Registers refreshed 2026-11-20.See refresh dates
United States

Trescal

3905 West Eau Gallie,, Suite 105, 32934, Melbourne, FL, United States

Visit website
A2LA 7598.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
41
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 41 scope lines.

A2LA certificate 7598.01 · 41 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006-See scope document
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 2 of 40 Parameter/Equipment Range CMC2, 5 (±) Comments Electrolytic Conductivity – Measuring Equipment3 10 µS/cm 100 µS/cm 1000 µS/cm 10 000 µS/cm 0.35 µS/cm 1.4 µS/cm 12 µS/cm 110 µS/cm Conductivity solutions III. Dimensional Parameter/Equipment Range CMC 2, 5, 6 (±) Comments Angle – Measuring Equipment3 Up to 60 ° 30 °, 45 °, 60 °, 90 ° 5.4 arc-sec 0.0061 ° Gage blocks, sine bar Angle blocks Precision Levels Bubble Levels, Inclinometers, Digital Protractors Up to ± 1000 arc-sec Base Length: 3 in 6 in 9 in 12 in 15 in 1.1 arc-sec 0.58 arc-sec 0.39 arc-sec 0.29 arc-sec 0.2 arc-sec Gage blocks, surface plate Flatness – Measure3 Up to 4 in diameter 3.2 µin Optical flats Parallelism – Measure3 Up to 4 in diameter 6.3 µin Optical flats Length Standards, Foils, Shims & Feeler/Thickness Gauges 3 Up to 13 in 5.2 µin + 1.7 µin/in Trimos HC5 ULM Tri-Bore Gages3 Up to 6 in 58 µin + 19 µin/in Master ring gages Bore Gages3 Up to 13 in 29 µin + 2.1 µin/in Master gage blocks & ULM Trimos HC5
to 60 °
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 3 of 40 Parameter/Equipment Range CMC2, 4, 5, 6 (±) Comments Hand Tools3 – Calipers Outside Step, Depth Inside Digital & Dial Indicators Micrometers Spindle Linearity Height Gages Depth Gages Chamfer Gage – Inside & Outside Diameter Up to 80 in Up to 80 in Up to 8 in Up to 1 in (1 to 6) in Up to 80 in Up to 80 in Up to 80 in Up to 2 in 30 µin + 5.9 µin/in 32 µin + 4.9 µin/in 58 µin + 19 µin/in 31 µin 31 µin + 3.1 µin/in 7.9 µin + 5 µin/in 58 µin + 4.4 µin/in 32 µin + 5.9 µin/in 32 µin + 4.6 µin/in Gage blocks Master ring Optimahr 25 Gage blocks Gage blocks Gage blocks Gage blocks Master rings & plug gages Coating Thickness – Measuring Equipment 3 Non-Ferrous Ferrous (11 to 5600) µm (0.1 to 4.5) in 0.58 µm + 0.001 µm/µm 48 µin + 1.1 µin/in Thickness foil sets Step block Optical Comparators3 – Linear Axis Magnification Angularity/Rotational Accuracy X & Y up to 24 in 10x, 20x, 50x, 30x, 31.25x, 50x, 62.5x, 100x, 250x, 500x (0 to 360) ° 110 µin + 10 µin/in 0.014 % 1.4 arc-sec Glass masters, angle blocks, precision square Plain Diameter3 – Internal (Plain Rings) (1 to 4) in 3.2 µin + 2.2 µin/in Trimos HC5 ULM gage blocks
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 4 of 40 Parameter/Equipment Range CMC2, 4, 5, 6 (±) Comments Plain Diameter3 – External (Plug Gages, Pin Gages) Up to 13 in 6.6 µin + 2 µin/in Trimos HC5 ULM Surface Plate3 – Flatness Local Area Flatness Up to 16 ft diagonal Up to 0.001 in √D x 12 µin/in 31 µin Electronic leveling system Repeat-o-meter Threaded Plug Gages3 – Pitch Diameter (Imperial) Pitch Diameter (Metric) Up to 12 in, (2.5 to 80) TPI Up to 300 mm, (0.2 to 10) mm pitch 75 µin + 1.1 µin/in 1.9 µm + 1.1 µm/m Gage blocks, thread wires & Trimos HC5 ULM Adjustable Thread Rings3 Up to 12 in Class X Setting Plug Master setting plugs Gage Amplifier & Probe Up to 0.05 in 17 µin/in Gage blocks Profilometers3 (12 to 120) Ra µin 3.7 Ra µin Roughness reference Spheres & Precision Balls Diameter & Sphericity Up to 3 in 5.2 µin + 1.5 µin/in Trimos HC5 ULM Microscopes Up to 1 in (25 mm) MAG: Up to 1000X 240 µin Stage micrometers
