Registers refreshed 2026-11-20.See refresh dates
United States

Touchstone Systems & Services

1817 Porter Street SW, 49519, Wyoming, MI, United States

Visit website
A2LA 560.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
51
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 51 standard numbers and the 14 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM34
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM B368
ASTM B487Standard Test Method for Measurement of Metal and Oxide Coating Thickness by Microscopical Examination of Cross Section
ASTM B537
ASTM D522
ASTM D523Standard Test Method for Specular Gloss
ASTM D610
ASTM D617
ASTM D642
ASTM D714
ASTM D790Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
ASTM D870
Show all 34
ASTM D880
ASTM D1005
ASTM D1308
ASTM D1654
ASTM D1735
ASTM D1737
ASTM D1939
ASTM D2248
ASTM D2794
ASTM D3359
ASTM D3363
ASTM D3574Standard Test Methods for Flexible Cellular Materials - Slab, Bonded, and Molded Polyurethane Foams
ASTM D4003
ASTM D4060
ASTM D4138
ASTM D4587
ASTM D5276
ASTM D5402
ASTM D5487
ASTM D7091
ASTM E1537
ASTM G85
ISO5
ISO 1172Textile-glass-reinforced plastics - Prepregs, moulding compounds and laminates - Determination of the textile-glass and mineral-filler content using calcination methods
ISO 1183-1Plastics - Methods for determining the density of non-cellular plastics - Part 1: Immersion method, liquid pycnometer method and titration method
ISO 2685Aircraft - Environmental test procedure for airborne equipment - Resistance to fire in designated fire zones
ISO 3795Road vehicles, and tractors and machinery for agriculture and forestry - Determination of burning behaviour of interior materials
ISO 4892-3Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps
IEC4
IEC 20653
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 61215
IEC 61646
IEC 60068 series4
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat

Certificate says IEC 68-2-2. Probably the same standard; not checked against the EN document.

IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock

Certificate says IEC 68-2-27. Probably the same standard; not checked against the EN document.

IEC 60068-2-29

Certificate says IEC 68-2-29. Probably the same standard; not checked against the EN document.

IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
Other standards4
BS 5852
DIN 50021
DIN 75220
EN 1021-2

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

560.01

The scope document we hold says it is valid until 2027-05-31.

