyratory Compactor Mold Wall Thickness (7.0 to 8.0) mm 0.13 mm CMM, bore micrometer RTP Gyratory Compactor Mold Inside Surface, Ram Head and End Plate Surface Rq Value Up to 5.00 µm 0.20 µm Surface texture tester RTP AFLS1 Rapid Internal Angle Measurement Calibration Tube, Dihedral Angle (1.0 to 1.3)° 1.0 x 10-2 ° CMM RTP Concrete Type B Air Meter Measurement Bowl Volume (0.20 to 0.30) ft3 8.8 x 10-3 % Air in Concrete Equivalent water volume ORL, FMY Concrete Type B Air Meter Measurement Bowl Diameter-to- Height Ratio 0.75 to 1.25 3.9 x 10-5 Caliper, depth gauge ORL, FMY
See scope document
3-Slump Mold; Blocks; Portable Nuclear Gauge Calibration System
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3260.01) Revised 04/02/2026 Page 3 of 8 Parameter/Equipment Range CMC2 (±) Comments Locations6 Slump Mold Upper Opening Diameter (3.74 to 4.25) in 1.3 x 10-2 in Caliper ORL, FMY Slump Mold Base Opening Diameter (7.75 to 8.25) in 1.5 x 10-2 in Caliper ORL, FMY Slump Mold Height (11.75 to 12.25) in 8.4 x 10-3 in Caliper, depth gauge ORL, FMY Slump Mold Wall Thickness (0.07 to 0.13) in 4.7 x 10-3 in Micrometer ORL, FMY II. Mechanical Parameter/Equipment Range CMC2, 4 (±) Comments Location6 Calibration of Rotational Frequency of the Gyratory Compactor 3 (0 to 35) RPM 0.15 RPM Laser tachometer RTP, HOU, ORL, RAN Density – Primary Density Blocks (1760 to 2725) kg/m3 0.029 % rdg CMM, weight determinations RTP Density – Secondary Density Blocks3 (1760 to 2725) kg/m3 0.47 % rdg Master gauge RTP, HOU, ORL, RAN, FMY 7 Density – TroxlerTM, 8 Tracker Portable Nuclear Gauge Calibration System3 (1740 to 2620) kg/m3 (1.0 x 10-5D2 – 4.0 x 10-3D + 0.65) % rdg Master gauge RTP, ORL
See scope document
4-Water
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3260.01) Revised 04/02/2026 Page 4 of 8 Parameter/Equipment Range CMC2, 4 (±) Comments Location6 Water Mass Per Unit Volume – Secondary Moisture Blocks (370 to 823) kg/m3 4.4 % rdg Master gauge RTP Water Mass Per Unit Volume – Tertiary Moisture Blocks3 (555 to 615) kg/m3 3.9 % rdg Master gauge RTP, HOU, ORL, RAN, FMY 7 Water Mass Per Unit Volume – TroxlerTM, 8 Tracker Portable Nuclear Gauge Calibration System3 (110 to 375) kg/m 3 6.8 % rdg Master gauge RTP, ORL Master Gauge Calibration, Density Measurement System (1760 to 2725) kg/m3 0.11 % rdg Primary density blocks RTP Master Gauge Calibration, Water Mass Per Unit Volume Measurement System (373 to 804) kg/m3 4.0 % rdg Secondary water blocks RTP Client Surface Moisture/Density Nuclear Gauges, Density Measurement System 3 – Backscatter Other Positions (1740 to 2626) kg/m 3 (1740 to 2626) kg/m 3 1.3 % rdg (1.3 x 10 -5D2 – 0.0048D + 0.70) % rdg Secondary density blocks RTP, HOU, ORL, RAN, FMY 7
See scope document
5-Client Surface Moisture/Density Nuclear Gauges; Client Thin Layer Density Nuclear Gauges
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3260.01) Revised 04/02/2026 Page 5 of 8 Parameter/Equipment Range CMC2, 4 (±) Comments Location6 Client Surface Moisture/Density Nuclear Gauges, Density Measurement System3 – Backscatter Other Positions (1850 to 2550) kg/m 3 (1740 to 2620) kg/m3 1.3 % rdg (-2.3 x 10 -3D + 1.8) % rdg Troxler TM, 8 tracker portable nuclear gauge calibration system RTP, ORL Client Surface Moisture/Density Nuclear Gauges, Moisture System 3 (0 to 615) kg/m3 5.1 % rdg Tertiary moisture blocks RTP, HOU, ORL, RAN, FMY 7 Client Surface Moisture/Density Nuclear Gauges, Moisture System 3 (0 to 375) kg/m3 4.1 % rdg TroxlerTM, 8 tracker portable nuclear gage calibration system RTP, ORL Client Thin Layer Density Nuclear Gauges 3 – For Low Density Top Layer, High Density Bottom Layer For High Density Top Layer, Low Density Bottom Layer Density: (1740 to 2585) kg/m 3 Top Layer Thickness: (25.4 to 101.6) mm Density: (1740 to 2585) kg/m 3 Top Layer Thickness: (25.4 to 101.6) mm (0.0020T 2 – 0.18T + 7.8) % rdg (-0.0012T 2 + 0.095T – 0.21) % rdg Secondary density blocks and primary thin layer plates RTP, HOU, ORL, RAN, FMY 7 Calibration of Load Cell for Gyratory Compactor Pressure Calibration (790 to 5010) lbf 7.1 lbf Master load cell RTP