to 16 ft
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 5 of 40 Parameter/Equipment Range CMC2, 4, 5, 6 (±) Comments Crimp Tools, Safety Cable Tools, Banding Tools Break Force Hole Size3 Safety Cable Strength Banding Strength Up to 100 lbf Up to 0.5 in Up to 110 lbf (2 to 200) lbf 0.14 lbf 130 µin 4.7 % 1.2 lbf Mark-10 ESM301 base w/ M5-100 Pins w/ micrometer DMC SCT-TB1 w/ torque wrench DMC 15-DFTI w/ DBS-CG4D cal fixture IV. Electrical – DC/Low Frequency Parameter/Equipment Range CMC 2, 6, 7 (±) Comments DC Voltage – Generate3 (0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 0.4 µV + 7.5 µV/V 0.71 µV + 5 µV/V 2.6 µV + 3.5 µV/V 4.1 µV + 3.5 µV/V 41 µV + 5 µV/V 0.41 mV + 6.5 µV/V Fluke 5730A DC Voltage – Generate3 (0 to 120) mV (0 to 1.2) V (0 to 12) V (0 to 120) V (0 to 1020) V 0.8 µV + 9.3 µV/V 1.9 µV + 5.8 µV/V 10 µV + 6.2 µV/V 0.1 mV + 8.5 µV/V 1 mV + 8.5 µV/V Fluke 5560A DC Voltage – Measure3 (0 to 1) mV (1 to 10) mV 25 nV + 52 µV/V 0.41 µV + 53 µV/V Agilent 34420A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 6 of 40 Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments DC Voltage – Measure3 (7 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 0.33 µV + 12 µV/V 0.52 µV + 3.1 µV/V 1.6 µV + 2.6 µV/V 35 µV + 5 µV/V 1.2 mV + 6 µV/V Agilent 3458A Opt 002 CMC’s apply to 120 % of range, except 1000 V range maximum is 1050 V DC High Voltage3 – Measure (1 to 10) kV (10 to 100) kV 0.036 % 0.063 % Vitrek 4700 w/ HVL-100 DC Current – Generate3 Generate Clamp Meters (20 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (2.2 to 11) A (0 to 120) µA (0 to 1.2) mA (0 to 12) mA (0 to 120) mA (0 to 1.2) A (0 to 3.1) A (0 to 12) A (0 to 30.2) A Up to 15 A (10 to 100) A (100 to 300) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A 6 nA + 40 µA/A 11 nA + 33 µA/A 67 nA + 34 µA/A 0.93 µA + 50 µA/A 12 µA + 0.13 mA/A 0.49 mA + 0.36 mA/A 6 nA + 97 µA/A 15 nA + 78 µA/A 82 nA + 78 µA/A 0.82 µA + 78 µA/A 10 µA + 0.12 mA/A 0.15 mA + 0.23 mA/A 0.25 mA + 0.23 mA/A 0.5 mA + 0.78 mA/A 0.0024 % 0.0044 % 0.0023 % 50 mA + 6.5 mA/A 0.18 A + 3.4 mA/A 0.83 A + 3.3 mA/A Fluke 5730A w/ 5725A Fluke 5560A Agilent 3458A w/ shunts Fluke 5520A w/ 5500A/coil DC Current3 – Measure (1 to 100) nA (0.1 to 1) µA (1 to 10) µA (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 41 pA + 89 µA/A 70 pA + 18 µA/A 0.4 nA + 19 µA/A 0.82 nA + 17 µA/A 5.8 nA + 19 µA/A 53 nA + 16 µA/A 0.53 µA + 32 µA/A 10 µA + 110 µA/A Agilent 3458A Opt 002 CMC’s apply to 120 % of range, except 1 A range maximum is 1.05 A
