DEKRA TESTING SERVICES (ANHUI) CO.,
Room 101, 1st floor, No.7 building, Smart Science Park Phase 5, No. 8213, Fanhua Avenue, Economic and Technological Development District, Hefei, Anhui Province, 230091, People's Republic of China, Hefei, Anhui Province, China
Visit website- Accredited standards
- 44
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 44 standard numbers and the 30 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series8
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
CISPR7
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national
National versions in the same scope
AS/NZS CISPR 15national version with changes
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national
National versions in the same scope
AS/NZS CISPR 32identical to it
CNS 15936identical to it
VCCI-CISPR 32probably the same standard; matched by number only
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC 61326 series7
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-2-4
IEC 61326-2-5
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
ETSI6
ETSI EN 300 386
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-52
EN5
EN 50383
EN 50385
EN 50566
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
IEC5
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 62493Exclusion
Limits written next to it
EN 62493 (excluding clause 5)
CISPR 16 series3
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
CISPR 16-2-2Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-2: Methods of measurement of disturbances and immunity - Measurement of disturbance power
CISPR 16-2-3Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
Other standards3
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
RSS-102
CFR 47, FCC Part 15 Subpart B; ANSI C63.4:20141; CFR 47, FCC Part 18; MP-5:1986; CISPR 16-2-1; EN 55016-2-1; GB/T 6113.201; CISPR 16-2-3; EN 55016-2-3; GB/T 6113.203; ICES-001; ICES-003; ICES-005; GB/T 9254; CNS 13438; GB/T 9254.1; CISPR 14-1; EN 55014-1; EN IEC 55014-1; BS EN 55014-1; GB 4343.1; SASO CISPR 14-1; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; BS EN 61000-6-3; GB 17799.3; SASO IEC 61000-6-3; IEC 61000-6-4; EN IEC 61000-6-4; EN 61000-6-4; BS EN 61000-6-4: GB 17799.4; SASO IEC 61000-6-4; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; GB/T 17626.2; SANS 61000-4-2; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; GB/T 17626.4; SANS 61000-4-4; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5; GB/T 17626.5; SANS 61000-4-5; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; BS EN IEC 61000-4-11; GB/T 17626.11; SANS 61000-4-11; IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6-1; BS EN IEC 61000-6-1; GB/T 17799.1; SASO IEC 61000-6-1; IEC 61000-6-2; EN 61000-6-2; EN IEC 61000-6-2; BS EN IEC 61000-6-2; GB/T 17799.2; SASO IEC 61000-6-2; CISPR 11; EN 55011; BS EN 55011; GB 4824; SASO CISPR 11; IEC 60601-1-2; EN 60601-1-2; BS EN 60601-1-2; YY 9706.102
CFR 47, FCC Part 15 Subpart B; ANSI C63.4:20141; CFR 47, FCC Part 18; MP-5:1986; CISPR 16-2-1; EN 55016-2-1; GB/T 6113.201; CISPR 16-2-3; EN 55016-2-3; GB/T 6113.203; ICES-001; ICES-003; ICES-005; GB/T 9254; CNS 13438; GB/T 9254.1; CISPR 14-1; EN 55014-1; EN IEC 55014-1; BS EN 55014-1; GB 4343.1; SASO CISPR 14-1; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; BS EN 61000-6-3; GB 17799.3; SASO IEC 61000-6-3; IEC 61000-6-4; EN IEC 61000-6-4; EN 61000-6-4; BS EN 61000-6-4:GB 17799.4; SASO IEC 61000-6-4; CISPR 16-2-2; EN 55016-2-2; GB/T 6113.202; GB/T13837; CNS 13439
