The Modal Shop Inc, An Amphenol Company
10310 AeroHub Blvd,, 45215, Cincinnati, OH, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 2649.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | 94 to 134 dB |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2649.01) Revised 1/17/2025 Page 2 of 4
Parameter/Equipment
Frequency
CMC2 (±)
Comments
Condenser/Array
Microphone w/ Preamp -
Sensitivity
(20 to 1000) Hz
(1001 to 10 000) Hz
(10 001 to 16 000) Hz
(16 001 to 20 000) Hz
0.25 dB (1/4”)
0.25 dB (1/2”)
0.30 dB (1/4”)
0.25 dB (1/2”)
0.30 dB (1/4”)
0.30 dB (1/2”)
0.35 dB (1/4”)
0.60 dB (1/2”)
Microphone
(Comparison Method)
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC
2, 3, 5 (±)
Comments
DC Voltage – Measure
100 mV to 100 V
0.12 %
DMM, oscilloscope function
generator, calibrated capacitor,
DAQ
AC Voltage Ratio –
Measure
100 mV to 10 V
0.12 %
DMM, oscilloscope function
generator, calibrated capacitor,
DAQ
III. Mechanical
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Impulse Force Hammer
(1 to 5000) lbf
2.5 %
Data acquisition card
accelerometer w/ calibrated
masses
Force Sensor/Load Cell
(1 to 3.5) lbf
2.0 %
Data acquisition card w/
calibrated masses
Shock Accelerometer
Calibration
(20 to 10 000) g
2.2 %
Data acquisition card
shock reference shock exciter | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2649.01) Revised 1/17/2025 Page 3 of 4
Parameter/Equipment
Frequency
CMC2, 3 (±)
Comments
Vibration Laser Primary
– Sensitivity Magnitude
Low Frequency
Mid to High
Frequency
(0.5 ≤ f ≤ 10) Hz
5 Hz
(5 < f < 100) Hz
(100 ≤ f ≤ 160) Hz
(160 < f ≤ 1000) Hz
(1000 < f ≤ 5000) Hz
(5000 < f ≤ 15 000) Hz
(15 000 < f ≤ 20 000) Hz
0.30 %
1.0 %
0.50 %
0.20 %
0.50 %
0.70 %
1.5 %
2.0 %
Data acquisition card
w/ air bearing low
frequency shaker
Data acquisition card
w/ primary laser
reference air bearing
shaker
f represents the
calibration frequency
Vibration Laser Primary
– Sensitivity Phase
Low Frequency
Mid to High
Frequency
(0.5 ≤ f ≤ 10) Hz
(5 ≤ f < 5000) Hz
(5000 ≤ f ≤ 20 000) Hz
0.5°
0.7°
2.1°
Data acquisition card
w/ air bearing low
frequency shaker
Data acquisition card
w/ primary laser
reference air bearing
shaker
Vibration General
Purpose – Sensitivity
Magnitude
Mid to High
Frequency
Low Frequency
Mid to High
Frequency –
using Secondary
Standard
(5 ≤ f ≤ 10) Hz
(10 < f < 100) Hz
100 Hz
(100 < f ≤ 920) Hz
(920 < f ≤ 5000) Hz
(5000 < f ≤ 10 000) Hz
(10 000 < f ≤ 15 000) Hz
(15 000 < f ≤ 20 000) Hz
(0.5 ≤ f ≤ 1) Hz
(1 < f ≤ 10) Hz
(10 ≤ f < 100) Hz
100 Hz
(100 < f ≤ 920) Hz
(920 < f ≤ 2000) Hz
1.7 %
1.2 %
0.75 %
1.0 %
1.4 %
1.9 %
2.2 %
2.8 %
1.1 %
0.8 %
3.0 %
1.3 %
1.5 %
3.0 %
Data acquisition card
w/ 396C10/C11 air
bearing shaker
w/ low frequency
long stroke shaker
w/ optical reference
w/ MB CAL 50 | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2649.01) Revised 1/17/2025 Page 4 of 4
___________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
Parameter/Equipment
Frequency
CMC
2, 3 (±)
Comments
Vibration General
Purpose –Sensitivity
Phase
Mid to High
Frequency
Low Frequency
(5 ≤ f < 100) Hz
(100 ≤ f < 5000) Hz
(5000 ≤ f ≤ 20 000) Hz
(0.5 ≤ f ≤ 10) Hz
1.5°
1.3°
2.8°
1.0°
Data acquisition card
w/ 396C10/C11 air
bearing shaker
w/ low frequency
long stroke shaker
w/ optical reference
Calibration of Portable
Vibration Calibrator
(5 ≤ f ≤ 10) Hz
(10 < f ≤ 30) Hz
(30 < f < 100) Hz
100 Hz
(100 < f < 2000) Hz
(2000 ≤ f ≤ 10 000) Hz
4.0 %
3.0 %
1.5 %
1.0 %
1.5 %
4.0 %
DMM, signal
conditioner, standard
accelerometer | ||
| 5 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Tektronix, Inc. - CincinnatiCincinnati, OH · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Mitutoyo America CorporationWest Chester, OH · ~27 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - DaytonSpringboro, OH · ~56 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Western Environmental a Division of Controlled Environment Systems (CES)Springboro, OH · ~56 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- American Testing Services,Miamisburg, OH · ~60 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.