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 7 of 40 Parameter/Equipment Range CMC2, 6, 7 (±) Comments DC Resistance3 – Generate, Fixed Points 1 mΩ 10 mΩ 100 mΩ 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 1 MΩ 0.034 µΩ 0.31 µΩ 3 µΩ 30 µΩ 290 µΩ 2.9 mΩ 29 mΩ 290 mΩ 6.2 Ω L&N resistors DC Resistance – Measure3 (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ (0.01 to 1) Ω (1 to 10) Ω 55 µΩ + 15 µΩ/Ω 0.52 mΩ + 11 µΩ/Ω 0.53 mΩ + 8.5 µΩ/Ω 5.3 mΩ + 8.3 µΩ/Ω 53 mΩ + 8.5 µΩ/Ω 2.3 Ω + 14 µΩ/Ω 0.1 kΩ + 55 µΩ/Ω 1 kΩ + 0.52 mΩ/Ω 10 kΩ + 5.1 mΩ/Ω 3.2 µΩ + 71 µΩ/Ω 86 µΩ + 60 µΩ/Ω Agilent 3458A Opt 002 CMC’s apply to 120 % of range Agilent 34420A Resistance3 – Generate Up to 10.99 Ω (11 to 32.999) Ω (33 to 109.9999) Ω (110 to 329.999) Ω 330 Ω to 1.099 999 kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ 330 k Ω to 1.099 99 MΩ (1.1 to 3.299 99) MΩ (3.3 to 10.9999) MΩ (11 to 32.9999) MΩ (33 to 109.9999) MΩ (110 to 329.999) MΩ (330 to 1100) MΩ (0 to 12) Ω (12 to 120) Ω 120 Ω to 1.2 kΩ (1.2 to 12) kΩ (12 to 120) kΩ 120 kΩ to 1.2 MΩ 1.1 mΩ + 23 µΩ/Ω 1.4 mΩ + 23 µΩ/Ω 1.8 mΩ + 22 µΩ/Ω 3.9 mΩ + 22 µΩ/Ω 8.8 mΩ + 22 µΩ/Ω 40 mΩ + 22 µΩ/Ω 89 mΩ + 22 µΩ/Ω 0.4 Ω + 22 µΩ/Ω 0.87 Ω + 22 µΩ/Ω 8.2 Ω + 25 µΩ/Ω 14 Ω + 25 µΩ/Ω 90 Ω + 47 µΩ/Ω 0.39 kΩ + 0.1 mΩ/Ω 4.2 kΩ + 0.19 mΩ/Ω 15 kΩ + 0.39 mΩ/Ω 0.34 MΩ + 2.3 mΩ/Ω 4.2 MΩ + 12 mΩ/Ω 1 mΩ + 19 µΩ/Ω 1.2 mΩ + 19 µΩ/Ω 4.4 mΩ + 19 µΩ/Ω 44 mΩ + 19 µΩ/Ω 0.44 Ω + 19 µΩ/Ω 4.4 Ω + 19 µΩ/Ω Fluke 5520A Fluke 5560A
to 1100 MΩ
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 8 of 40 Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments Resistance3 – Generate (cont) (1.2 to 12) MΩ (12 to 120) MΩ (120 to 1200) MΩ 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 63 Ω + 27 µΩ/Ω 6.5 kΩ + 0.33 mΩ/Ω 0.47 MΩ + 3.1 mΩ/Ω 41 µΩ 95 µΩ 180 µΩ 230 µΩ 440 µΩ 1 mΩ 1.9 mΩ 6.5 mΩ 12 mΩ 65 mΩ 120 mΩ 850 mΩ 16 Ω 13 Ω 34 Ω 400 Ω 900 Ω 50 kΩ Fluke 5560A Fluke 5730A DC Resistance3 – Generate, Fixed Points, High Voltage < 20 V Up to 1000 V (1 to 5) kV (1 to 10) kV 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 10 TΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 10 TΩ 0.0013 % 0.0013 % 0.0013 % 0.0022 % 0.004 % 0.012 % 0.062 % 0.24 % 0.36 % 0.51 % 1.5 % 0.54 % 0.5 % 0.5 % 0.5 % 0.51 % 0.51 % 2.8 % IET VRS-100-11- 1K-BP
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 9 of 40 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Voltage – Generate3 (1 to 12) mV (12 to 120) mV (0.12 to 1.2) V (1.2 to 12) V (12 to 120) V (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40.01 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40.01 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40.01 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz* 0.11 mV + 50 mV/V 8.9 µV + 1.9 mV/V 7.7 µV + 0.68 mV/V 6.1 µV + 0.12 mV/V 6.3 µV + 0.29 mV/V 16 µV + 1.2 mV/V 36 µV + 6.2 mV/V 36 µV + 6.2 mV/V 1.2 mV + 50 mV/V 30 µV + 1.9 mV/V 15 µV + 0.68 mV/V 7.4 µV + 0.11 mV/V 11 µV + 0.27 mV/V 28 µV + 0.62 mV/V 49 µV + 1.6 mV/V 49 µV + 1.6 mV/V 12 mV + 50 mV/V 0.3 mV + 1.9 mV/V 0.15 mV + 0.68 mV/V 74 µV + 0.11 mV/V 21 µV + 0.11 mV/V 42 µV + 0.23 mV/V 0.11 mV + 0.54 mV/V 0.26 mV + 1.5 mV/V 0.26 mV + 1.5 mV/V 0.12 V + 50 mV/V 3 mV + 1.9 mV/V 1.6 mV + 0.68 mV/V 0.49 mV + 0.11 mV/V 0.18 mV + 0.11 mV/V 0.33 mV + 0.23 mV/V 0.77 mV + 0.54 mV/V 2.5 mV + 1.6 mV/V 2.5 mV + 1.6 mV/V 1.2 V + 50 mV/V 30 mV + 1.9 mV/V 16 mV + 0.68 mV/V 4.8 mV + 0.11 mV/V 1.8 mV + 0.11 mV/V 3.3 mV + 0.23 mV/V 7.7 mV + 0.54 mV/V 39 mV + 1.6 mV/V Fluke 5560A * Max output 70 V