1740 to 2585 kg/m3
6-applied load; Rockwell C Hardness; Air; Water Content; soil; concrete; liters
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3260.01) Revised 04/02/2026 Page 6 of 8 Parameter/Equipment Range CMC2 (±) Comments Location6 Scales and Balances3 1500 g to 30 kg 0.000 29 % of applied load Standard weights RTP, HOU, RAN Scales and Balances3 Up to 30 kg 0.000 29 % of applied load Standard weights ORL, FMY7 Calibration of Pressure System of the Gyratory Compactor 3 (590 to 610) kPa 3.6 kPa Load cell RTP, HOU, ORL, RAN Rockwell C Hardness of Gyratory Mold, End Plate, and Ram (45 to 70) Rockwell C Hardness 1.6 Rockwell C Hardness Hardness meter RTP Calibration of Pressure System of the Concrete Type B Air Meter (0 to 15) % Air 0.12 % Air The pressure dial on the concrete air meter measures pressure, but is calibrated to correlate air content of the concrete specimen being measured to pressure ORL, FMY Calibration of the Calcium Carbide Gas Pressure Tester (the “Speedy”) (0 to 20) % Water Content 0.062 % Water Content The pressure dial on the Speedy measures pressure, but is calibrated to correlate water content of the soil specimen being measured to pressure ORL, FMY Volume – Measuring Bowl of Concrete Volumetric Air Content Meter ≥ 2 liters 0.062 % rdg Thermometer, scale ORL, FMY
See scope document
7-concrete
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3260.01) Revised 04/02/2026 Page 7 of 8 Parameter/Equipment Range CMC2 (±) Comments Location6 Percent Air Content – Concrete Volume Divided by Measuring Bowl Volume (0 to 15) % Air 0.070 % Air Thermometer, scale ORL, FMY Ratio of Calibrated Cup Volume Divided by Measuring Bowl Volume 1 % ± 0.04 % of the Volume of the Measuring Bowl 0.0058 % rdg Thermometer, scale ORL, FMY Ratio of the Meter Top Section Volume Divided by Measuring Bowl Volume Ratio ≥ 1.2 0.0019 rdg Thermometer, scale ORL, FMY Ratio of Measuring Bowl Diameter Divided by Measuring Bowl Height Ratio ≥ 1 But Less Than or Equal to 1.25 0.040 rdg Thermometer, scale, bore micrometer ORL, FMY ____________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent ex panded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, D is the nuclear gauge measurement depth in millimeters, and T is the top layer thickness in millimeters. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
-
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3260.01) Revised 04/02/2026 Page 8 of 8 6 The locations of the laboratories that can perform the calibration are given by a three-letter code with valid to dates given in the table below: Location Code Valid to Dates 3008 E. Cornwallis Rd., Research Triangle Park, NC 27709 RTP April 30, 2028 2500 Central Parkway, Suite L, Houston, TX 77092 HOU July 31, 2027 531 Holts Lake Ct, Apopka, FL 32703 ORL May 31, 2027 11300 Sanders Dr., Rancho Cordova, CA 95742 RAN November 30, 2026 1681 Benchmark Ave, Fort Myers, FL 33905 FMY7 May 31, 2027 Please click here to return to page 1. 7 This location does not perform field service activity. 8 “Troxler” is a trademark registered to Troxler Electronic Laboratories, Inc.
9ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

3008 E. Cornwallis Rd., Research Triangle Park, NC, 27709, US

35.89238, -78.86589

Open in Maps

Other Locations

3 other sites in this organization