C & C Technologies

2455 Reliance Avenue, P. O. Box 1137, 27539, Apex, NC, United States

Visit website
A2LA 1345.01A2LA 1345.02ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
6
A2LA certificates
2
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 6 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

Read from the A2LA scope documents we downloaded on 2025-12-02 and 2026-10-27. Register refreshed 2026-11-20.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

1345.01

The scope document we hold says it is valid until 2027-08-31.

View scope

Accredited scope, certificate 1345.01

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--
2-Relative Humidity; Temperature; Time
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1345.01) 10/21/2025 Page 2 of 2 Parameter/Equipment Range CMC2 (±) Comments Relative Humidity3 - Humidity Meters, Probes, Thermo-Hygrometers, Data Logger (11 to 33) % RH (33 to 75) % RH (75 to 97) % RH 2.8 % RH 3.1 % RH 4.4 % RH Using humidity meters & environment chamber Relative Humidity3 – Environment Chamber Controllers & Probes (11 to 33) % RH (33 to 75) % RH (75 to 97) % RH 2.8 % RH 3.1 % RH 4.4 % RH Using humidity meters Temperature3 – Digital Thermometers, Mechanical Thermometer, probes. (-70 to 300) °C 0.3 °C Using Agilent 34970A w/ RTD & dry block Temperature3 – Environment Chamber Controllers & Probes (-70 to 300) °C 0.3 °C Using Agilent 34970A w/ RTD III. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Stopwatches 5 s to 24 h 0.5 s Direct comparison with NIST traceable audio time signals. ____________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
See scope document
3ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA

ISO/IEC 17025

Active

1345.02

The scope document we hold says it is valid until 2027-08-31.

View scope

Accredited scope, certificate 1345.02

LineMethodMatrixRange
1ASTM B117; ISO/IEC 17025:2017; IEC 17025; IEC 60068-2-1; IEC 60068-2-2Environmental Simulation11 to 97 % RH
2IEC 60068-2-27; IEC 60068-2-6; IEC 60068-2-64; MIL-STD-810; MIL-STD-202-to 12000 lbf
3ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.