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 10 of 40 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Voltage – Generate3 (cont) (120 to 330) V (330 to 1020) V (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 10 kHz 0.3 V + 1.9 mV/V 0.16 V + 0.68 mV/V 21 mV + 0.11 mV/V 36 mV + 0.23 mV/V 0.16 V + 1.2 mV/V 0.7 V + 1.9 mV/V 0.3 V + 0.68 mV/V 0.12 V + 0.11 mV/V Fluke 5560A AC Voltage – Generate3 Up to 2.2 mV (2.2 to 22) mV (22 to 220) mV 220 mV to 2.2 V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 4 µV + 0.24 mV/V 4 µV + 90 µV/V 4 µV + 80 µV/V 4 µV + 0.2 mV/V 5 µV + 0.5 mV/V 10 µV + 1.1 mV/V 20 µV + 1.4 mV/V 20 µV + 2.7 mV/V 4.6 µV + 0.24 mV/V 4.2 µV + 90 µV/V 4.2 µV + 80 µV/V 4.5 µV + 0.2 mV/V 6.2 µV + 0.5 mV/V 12 µV + 1.1 mV/V 23 µV + 1.4 mV/V 26 µV + 2.7 mV/V 18 µV + 0.24 mV/V 9.2 µV + 90 µV/V 8.4 µV + 57 µV/V 10 µV + 0.12 mV/V 24 µV + 0.31 mV/V 36 µV + 0.66 mV/V 58 µV + 1.4 mV/V 0.11 mV + 2.7 mV/V 96 µV + 0.25 mV/V 37 µV + 91 µV/V 18 µV + 42 µV/V 26 µV + 68 µV/V 50 µV + 85 µV/V 0.16 mV + 0.35 mV/V 0.43 mV + 1 mV/V 0.69 mV + 1.7 mV/V Fluke 5730A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 11 of 40 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Voltage – Generate3 (cont) (2.2 to 22) V (22 to 220) V* (220 to 1100) V (220 to 750) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (15 to 50) Hz** 50 Hz to 1 kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz (30 to 50) kHz (50 to 100) kHz 0.97 mV + 0.25 mV/V 0.36 mV + 92 µV/V 0.16 mV + 42 µV/V 0.26 mV + 68 µV/V 0.4 mV + 84 µV/V 1.2 mV + 0.27 mV/V 4.3 mV + 1 mV/V 6.6 mV + 1.5 mV/V 9.6 mV + 0.25 mV/V 3.6 mV + 92 µV/V 1.8 mV + 52 µV/V 2.9 mV + 81 µV/V 5.9 mV + 0.15 mV/V 36 mV + 0.91 mV/V 0.14 V + 4.4 mV/V 0.26 V + 8 mV/V 84 mV + 0.31 mV/V 20 mV + 69 µV/V 25 mV + 90 µV/V 43 mV + 0.17 mV/V 0.14 V + 0.17 mV/V 0.15 V + 0.6 mV/V 0.55 V + 2.3 mV/V Fluke 5730A * 220 V range subject to 2.2E7 V-Hz limitation w/5725A ** Maximum output limited to 250 V AC Voltage – Generate Up to 1.1 mV (1.1 to 3.3) mV 10 Hz to 119.99 kHz 120 kHz to 2 MHz (2 to 11.9) MHz (12 to 20) MHz (20 to 30) MHz 10 Hz to 119.99 kHz 120 kHz to 2 MHz (2 to 11.9) MHz (12 to 20) MHz (20 to 30) MHz 2 µV + 8 mV/V 2 µV + 8.6 mV/V 4 µV + 7.6 mV/V 4 µV + 10 mV/V 17 µV + 19 mV/V 11 µV + 7.8 mV/V 12 µV + 7 mV/V 13 µV + 7.8 mV/V 15 µV + 9.1 mV/V 25 µV + 19 mV/V Fluke 5730A wideband option 03 (high frequency flatness)
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 12 of 40 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Voltage – Generate (cont) (3.3 to 11) mV (11 to 33) mV (33 to 110) mV (110 to 330) mV (0.33 to 1.1) V (1.1 to 3.5) V 10 Hz to 119.99 kHz 120 kHz to 2 MHz (2 to 11.9) MHz (12 to 20) MHz (20 to 30) MHz 10 Hz to 119.99 kHz 120 kHz to 1.1999 MHz (2 to 11.9) MHz (2 to 11.9) MHz (12 to 20) MHz (20 to 30) MHz 10 Hz to 119.99 kHz 120 kHz to 1.1999 MHz (2 to 11.9) MHz (2 to 11.9) MHz (12 to 20) MHz (20 to 30) MHz 10 Hz to 119.99 kHz 120 kHz to 1.1999 MHz (2 to 11.9) MHz (2 to 11.9) MHz (12 to 20) MHz (20 to 30) MHz 10 Hz to 119.99 kHz 120 kHz to 1.1999 MHz (2 to 11.9) MHz (2 to 11.9) MHz (12 to 20) MHz (20 to 30) MHz 10 Hz to 119.99 kHz 120 kHz to 1.1999 MHz (2 to 11.9) MHz (2 to 11.9) MHz (12 to 20) MHz (20 to 30) MHz 33 µV + 7.8 mV/V 32 µV + 7.1 mV/V 33 µV + 7.4 mV/V 36 µV + 8.4 mV/V 52 µV + 14 mV/V 91 µV + 6.9 mV/V 84 µV + 6.1 mV/V 87 µV + 6 mV/V 87 µV + 6.4 mV/V 98 µV + 7.6 mV/V 0.15 mV + 13 mV/V 0.26 mV + 6.9 mV/V 0.24 mV + 6.1 mV/V 0.25 mV + 6 mV/V 0.25 mV + 6.4 mV/V 0.28 mV + 7.6 mV/V 0.45 mV + 13 mV/V 0.75 mV + 6.1 mV/V 0.66 mV + 5.1 mV/V 0.7 mV + 5 mV/V 0.7 mV + 5.5 mV/V 0.83 mV + 6.8 mV/V 1.4 mV + 13 mV/V 2.4 mV + 6.1 mV/V 4.4 mV + 4.2 mV/V 4.7 mV + 3.7 mV/V 4.7 mV + 4.8 mV/V 5.4 mV + 6.5 mV/V 7.6 mV + 13 mV/V 6.2 mV + 5.3 mV/V 6.8 mV + 4 mV/V 7.8 mV + 3.6 mV/V 7.8 mV + 4.5 mV/V 9.9 mV + 6.1 mV/V 17 mV + 12 mV/V Fluke 5730A wideband option 03 (high frequency flatness)
