51
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 51 standard numbers and the 16 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI25
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 440
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-52
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-13
Show all 25
ETSI EN 302 502
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
ETSI EN 303 687
ETSI TS 134 121-1
ETSI TS 136 521-1
ETSI TS 137 144
ETSI TS 137 544
ETSI TS 138 101-1
ETSI TS 138 101-3
ETSI TS 138 521-1
ETSI TS 138 521-3
ETSI TS 151 010-1
EN6
EN 50360
EN 50364
EN 50385
EN 50566
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
IEC 61000 series5
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national

National versions in the same scope

AS/NZS 61000-4-3probably the same standard; matched by number only

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+1 national

National versions in the same scope

AS/NZS 61000-4-6probably the same standard; matched by number only

IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
CISPR4
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 11national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement

Certificate says EN 55024. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national

National versions in the same scope

AS/NZS CISPR 32identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

IEC4
IEC 62232
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)

Certificate says EN 62311. Probably the same standard; not checked against the EN document.

IEC 62369-1
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 62209 series3
IEC 62209-1
IEC 62209-2
IEC 62209-3
Other standards4
ANSI C63.26
FCC PART 15Radio Frequency Devices
IEEE Std 1528:2013
RSS-130

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

6821.01

The scope document we hold says it is valid until 2027-01-31.

View scope

Accredited scope, certificate 6821.01

LineMethodMatrixRange
1IEEE/ANSI C95.1; IEEE Std 1528; IEEE Std 1528:2013; IEEE C95.3; FCC KDB 865664 D01; FCC KDB 447498; FCC KDB 616217 D04; FCC KDB 941225 D01, D05, D05A, D06, and D07; RSS-102 (Issue 6); RSS-102.SAR.MEAS; SPR-004; IEC/EN IEC/BS EN IEC/IS IEC 62311; IEC/EN/BS EN /IS IEC 62479; IEC/EN/BS EN IS IEC 62209-1; IEC/EN/BS EN IS IEC 62209-2; BS EN IEC/IEEE 62209-1528; EN IEC/IEEE 62209-1528; IEC/IEEE 62209-1528; ICNIRP Guidelines; IEC/EN IEC/BS EN IEC/IS IEC 62209-3; IEC/EN/BS EN 62232; IEC/IEEE 63195-1; EN IEC/IEEE 63195-1; BS EN IEC/IEEE 63195-1; IEC TR 63170; IEC PAS 63184; IEC/EN/BS EN 62369-1; EN/BS EN 50364; EN/BS EN 50360; EN/BS EN 50566; EN/BS EN 50663; EN/BS EN 50665; EN/BS EN 50385; Radiocommunications Equipment (General) Rules AS/NZS 2772; ARPANSA Radiation Protection Series S-1--
2CFR 47, FCC Part 15 B (using ANSI C63.4:2014); CFR 47, FCC Part 18 (using FCC OST/MP-:1986); CISPR 11; BS EN/EN 55011; AS/NZS CISPR 11; CISPR 32; BS EN/EN 55032; AS/NZS CISPR 32; IEC/EN 61000-6-3; IEC/EN 61000-6-4; ICES-001 ICES-003; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-52; IEC/EN/BS EN 61000-4-3; AS/NZS 61000-4-3; BS /EN IEC 61000-6-1; EN 55035; BS EN 55035; CISPR 35; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-52; CISPR 24; EN/BS EN 55024; IEC/ EN / BS EN 61000-4-6; AS/NZS 61000-4-6; IEC 61000-6-1; EN IEC 61000-6-1; EN/BS EN 55035; CISPR 35; CISPR 24; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-19; FCC CFR 47, FCC Part 15 Subpart C (using ANSI C63.10, ANSI C63.10-2020); CFR 47, FCC Part 15 Subpart E (using ANSI C63.10, ANSI C63.10-2020); FCC Part 15 Subpart E with DFS (using KDB 905462 D02 (v02)); KDB 905462 D02 (v02)); CFR 47 FCC Part 22 (using ANSI/TIA-603-E; ANSI C63.26-2015); CFR 47 FCC Part 24 (using ANSI/TIA-603-E; ANSI C63.26-2015); CFR 47 FCC Part 27 (using ANSI/TIA-603-E; ANSI C63.26-2015); CFR 47 FCC Part 90 (using ANSI C63.26-2015); CFR 47 FCC Part 96 (using ANSI C63.26-2015)-to 40 GHz
3Canada RSS-GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-140; RSS-192; RSS-195; RSS-197; RSS-198; RSS-199; RSS-210 (< 40 GHz); RSS-216 (< 40 GHz); RSS-247; RSS-248; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 300 440; ETSI EN 302 502; ETSI EN 303 687; ETSI EN 301 511; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI EN 301 908-13; ITU-R SM 329-12; ETSI EN 303 413; ETSI EN 303 417; 3GPP TS 51.010-1; ETSI TS 151 010-1; 3GPP TS 34.121-1; ETSI TS 134 121-1; 3GPP TS 36.521-1; ETSI TS 136 521-1; 3GPP TS 38.101-1; ETSI TS 138 101-1; 3GPP TS 38.101-3; ETSI TS 138 101-3; 3GPP TS 38.521-1; ETSI TS 138 521-1; 3GPP TS 38.521-3; ETSI TS 138 521-3; CTIA Certification Test Plan for Wireless Device Over-the-Air Performance3; CTIA Certification Test Plan for RF Performance Evaluation of Wi-Fi Mobile Converged Devices3; CTIA Certification Test Plan for Wireless Device Over-the-Air Performance CTIA-01.03-Normative-Reporting-Tables3; CTIA Certification Test Plan for Wireless Device Over-the-Air Performance CTIA-01.04-Informative-Reporting-Tables3; CTIA Certification Test Plan for Wireless Device Over-the-Air Performance CTIA-01.20-Test-Methodology-SISO-Anechoic-Chamber3; CTIA Certification Test Plan for Wireless Device Over-the-Air Performance CTIA 01.50 Wireless Technology, 3GPPRadio Access Technologies3; CTIA Certification Test Plan for Wireless Device Over-the-Air Performance CTIA 01.52 Wireless Technology, Non-3GPP Radio Access Technologies3; CTIA Certification Test Plan for Wireless Device Over-the-Air Performance CTIA 01.73 Supporting Procedures3-to 40 GHz
4ETSI EN 301 908-2; ETSI EN 301 908-13; ETSI TS 137 144; ETSI TS 137 544; 3GPP TS 34.114; 3GPP TR 25.914; 3GPP TS 25.144; 3GPP TS 37.544; 3GPP TS 37.144; 3GPP TR 37.902; 3GPP TR 38.834; 3GPP TS 38.161; ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10-2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI C63.26-2015-to 40000 MHz
5ANSI C63.26-2015; IEEE Std 1528:2013-to 40000 MHz
6

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited GUANGDONG OPPO MOBILE TELECOMMUNICATIONS CO., LTD. TECH. TEST CENTER Guangdong, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 27th day of January 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6821.01 Valid to January 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.