View scope

Accredited scope, certificate 560.01

LineMethodMatrixRange
1RTCA/DO-160 C/D/E/F/G/H, Section 1-6; MIL-STD-202F; MIL-STD-810 C/D/E/F/G/H, Method 501, Method 502, Method 507; SAE J1211; IEC 68-2-2; IEC 60068-2-2; IEC 60068-2-38; IEC 61215; IEC 61646; GM9505P; GMW 14124; GM9132P; GMW 3217; GM2210M; DC-10611; PF9688; FORD 00.00EA-D11-1; FORD WSS-M15P34-D/E; NISSAN NES M 0007; MITSUBISHI ESX60210 4.3; NISSAN NES MO 131; DIN 75220; GM4465P; GM4350M; ASTM D1735, D2247, D4585; HES D2016-99A, HES D6501-03, HES D2021; FORD WSS-M15P34-D; ASTM D4587, G154; FLTM BI 104; ISO 4892-3; SAE J2412Textile-100 to 150 °C
2ASTM B117; ASTM B537; ASTM D610; ASTM D714; ASTM G85; GM4350M; GM4298P; GM4476P; GM9540P; RTCA/DO-160 C/D/E/F/G/H; MIL-STD-202F; MIL-STD-810 C/D/E/F/G/H; SAE J1211; PARKHAN P21- CPE-023 Rev.00; CHRYSLER LP-463-PB-10-01CHG.C; MS-PB-45-2 CHG.V; FORD FLTM BI 103-01; FRTLINER 49-00005 Rev.6; HES D2003-03B Rev.4; HES D2016-99A; HES D6501-03; HES D2021-99 C Rev.1; HES D6001-71; NISSAN 54400 NDS00; NISSAN NES M 0007; TSH6524G; Toyota TSH1552G; CEMS GT-7D; DIN 50021; Volvo STD 1027.14; ASTM B368; GM4372M; GM4476M; JIS H 8502-99; TSH6500G; HES D600-1-71; HES D2003-05B Rev.6; HES 2016-99A; HES D6501-03; TS430-1-4; GES 43226; WSB-MIP83-B1; WSB-MIP83-B2; WSB-MIP83-B3; WSB-MIP83-B4; DVM-0008RG Ver3; FRTLINER 49-00039 Rev A; FORD WSS-M1P83-C1/C2; RTCA/DO-160 C/D/E/F/G/H; MIL-STD-810 C/D/E/F/G/H; ISO 1183-1; ASTM D790; GMW 3235; SAE J1756; ISO 1172; SAE J400; MIL-STD-202F; GMW 3431; IEC 60529; SAE J575-to 70000 ft
3ASTM D870; ASTM D2248; IEC 60529; FLTM BI 104-01; GM4431M; HES D2016-99A; HES D6501-03; Toyota TSH1505G; RTCA/DO-160 C/D/E/F/G/H; MIL-STD-810 C/D/E/F/G/H; MIL-STD-202F; IEC 20653; SAE J994; WSS-M2P188-C1; ASTM D642; ASTM D3574; STRYKER ES-0668; STRYKER ES-0703; GM9502P; GM9150P; GM 4350M; ASTM D3363; HES D2016-99A; HES D6501-03 C Rev.2; NISSAN NES M 0007; GM9506P; GM9071P; GMW 14289; ASTM D3359; ASTM D1654; LP 63PB 15 01 CHG A; FLTM BI 104-01; FLTM BI 106-01; HES D2016-99; HES D 6501-03 C Rev. 2; DAIMLER DBL 7399; MIL-M-13231; ASTM D4060; SAE J365; SAE J948; RTCA/DO-160 C/D/E/F/G/H; MIL-STD-810 C/D/E/F/G/H; HES D6501-03 C Rev.2; HES D2016; FREIGHTLINER 49-00023; ASTM D1939; ASTM D1308; ASTM D5402; GM4350M; GM9500; GM9501; GM9517P; GM9900P; GMN 10033; GMW 14334; GMW 14444; NES M0007; SAE J1351; FLTM BN 112; FLTM BI 113-to 5000 lbs
4GM9033P; HES D2016-99A; NISSAN NES M 0007; FLTM BN 107-1; JIS K 5400; ASTM D2794; ASTM D5276; ASTM D880; ASTM D4003; ASTM D617; DAIMLER VOA621-402; PACCAR CMT0033; ASTM D1654; CEM GT-7D; ASTM B487; ASTM D1005; ASTM D4138; ASTM D7091; HES D6501; ASTM D523; ASTM D522; ASTM D1737; GM9509P; GMW 15891; FLM BO 131; SAE J1351; IPC-A-610F; GMW3172-DRBTR; RTCA/DO-160 C/D/E/F/G/H; MIL-STD-810 C/D/E/F/G/H; MIL-STD-202F; SAE J1211; GM9110P; GM9123P; GMW 3172; PF9688; FORD 00.00EA-D11-1; DC-10611; ASTM D5487; IEC 68-2-27; IEC 68-2-29; MIL-STD-901--50 to 150 °C
5CALIFORNIA TB117; CPAI-83; 16 CFR 1632; ISO 2685; 3795; JIS D1201; FMVSS 302 HES C206; DBL 5404; TSM0500G; BSDM0500; GMW3232; WSS-M15P4-1; ESE97B-1011014-AA; GB8410-2006; CMVSS 302; ISO 3795; DBL 5307.10; VCS5031; GM9070P (superseded 2011)2; SAE J369; FED TEST METHOD 5903.1; FED TEST METHOD 5906; FED STD 191A (VERT); FED STD 191 (HORIZ); FAA 25.853 APPENDIX F; PART 1(b)(5); POWER PLANT No. 3: AC 20-135; NFPA 260; NFPA 261; NFPA 101 (Sec 10.3); NFPA 701 UFAC TEST SERIES; ASTM E1537; E1353; RTCA/DO-160 F/G/H; Section 26; RTCA/DO-204-204; EN 1021-2; BS 5852; UL 94; BAC 5331; Boeing D6-81926 (except section 5.6.9 (Odor and Fungus)); Airbus L00716172Furniture Seating; Walls / Tops; Mattress; Foams; Films; PCB’s; Fabrics; Composites; Pneumatic / Servo PLC Driven Aircraft; Boot / Seal / Duct Lifecycle, in Combination with Extreme Temperature Internal and External with Pressure Cycling Screening (ESS), Vibration Profiles with Or Without Temperature and RH Using Customer QTP’s Engineering Design Requirements-
6

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited TOUCHSTONE SYSTEMS & SERVICES Wyoming, MI for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 28th day of April 2025. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 0560.01 Valid to May 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1817 Porter Street SW, Wyoming, MI, 49519, US

42.91326, -85.70570

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.