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 13 of 40 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Voltage – Measure (0.1 to 10) mV (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 750) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 3.3 µV + 0.3 mV/V 1.3 µV + 0.2 mV/V 1.4 µV + 0.3 mV/V 2.1 µV + 1 mV/V 6.1 µV + 5 mV/V 42 µV + 40 mV/V 4.7 µV + 70 µV/V 2.7 µV + 70 µV/V 3.4 µV + 0.14 mV/V 5 µV + 0.3 mV/V 10 µV + 0.8 mV/V 40 µV + 3 mV/V 0.11 mV + 10 mV/V 0.16 mV + 15 mV/V 47 µV + 70 µV/V 27 µV + 70 µV/V 35 µV + 0.14 mV/V 50 µV + 0.3 mV/V 0.1 mV + 0.8 mV/V 0.4 mV + 3 mV/V 1.1 mV + 10 mV/V 1.6 mV + 15 mV/V 0.47 mV + 70 µV/V 0.27 mV + 70 µV/V 0.34 mV + 0.14 mV/V 0.5 mV + 0.3 mV/V 1 mV + 0.8 mV/V 4 mV + 3 mV/V 11 mV + 10 mV/V 16 mV + 15 mV/V 6 mV + 0.2 mV/V 4 mV + 0.2 mV/V 4 mV + 0.2 mV/V 5.5 mV + 0.35 mV/V 14 mV + 1.2 mV/V 50 mV + 4 mV/V 0.16 V + 15 mV/V 56 mV + 0.4 mV/V 42 mV + 0.4 mV/V 56 mV + 0.6 mV/V 98 mV + 1.2 mV/V 0.22 V + 3 mV/V Agilent 3458A CMC’s apply to 120% of range, except 1000 V range maximum is 700 V
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 14 of 40 Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments AC High Voltage3 Measure (1 to 10) kV (10 to 70) kV 50/60 Hz 50/60 Hz 0.14 % 0.12 % Vitrek 4700 w/ HVL-100 AC Current3 – Generate (9 to 220) µA (29 to 330) µA (0.22 to 2.2) mA (0.33 to 3.3) mA (2.2 to 22) mA (3.3 to 33) mA (22 to 220) mA (33 to 330) mA (0.22 to 2.2) A (2.2 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 20 nA + 0.25 mA/A 13 nA + 0.16 mA/A 11 nA + 98 µA/A 16 nA + 0.28 mA/A 77 nA + 1.1 mA/A 0.67 nA + 12 mA/A 0.1 µA + 0.25 mA/A 79 nA + 0.16 mA/A 68 nA + 99 µA/A 0.16 µA + 0.2 mA/A 0.89 µA + 1.1 mA/A 3.3 µA + 7.7 mA/A 1 µA + 0.25 µA/A 0.76 µA + 0.16 µA/A 0.65 µA + 0.1 mA/A 1 µA + 0.2 µA/A 7.4 µA + 1.1 m A/A 13 µA + 3.1 mA/A 9.5 µA + 0.25 mA/A 7.1 µA + 0.16 mA/A 4.8 µA + 0.1 mA/A 8 µA + 0.2 mA/A 34 µA + 1.1 mA/A 0.26 mA + 3.1 mA/A 90 µA + 0.24 mA/A 0.18 mA + 0.45 mA/A 1.7 mA + 7 mA/A 1.2 mA + 0.46 mA/A 2.5 mA + 0.95 mA/A 8.7 mA + 3.6 mA/A 14 mA + 0.9 mA/A 17 mA + 1.2 mA/A 0.26 A + 23 mA/A Fluke 5730A Fluke 5520A Fluke 5730A Fluke 5520A Fluke 5730A Fluke 5520A Fluke 5730A Fluke 5520A Fluke 5730A Fluke 5730A w/ 5725A Fluke 5520A
15--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 15 of 40 Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments AC Current3 – Generate (cont) Clamp Meters3: Toroidal: (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A Non-Toroidal: (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 26 mA + 2.1 mA/A 50 mA + 1.9 mA/A 0.34 A + 1.9 mA/A 60 mA + 6 mA/A 0.11 A + 5.3 mA/A 0.86 A + 5.3 mA/A 60 mA + 3.8 mA/A 0.23 A + 3.7 mA/A 1.2 A + 3.7 mA/A 90 mA + 7.2 mA/A 0.28 A + 6.7 mA/A 1.6 A + 6.7 mA/A Fluke 5520A, 5500A/coil AC Current – Generate3 (12 to 120) µA (0.12 to 1.2) mA (1.2 to 12) mA (12 to 120) mA (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 12 nA + 0.19 mA/A 12 nA + 0.19 mA/A 12 nA + 0.19 mA/A 52 nA + 1.2 mA/A 1 µA + 3.9 mA/A 0.13 µA + 0.19 mA/A 0.13 µA + 0.19 mA/A 0.13 µA + 0.19 mA/A 0.25 µA + 1.2 mA/A 5.5 µA + 3.9 mA/A 1.3 µA + 0.19 mA/A 1.3 µA + 0.19 mA/A 1.3 µA + 0.19 mA/A 2.5 µA + 1.2 mA/A 15 µA + 3.9 mA/A 13 µA + 0.19 mA/A 6.5 µA + 0.12 mA/A 10 µA + 0.19 mA/A 25 µA + 1.2 mA/A 0.15 mA + 3.9 mA/A Fluke 5560A
