United States

The Modal Shop Inc, An Amphenol Company

10310 AeroHub Blvd,, 45215, Cincinnati, OH, United States

Visit website
A2LA 2649.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 2649.01 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-94 to 134 dB
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2649.01) Revised 1/17/2025 Page 2 of 4 Parameter/Equipment Frequency CMC2 (±) Comments Condenser/Array Microphone w/ Preamp - Sensitivity (20 to 1000) Hz (1001 to 10 000) Hz (10 001 to 16 000) Hz (16 001 to 20 000) Hz 0.25 dB (1/4”) 0.25 dB (1/2”) 0.30 dB (1/4”) 0.25 dB (1/2”) 0.30 dB (1/4”) 0.30 dB (1/2”) 0.35 dB (1/4”) 0.60 dB (1/2”) Microphone (Comparison Method) II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC 2, 3, 5 (±) Comments DC Voltage – Measure 100 mV to 100 V 0.12 % DMM, oscilloscope function generator, calibrated capacitor, DAQ AC Voltage Ratio – Measure 100 mV to 10 V 0.12 % DMM, oscilloscope function generator, calibrated capacitor, DAQ III. Mechanical Parameter/Equipment Range CMC2, 3 (±) Comments Impulse Force Hammer (1 to 5000) lbf 2.5 % Data acquisition card accelerometer w/ calibrated masses Force Sensor/Load Cell (1 to 3.5) lbf 2.0 % Data acquisition card w/ calibrated masses Shock Accelerometer Calibration (20 to 10 000) g 2.2 % Data acquisition card shock reference shock exciter
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2649.01) Revised 1/17/2025 Page 3 of 4 Parameter/Equipment Frequency CMC2, 3 (±) Comments Vibration Laser Primary – Sensitivity Magnitude Low Frequency Mid to High Frequency (0.5 ≤ f ≤ 10) Hz 5 Hz (5 < f < 100) Hz (100 ≤ f ≤ 160) Hz (160 < f ≤ 1000) Hz (1000 < f ≤ 5000) Hz (5000 < f ≤ 15 000) Hz (15 000 < f ≤ 20 000) Hz 0.30 % 1.0 % 0.50 % 0.20 % 0.50 % 0.70 % 1.5 % 2.0 % Data acquisition card w/ air bearing low frequency shaker Data acquisition card w/ primary laser reference air bearing shaker f represents the calibration frequency Vibration Laser Primary – Sensitivity Phase Low Frequency Mid to High Frequency (0.5 ≤ f ≤ 10) Hz (5 ≤ f < 5000) Hz (5000 ≤ f ≤ 20 000) Hz 0.5° 0.7° 2.1° Data acquisition card w/ air bearing low frequency shaker Data acquisition card w/ primary laser reference air bearing shaker Vibration General Purpose – Sensitivity Magnitude Mid to High Frequency Low Frequency Mid to High Frequency – using Secondary Standard (5 ≤ f ≤ 10) Hz (10 < f < 100) Hz 100 Hz (100 < f ≤ 920) Hz (920 < f ≤ 5000) Hz (5000 < f ≤ 10 000) Hz (10 000 < f ≤ 15 000) Hz (15 000 < f ≤ 20 000) Hz (0.5 ≤ f ≤ 1) Hz (1 < f ≤ 10) Hz (10 ≤ f < 100) Hz 100 Hz (100 < f ≤ 920) Hz (920 < f ≤ 2000) Hz 1.7 % 1.2 % 0.75 % 1.0 % 1.4 % 1.9 % 2.2 % 2.8 % 1.1 % 0.8 % 3.0 % 1.3 % 1.5 % 3.0 % Data acquisition card w/ 396C10/C11 air bearing shaker w/ low frequency long stroke shaker w/ optical reference w/ MB CAL 50
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2649.01) Revised 1/17/2025 Page 4 of 4 ___________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. Parameter/Equipment Frequency CMC 2, 3 (±) Comments Vibration General Purpose –Sensitivity Phase Mid to High Frequency Low Frequency (5 ≤ f < 100) Hz (100 ≤ f < 5000) Hz (5000 ≤ f ≤ 20 000) Hz (0.5 ≤ f ≤ 10) Hz 1.5° 1.3° 2.8° 1.0° Data acquisition card w/ 396C10/C11 air bearing shaker w/ low frequency long stroke shaker w/ optical reference Calibration of Portable Vibration Calibrator (5 ≤ f ≤ 10) Hz (10 < f ≤ 30) Hz (30 < f < 100) Hz 100 Hz (100 < f < 2000) Hz (2000 ≤ f ≤ 10 000) Hz 4.0 % 3.0 % 1.5 % 1.0 % 1.5 % 4.0 % DMM, signal conditioner, standard accelerometer
5ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.