CISPR 14-2; EN 55014-2; EN IEC 55014-2; BS EN 55014-2; GB/T 4343.2; SASO CISPR 14-2; GB/T 9254; CNS 13438; GB/T 13837; CNS 13439; CISPR 24; EN 55024; GB/T 17618; IEC 61326-1; EN 61326-1; BS EN 61326-1; GB/T 18268.1; SASO IEC 61326-1; IEC 61326-2-1; EN 61326-2-1; BS EN 61326-2-1; GB/T 18268.21; SASO IEC 61326-2-1; IEC 61326-2-2; EN 61326-2-2; BS EN 61326-2-2; GB/T 18268.22; SASO IEC 61326-2-2; IEC 61326-2-3; EN 61326-2-3; BS EN 61326-2-3; GB/T 18268.23; SASO IEC 61326-2-3; IEC 61326-2-4; EN 61326-2-4; BS EN 61326-2-4; GB/T 18268.24; IEC 61326-2-5; EN 61326-2-5; BS EN 61326-2-5; GB/T 18268.25; IEC 61326-2-6; EN 61326-2-6; BS EN 61326-2-6; GB/T 18268.26; ETSI EN 300 386; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-52; CISPR 15; EN 55015; EN IEC 55015; AS/NZS CISPR 15; BS EN IEC 55015; GB/T 17743; SASO CISPR 15; IEC 61547; EN 61547; BS EN 61547; GB/T 18595; SASO IEC 61547; CISPR 32; EN 55032; AS/NZS CISPR 32; VCCI-CISPR 32; BS EN 55032; SASO CISPR 32; CNS 15936; GB/T 9254.1; CISPR 35; EN 55035; BS EN 55035; GB/T 9254.2
CISPR 24; EN 55024; GB/T 17618; IEC 61326-1; EN 61326-1; BS EN 61326-1; GB/T 18268.1; SASO IEC 61326-1; IEC 61326-2-1; EN 61326-2-1; BS EN 61326-2-1; GB/T 18268.21; SASO IEC 61326-2-1; IEC 61326-2-2; EN 61326-2-2; BS EN 61326-2-2; GB/T 18268.22; SASO IEC 61326-2-2; IEC 61326-2-3; EN 61326-2-3; BS EN 61326-2-3; GB/T 18268.23; SASO IEC 61326-2-3; IEC 61326-2-4; EN 61326-2-4; BS EN 61326-2-4; GB/T 18268.24; IEC 61326-2-5; EN 61326-2-5; BS EN 61326-2-5; GB/T 18268.25; IEC 61326-2-6; EN 61326-2-6; BS EN 61326-2-6; GB/T 18268.26; ETSI EN 300 386; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-52; CISPR 15; EN 55015; EN IEC 55015; AS/NZS CISPR 15; BS EN IEC 55015; GB/T 17743; SASO CISPR 15; IEC 61547; EN 61547; BS EN 61547; GB/T 18595; SASO IEC 61547; CISPR 32; EN 55032; AS/NZS CISPR 32; VCCI-CISPR 32; BS EN 55032; SASO CISPR 32; CNS 15936; GB/T 9254.1; CISPR 35; EN 55035; BS EN 55035; GB/T 9254.2; CFR 47, FCC Parts 15 C, E, F; ANSI C63.10:2020; FCC KDB Publication 905462 D02 (v02), April 8, 2016); ANSI C63.10:2013; ANSI/USEMCSC C63.10‐2020/Cor 1‐2023; ANSI C63.10-2020 + Corrigendum 1- 2023 + Amendment 1-2024; FCC Parts 22 (cellular), 24, 25 (below 3 GHz), 27, 74; ANSI/TIA-603-E-2016; TIA-102.CAAA-E-2016; ANSI C63.26:2015; FCC Parts 22 (non-cellular), 90 (below 3 GHz), 95(below 3 GHz), 96, 97 (below 3 GHz), 101 (below 3 GHz)
ANSI C95.1; ANSI C95.3; IEEE Std 1528-2013; RSS-102; RSS-102.SAR.MEAS; EN 50383; BS EN 50383; EN 50385; BS EN 50385; IEEE 62209-1528; BS IEC/IEEE 62209-1528; IEC/IEEE 62209-1528; EN IEC/IEEE 62209-1528; BS EN IEC/IEEE 62209-1528; EN 62311; EN IEC 62311; BS EN IEC 62311; EN 62479; BS EN 62479; EN 62493; BS EN 62493; EN 50663; BS EN 50663; EN 50665; BS EN 50665; EN 50566; BS EN 50566; ACMA Radiocommunications (Electromagnetic Radiation-Human Exposure) Standard 2014; AS/NZS 2772.1; AS/NZS 2772.2; ARPANSA Radiation Protection Series No.3; Standard for Limiting Exposure to Radiofrequency Fields – 100 kHz to 300 GHz Radiation Protection Series S-1; ARIB STD-T56; MIC Notice No.88; IEC TR 63170; IEC/IEEE 63195-1; IEC/IEEE 63195-2; RSS-102; RSS-102.IPD.MEAS
ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020; FCC KDB 905462 D02 (v02), April 8, 2016; ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015; IEEE Std 1528:2013
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
9 lines
ISO/IEC 17025
Active6579.01
The scope document we hold says it is valid until 2028-01-31.
Labs with overlapping accredited scope in China
- DEKRA Testing and Certification (Suzhou) Co.,Suzhou, Jiangsu ProvinceA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-102
- Eurofins TA Technology (Shanghai) Co.,Shanghai 201201A2LAShares 2 accredited test methodsANSI C63.4:2014RSS-102
- SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen BranchShenzhen, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-102
- SGS-CSTC Standards Technical Services (Suzhou) Co.,SuzhouA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-102
- Shenzhen Huatongwei International Inspection Co.,ShenzhenA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 24
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.