10 to 1025 A
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 16 of 40 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Current – Generate3 (cont) (0.12 to 1.2) A (1.2 to 3.1) A (3.1 to 12) A (12 to 30.2) A (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz 0.13 mA + 0.18 mA/A 75 µA + 0.19 mA/A 0.1 mA + 0.19 mA/A 0.53 mA + 1.9 mA/A 0.77 mA + 3.9 mA/A 0.85 mA + 0.29 mA/A 0.58 mA + 0.23 mA/A 0.65 mA + 0.29 mA/A 2.8 mA + 1.9 mA/A 1.9 mA + 0.29 mA/A 1.2 mA + 0.23 mA/A 1.7 mA + 0.29 mA/A 6.9 mA + 1.9 mA/A 19 mA + 0.78 mA/A 15 mA + 0.54 mA/A 55 mA + 3.9 mA/A Fluke 5560A AC Current3 – Measure (5 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz 55 nA + 4 mA/A 43 nA + 1.5 mA/A 38 nA + 0.64 mA/A 0.41 µA + 4.1 mA/A 0.28 µA + 1.6 mA/A 0.24 µA + 0.67 mA/A 0.22 µA + 0.37 mA/A 0.24 µA + 0.67 mA/A 0.61 µA + 4.1 mA/A 1.8 µA + 5.6 mA/A 2.2 µA + 4.1 mA/A 2.1 µA + 1.6 mA/A 2 µA + 0.67 mA/A 2 µA + 0.37 mA/A 2 µA + 0.67 mA/A 4.2 µA + 4.1 mA/A 15 µA + 5.6 mA/A Agilent 3458A CMC’s apply to 120 % of range, except 1 A range maximum is 1.05 A
17--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 17 of 40 Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments AC Current3 – Measure (cont) (10 to 100) mA (0.1 to 1) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz 40 µA + 4.1 mA/A 27 µA + 1.5 mA/A 23 µA + 0.6 mA/A 21 µA + 0.3 mA/A 23 µA + 0.6 mA/A 60 µA + 4 mA/A 0.18 mA + 5.5 mA/A 0.4 mA + 4.1 mA/A 0.28 mA + 1.7 mA/A 0.24 mA + 0.9 mA/A 0.25 mA + 1.1 mA/A 0.35 mA + 3.1 mA/A 0.9 mA + 10 mA/A Agilent 3458A CMC’s apply to 120 % of range, except 1 A range maximum is 1.05 A AC Resistance3 – Generate, Fixed Points DC to 13 MHz See matrix below. Interpolate CMC’s for frequencies between stated cardinal points. HP 16074A 0 Ω 0.1 Ω 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ DC 6.6 % 0.0061 % 0.0023 % 0.00087 % 0.00061 % 0.00087 % 100 Hz 0.0037 % 0.0035 % 0.0021 % 0.00035 % 1 kHz 0.0035 % 10 kHz 0.0035 % 100 kHz 0.0035 % 1 MHz 0.0037 % 0.0023 % 0.0011 % 2 MHz 0.0053 % 0.0045 % 0.004 % 3 MHz 0.0096 % 0.0097 % 0.0092 % 0.009 % 5 MHz 0.025 % 10 MHz 0.1 % 13 MHz 0.17 %
10 to 100 mA
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 18 of 40 Parameter/Range Frequency CMC2, 6, 7 (±) Comments Capacitance3 – Generate (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (0.33 to 10.999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.99) nF (0.33 to 1.0999) µF (1.1 to 3.2999) µF (3.3 to 10.999) µF (11 to 32.999) µF (33 to 109.99) µF (110 to 329.99) µF (0.33 to 1.0999) mF (1.1 to 3.2999) mF (3.3 to 10.999) mF (11 to 32.999) mF (33 to 110) mF 200 pF to 1.2 nF (1.2 to 12) nF (> 3 to 12) nF (12 to 120) nF (> 30 to 120) nF (0.12 to 1.2) µF (1.2 to 12) µF (12 to 120) µF (0.12 to 1.2) mF (1.2 to 12) mF (12 to 120) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz (10 to 1000) Hz (10 to 1000) Hz (10 to 1000) Hz (10 to 1000) Hz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz Up