Nanjing Shengxun Information Technology Co.,
A9 #8 Bailongjiang East Street, Jianye District, NanjingCity, Jiangsu Province, China, Nan Jing, People's Republic of China, Nan Jing, China
- Accredited standards
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
RSS-102
ISO/IEC 17025:2017; FCC CFR 47 Part 15B; ANSI C63.4:2014; FCC CFR 47 Part 18; FCC MP-5:1986; ICES-001; ICES-003; FCC CFR 47 Part 15C; ANSI C63.10-2020/Cor1-2023; ANSI C63.10a-2024; ANSI C63.30:2021; FCC CFR 47 Part 15E; FCC KDB 905462 D02 UNII DFS Compliance Procedures New Rules; RSS-GEN; RSS-210; RSS-216; RSS-247; RSS-248
ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26-2015; ANSI C63.26:2015; IEEE Std 1528:2013; ANSI C63.19:2011; ANSI C63.19:2019
IEEE Std 1528; IEEE Std C95.1; ANSI C95.1; FCC CFR 47 Part 20 (using ANSI C63.19:2011 and ANSI C63.19:2019); ANSI/TIA-5050; RSS-102; RSS-102.NS.MEAS; RSS-102; RSS-102.SAR.MEAS; IEC/IEEE 62209-1528; IEEE Std C95.3; RSS-HAC; FCC CFR 47 Part 22 (cellular); FCC CFR 47 Part 24; FCC CFR 47 Part 25 (below 3GHz); FCC CFR 47 Part 27; ANSI/TIA-603-E; TIA-102.CAAA-E; FCC CFR 47 Part 22 (non-cellular); FCC CFR 47 Part 90 (using ANSI C63.26:2015); FCC CFR 47 Part 95; FCC CFR 47 Part 97; FCC CFR 47 Part 101; Part 73; Part 74 (below 3GHz); ANSI C63.26-2015; FCC CFR 47 Part 96 (using ANSI C63.26:2015); RSS-130; RSS-132; RSS-133; RSS-139; RSS-140; RSS-192; RSS-195; RSS-197; RSS-198; RSS-199
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active7650.01
The scope document we hold says it is valid until 2027-11-30.
Accredited scope, certificate 7650.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; FCC CFR 47 Part 15B; ANSI C63.4:2014; FCC CFR 47 Part 18; FCC MP-5:1986; ICES-001; ICES-003; FCC CFR 47 Part 15C; ANSI C63.10-2020/Cor1-2023; ANSI C63.10a-2024; ANSI C63.30:2021; FCC CFR 47 Part 15E; FCC KDB 905462 D02 UNII DFS Compliance Procedures New Rules; RSS-GEN; RSS-210; RSS-216; RSS-247; RSS-248 | Radio and Telecommunications Terminal Equipment (R&TTE); Information Technology Equipment (ITE) | - |
| 2 | IEEE Std 1528; IEEE Std C95.1; ANSI C95.1; FCC CFR 47 Part 20 (using ANSI C63.19:2011 and ANSI C63.19:2019); ANSI/TIA-5050; RSS-102; RSS-102.NS.MEAS; RSS-102; RSS-102.SAR.MEAS; IEC/IEEE 62209-1528; IEEE Std C95.3; RSS-HAC; FCC CFR 47 Part 22 (cellular); FCC CFR 47 Part 24; FCC CFR 47 Part 25 (below 3GHz); FCC CFR 47 Part 27; ANSI/TIA-603-E; TIA-102.CAAA-E; FCC CFR 47 Part 22 (non-cellular); FCC CFR 47 Part 90 (using ANSI C63.26:2015); FCC CFR 47 Part 95; FCC CFR 47 Part 97; FCC CFR 47 Part 101; Part 73; Part 74 (below 3GHz); ANSI C63.26-2015; FCC CFR 47 Part 96 (using ANSI C63.26:2015); RSS-130; RSS-132; RSS-133; RSS-139; RSS-140; RSS-192; RSS-195; RSS-197; RSS-198; RSS-199 | - | - |
| 3 | ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26-2015; ANSI C63.26:2015; IEEE Std 1528:2013; ANSI C63.19:2011; ANSI C63.19:2019 | - | to 40000 MHz |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
NANJING SHENGXUN INFORMATION TECHNOLOGY CO., LTD.
Nanjing, People’s Republic of China
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 22nd day of December 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 7650.01
Valid to November 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- DEKRA Testing and Certification (Suzhou) Co.,Suzhou, Jiangsu ProvinceA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-102
- DEKRA TESTING SERVICES (ANHUI) CO.,Hefei, Anhui ProvinceA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-102
- Eurofins TA Technology (Shanghai) Co.,Shanghai 201201A2LAShares 2 accredited test methodsANSI C63.4:2014RSS-102
- SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen BranchShenzhen, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-102
- SGS-CSTC Standards Technical Services (Suzhou) Co.,SuzhouA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-102
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.