Registers refreshed 2026-11-08.See refresh dates
Poland

Weterynaryjne Laboratorium Diagnostyczne AlphaLab prof. Andrzej Gaweł

ul. Księgarska 1, 51-180, Wrocław, Poland

PCA AB 1908ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
8
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 8 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO 4833-1Microbiology of the food chain - Horizontal method for the enumeration of microorganisms - Part 1: Colony count at 30 °C by the pour plate technique
ISO 6579-1Microbiology of the food chain - Horizontal method for the detection, enumeration and serotyping of Salmonella - Part 1: Detection of Salmonella spp.
ISO 6888-2Microbiology of the food chain - Horizontal method for the enumeration of coagulase-positive staphylococci (Staphylococcus aureus and other species) - Part 2: Method using rabbit plasma fibrinogen agar medium
ISO 10272-2Microbiology of the food chain - Horizontal method for detection and enumeration of Campylobacter spp. - Part 2: Colony-count technique
ISO 11290-1Microbiology of the food chain - Horizontal method for the detection and enumeration of Listeria monocytogenes and of Listeria spp. - Part 1: Detection method
ISO 11290-2Microbiology of the food chain - Horizontal method for the detection and enumeration of Listeria monocytogenes and of Listeria spp. - Part 2: Enumeration method
ISO 16649-2Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of beta-glucuronidase-positive Escherichia coli - Part 2: Colony-count technique at 44 degrees C using 5-bromo-4-chloro-3-indolyl beta-D-glucuronide
ISO 21528-2Microbiology of the food chain - Horizontal method for the detection and enumeration of Enterobacteriaceae - Part 2: Colony-count technique

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.

Scope as published by PCA

4 lines
PCA

ISO/IEC 17025

Active

AB 1908

The scope document we hold says it is valid until 2028-08-07.

View on PCA

Accredited scope, certificate AB 1908

LineMethodMatrixRange
1-biological items and materials for testing, food, animal feedstuffs and objects from food production area; biological items and materials for testing; biological items and materials for testing, food, water, animal feedstuffs and objects from food production area
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1908 Scope of accreditation No. AB 1908 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No. AB 1908 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie /Issue 2 z/of 30.07.2025 KIEROWNIK DZIAŁU AKREDYTACJI BADAŃ I CERTYFIKACJI ŻYWNOŚCI HANNA TUGI Niniejszy dokument jest załącznikiem do C ertyfikatu Akredytacji Nr AB 1908 z dnia 08.08.2024 r. Cykl akredytacji od 08.08.2024 r. do 07.08.2028 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No. AB 1908 of 08.08.2024 Accreditation cycle from 08.08.2024 to 07.08.2028 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No. 2, 30.07.2025 1/5 Nazwa i adres / Name and address WETERYNARYJNE LABORATORIUM DIAGNOSTYCZNE AlphaLab prof. Andrzej Gaweł ul. Księgarska 1, 51-180 Wrocław Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - B/3; B/22; B/55; B/57 - D/3 - Badania biologiczne i biochemiczne obiektów i materiałów biologicznych przeznaczonych do badań, żywności, pasz dla zwierząt i obiektów obszaru produkcji żywności / Biological and biochemical test s of biological items and materials for testing, food, animal feedstuffs and ob jects from food production area - Badania kliniczne weterynaryjne obiektów i materiałów biologicznych przeznaczonych do badań / Clinic al, veterinary tests of biological items and materials for testing - K/3; K/22; K/28, K/55; K/57 - Badania mikrobiologiczne materiałów biologicznych przeznaczonych do badań, żywności, wody, pasz dla zwierząt i obiektów obszaru produkcji żywności / Microbiological tests of biological items and m aterials for testing, food, water, animal feedstuffs and objects from food production area Wersja strony / Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl AB 1908
-
2PN-EN ISO 4833-1:2013+Ap1:2016+A1:2022-06; PN- EN ISO 21528-2:2017-08; PN-ISO 16649-2:2004; PN-EN ISO 6888-2:2022+A1:2024-02; PN- EN ISO 11290-2:2017-07; PN- EN ISO 10272-2: 2017-10+ A1:2023-08; PN- EN ISO 11290-1:2017-07; PN-EN ISO 6579-1:2017-04+ A1:2020-09; ISO TR 6579-3:2014; PBZ-1 wyd. 1 z dn. 01.03.2024 r. opracowana na podstawie instrukcji producenta testu; PBZ-2 wyd. 1 z dn. 01.03.2024 opracowana na podstawie instrukcji testuPasza; Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością; Wymazy z powierzchni ograniczonej i nieograniczonej szablonem-
3-Water
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1908 Wydanie nr 2, 30.07.2025 3/5 Przedmiot badań/wyrób Rodzaj działalności/badane cechy/ metoda Dokumenty odniesienia Próbki pobrane na etapie produkcji pierwotnej, w tym materiał biologiczny: - narządy wewnętrzne zwierząt - wymazy z narządów - jaja (z etapu produkcji pierwotnej) - jaja wylęgowe - zamarłe zarodki - pisklęta - puch - kał - wymazy podeszwowe - mekonium z wykładziną - wymazy - kurz - woda Obecność DNA Salmonella spp. Metoda real-time PCR PBB-11 wyd. 1 z dn. 01.03.2024 r. opracowana na podstawie instrukcji producenta testu Wersja strony: A
-
4Normy; Instrukcje Głównego Lekarza WeterynariiFood products-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Księgarska 1, Wrocław, 51-180, PL

51.12631, 16.97820

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.