to 50 Hz Up to 20 Hz Up to 6 Hz Up to 2 Hz Up to 0.6 Hz Up to 0.2 Hz 100 Hz to 10 kHz 150 Hz to 5 kHz (10 to 150) Hz 200 Hz to 1.3 kHz (10 to 200) Hz (2 to 310) Hz (0.5 to 110) Hz (0.5 to 40) Hz (0.1 to 11) Hz (0.03 to 4) Hz (0.01 to 1.3) Hz 8.5 pF + 3.8 pF/nF 9.4 pF + 3.9 pF/nF 12 pF + 3.9 pF/nF 15 pF + 1.9 pF/nF 99 pF + 1.9 pF/nF 0.14 nF + 1.9 pF/nF 0.45 nF + 1.9 pF/nF 1.4 nF + 1.9 nF/µF 4.5 nF + 1.9 nF/µF 14 nF + 1.9 nF/µF 58 nF + 3.1 nF/µF 0.19 µF + 3.5 nF/µF 0.62 µF + 3.5 nF/µF 1.9 µF + 3.5 µF/mF 6.8 µF + 3.4 µF/mF 38 µF + 2.4 µF/mF 87 µF + 5.8 µF/mF 0.36 mF + 8.5 µF/mF 2.4 pF + 0.86 mF/F 6.2 pF + 0.9 mF/F 7.8 pF + 0.9 mF/F 43 pF + 1 mF/F 61 pF + 1 mF/F 0.42 nF + 1 mF/F 4.2 nF + 1 mF/F 40 nF + 1.2 mF/F 0.48 µF + 1.9 mF/F 5.3 µF + 1.9 mF/F 77 µF + 3.9 mF/F Fluke 5520A Fluke 5560A DC Power3 – Generate Up to 330 µA Up to 3.3 mA Up to 33 mA Up to 330 mA Up to 1.1 A Up to 3 A Up to 11 A Up to 20.5 A Up to 1020 V Up to 337 mW (0.337 to 3.366) W (3.366 to 33.66) W (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.91) kW 0.017 % 0.021 % 0.0093 % 0.0093 % 0.019 % 0.043 % 0.044 % 0.13 % Fluke 5520A
19--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 19 of 40 Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments DC Power3 – Generate (cont) Up to 120 µA Up to 1.2 mA Up to 12 mA Up to 120 mA Up to 1.2 A Up to 3.1 A Up to 12 A Up to 30.2 A Up to 122 mW (0.12 to 1.224) W (1.225 to 12.24) W (12.24 to 122.4) W (0.1224 to 1.224) kW (1.224 to 3.162) kW (3.162 to 12.24) kW (12.24 to 30.8) kW 0.015 % 0.0092 % 0.0087 % 0.0087 % 0.013 % 0.028 % 0.025 % 0.08 % Fluke 5560A Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Power3 – Generate See Table Below See Table Below Fluke 5520A (45 to 65) Hz (3.366 to 33.66) W (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.9) kW Ø 0 ° PF=1.000 0.052 % 0.068 % 0.076 % 0.083 % 0.17 % Ø 10 ° PF=0.985 0.06 % 0.075 % 0.082 % 0.088 % 0.18 % Ø 20 ° PF=0.940 0.082 % 0.093 % 0.099 % 0.1 % 0.18 % Ø 30 ° PF=0.866 0.11 % 0.12 % 0.13 % 0.2 % Ø 40 ° PF=0.766 0.16 % 0.17 % 0.23 % Ø 50 ° PF=0.643 0.21 % 0.22 % 0.27 % Ø 60 ° PF=0.500 0.31 % 0.35 % Ø 70 ° PF=0.342 0.48 % 0.49 % 0.51 % Ø 80 ° PF=0.174 0.99 % 1 %
to 12 A
20

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 20 of 40 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Power3 – Generate (cont) See Table Below See Table Below Fluke 5520A (65 to 500) Hz (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.9) kW Ø 0 ° PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 % Ø 10 ° PF=0.985 0.094 % 0.1 % 0.11 % 0.14 % 0.22 % Ø 20 ° PF=0.940 0.17 % 0.18 % 0.2 % 0.26 % Ø 30 ° PF=0.866 0.26 % 0.28 % 0.33 % Ø 40 ° PF=0.766 0.37 % 0.39 % 0.42 % Ø 50 ° PF=0.643 0.53 % 0.56 % Ø 60 ° PF=0.500 0.76 % 0.77 % 0.78 % Ø 70 ° PF=0.342 1.2 % Ø 80 ° PF=0.174 2.5 % 500 Hz to 1 kHz (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.9) kW Ø 0 ° PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 % (45 to 65) Hz (1.22 to 12.2) W (12.2 to 122) W (0.122 to 1.22) kW (1.22 to 3.16) kW (3.16 to 12.2) kW (12.2 to 30.8) kW Ø 0 ° PF=1.000 0.038 % 0.029 % 0.034 % 0.048 % 0.04 % 0.11 % Ø 10 ° PF=0.985 0.049 % 0.042 % 0.046 % 0.057 % 0.051 % 0.11 % Ø 20 ° PF=0.940 0.074 % 0.07 % 0.072 % 0.079 % 0.075 % 0.12 % Ø 30 ° PF=0.866 0.11 % 0.15 % Ø 40 ° PF=0.766 0.15 % Ø 50 ° PF=0.643 0.21 % Ø 60 ° PF=0.500 0.3 % Ø 70 ° PF=0.342 0.48 % Ø 80 ° PF=0.174 0.99 %
