United States

FLORIDA METROLOGY

Port St. Lucie, FL, United States

Visit website
A2LA 3864.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
7
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 7 scope lines.

A2LA certificate 3864.01 · 7 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 635 mm
2-Height Gages; Gage blocks & surface plate; Micrometers; Calipers; Length Indicators; Bore Gages; Ring gages; Surface Plates; Rulers & Tape Measures; Radius Gages; Angle Gages
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3864.01) Revised 3/11/2026 Page 2 of 6 Parameter/Equipment Range CMC2, 5 (±) Comments Height Gages3 Up to 36 in (36 to 60) in (89 + 2.6L) µin (190 + 9.6L) µin Gage blocks & surface plate Micrometers3 – Outside Inside (0.05 to 6) in (6 to 36) in Up to 4 in (44 + 3.3L) µin (68 + 6.3L) µin (44 + 3.3L) µin Gage blocks, grade 0 Gage blocks, grade 0, with accessory kit Calipers3 Up to 36 in (200 + 11L) µin Gage blocks, grade 0 Length Indicators3 – Dial, Digital, & Electronic (0.05 to 6) in (62 + 2.5L) µin Gage blocks, grade 0 Bore Gages3 Up to 0.31 in (0.31 to 0.5) in (0.5 to 1.0) in (1.0 to 2.0) in (2.0 to 3.0) in (3.0 to 5.0) in 21 µin 32 µin 34 µin 40 µin 30 µin 75 µin Ring gages Surface Plates – Grades AA, A, & B3 Repeatability Flatness 0.002 in Up to 144 in, diagonal length 52 µin (74 + 0.3L) µin Repeat-o-meter Planekator Rulers & Tape Measures3 Up to 100 ft (72 + 14L) + 0.6R µin Gage blocks, grade 0 Radius Gages Up to 0.75 in 140 µin Video measuring device Angle Gages Up to 180° 0.01° Video measuring device
See scope document
3-thermocouple
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3864.01) Revised 3/11/2026 Page 3 of 6 II. Dimensional Testing7 Parameter/Equipment Range CMC2, 5 (±) Comments Linear Accuracy – Measure X, Y Linearity Z Linearity Angle Up to 200 mm Up to 160 mm (0 to 90)° (3.7 + 0.002L) µm (5.4 + 0.0012L) µm 0.16° Video measuring device Video measuring device & angle blocks III. Electrical/DC Low Frequency Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Temperature Indicators - Thermocouple Simulation 3 Type J Type K Type N Type R Type S Type T (-210 to -100) °C (-100 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to 400) °C (400 to 1200) °C (1200 to 1372) °C (-200 to --100) °C (-100 to 900) °C (900 to 1300) °C (-20 to 0) °C (0 to 100) °C (100 to 1767) °C (0 to 200) °C (200 to 1400) °C (1400 to 1767) °C (-200 to 0) °C (0 to 400) °C 0.54 °C 0.76 °C 0.52 °C 0.62 °C 0.54 °C 0.76 °C 0.58 °C 0.81 °C 0.76 °C 0.58 °C 1.4 °C 1.3 °C 1.2 °C 1.4 °C 1.2 °C 1.3 °C 0.68 °C 0.76 °C Fluke 744
See scope document
4ASTM Class 1; ASTM Class 4; ASTM Class 6--
5-Rockwell Hardness Testers; Freezers, Ovens, Incubators, Furnaces; Dry block temperature calibrator; Fluke 744 w TC probe, PRT
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3864.01) Revised 3/11/2026 Page 5 of 6 Parameter/Equipment Range CMC2 (±) Comments Indirect Verification of Rockwell Hardness Testers 3 HRC (20 to 30) HRC (35 to 55) HRC (60 to 65) HRC HRBW (40 to 59) HRBW (60 to 79) HRBW (80 to 100) HRBW HR15TW (60 to 79) HR15TW (80 to 89) HR15TW (90 to 99) HR15TW HR30N (41 to 56) HR30N (57 to 72) HR30N (73 to 84) HR30N 1.3 HRC 1.3 HRC 0.68 HRC 1.9 HRBW 1.2 HRBW 1.3 HRBW 1.8 HR15TW 1.3 HR15TW 1.2 HR15TW 1.3 HR30N 1.3 HR30N 0.96 HR30N Master blocks V. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Temperature3 – Measure Freezers, Ovens, Incubators, Furnaces (30 to 200) °C (200 to 375) °C (-50 to 275) °C (275 to 450) °C (450 to 600) °C (600 to 1000) °C 0.32 °C 0.59 °C 1.5 °C 2.2 °C 2.9 °C 4.7 °C Dry block temperature calibrator Fluke 744 w TC probe, PRT _________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
See scope document
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3864.01) Revised 3/11/2026 Page 6 of 6 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 Applicable to digital controllers only. 5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in its respective units, R is the numerical value of the resolution of the device in its respective units. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This test is not equivalent to that of a calibration. 8 This scope meets A2LA’s P112 Flexible Scope Policy. 9 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
7ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.