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 21 of 40 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Power – Generate3 (cont) See Table Below See Table Below Fluke 5560A (65 to 500) Hz (12.2 to 122) W (0.122 to 1.22) kW (1.22 to 3.16) kW (3.16 to 12.2) kW (12.2 to 30.8) kW Ø 0 ° PF=1.000 0.029 % 0.034 % 0.048 % 0.04 % 0.11 % Ø 10 ° PF=0.985 0.068 % 0.071 % 0.078 % 0.074 % 0.12 % Ø 20 ° PF=0.940 0.14 % 0.17 % Ø 30 ° PF=0.866 0.2 % 0.21 % 0.23 % Ø 40 ° PF=0.766 0.29 % 0.3 % 0.31 % Ø 50 ° PF=0.643 0.42 % Ø 60 ° PF=0.500 0.61 % Ø 70 ° PF=0.342 0.96 % Ø 80 ° PF=0.174 2 % 500 Hz to 1 kHz (12.2 to 122) W (0.122 to 1.22) kW (1.22 to 3.16) kW (3.16 to 12.2) kW (12.2 to 30.8) kW Ø 0 ° PF=1.000 0.029 % 0.034 % 0.048 % 0.04 % 0.11 % Ø 10 ° PF=0.985 0.13 % 0.16 % Ø 20 ° PF=0.940 0.26% 0.28 % Ø 30 ° PF=0.866 0.41% 0.42 % Ø 40 ° PF=0.766 0.59 % 0.6 % Ø 50 ° PF=0.643 0.83 % Ø 60 ° PF=0.500 1.2 % Ø 70 ° PF=0.342 1.9 % Ø 80 ° PF=0.174 4 % Ø 0 ° PF=1.000 0.071 % 0.082 % Ø 10 ° PF=0.985 0.64 %
22

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 22 of 40 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Power – Generate3 (cont) See Table Below See Table Below Fluke 5560A (1 to 5) kHz (6 to 60) W (60 to 600) W (0.6 to 1.55) kW Ø 20 ° PF=0.940 1.3 % Ø 30 ° PF=0.866 2 % Ø 40 ° PF=0.766 2.8 % Ø 50 ° PF=0.643 4 % (5 to 10) kHz (3 to 30) W (30 to 300) W Ø 0 ° PF=1.000 0.28 % 0.34 % Ø 10 ° PF=0.985 1.4 % Ø 20 ° PF=0.940 2.7 % Ø 30 ° PF=0.866 4.2 % (10 to 30) kHz (3 to 300) W Ø 0 ° PF=1.000 1.1 % Ø 10 ° PF=0.985 3.4 % Ø 20 ° PF=0.940 5.9 % Phase Shift – Generate (PF=1) (10 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz Ø 0.1 ° Ø 0.26 ° Ø 0.51 ° Ø 2.6 ° Ø 5.1 ° Ø 10 ° Ø 0.1 ° Ø 0.2 ° Ø 0.4 ° Ø 1.9 ° Ø 3.9 ° Ø 7.8 ° Fluke 5520A Fluke 5560A
23

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 23 of 40 Parameter/Range Frequency CMC2, 6, 7 (±) Comments Capacitance – Generate, Fixed Points3 1 pF 10 pF 100 pF 1000 pF 10 nF 100 nF 1 µF 1 kHz 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 1 kHz 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 1 kHz 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 1 kHz 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 120 Hz to 100 kHz 120 Hz to 200 kHz 120 Hz > 120 Hz to 10 kHz (> 10 to 100) kHz 0.000 05 pF 0.000 09 pF 0.000 23 pF 0.000 41 pF 0.000 63 pF 0.0009 pF 0.0025 pF 0.0037 pF 0.0001 pF 0.000 41 pF 0.000 42 pF 0.0004 pF 0.0005 pF 0.0006 pF 0.0012 pF 0.0016 pF 0.001 pF 0.004 pF 0.005 pF 0.0067 pF 0.009 pF 0.013 pF 0.033 pF 0.049 pF 0.043 pF 0.065 pF 0.15 pF 0.28 pF 0.44 pF 0.62 pF 1.9 pF 2.8 pF 0.51 pF 5.1 pF 65 pF 57 pF 81 pF Agilent 16380A capacitance set Agilent 16380C capacitance set
24

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 24 of 40 Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments Capacitance3 – Generate 1 nF 10 nF 100 nF 1 µF Up to 100 kHz Up to 100 kHz Up to 100 kHz Up to 100 kHz 71 fF 1.8 pF 41 pF 71 pF GenRad 1409-F GenRad 1409-L GenRad 1409-T GenRad 1409-Y Capacitance – Measure3 See Table Below See Table Below (interpolate CMC’s for frequencies between cardinal points stated below). Quadtech 7600 Plus 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 2 MHz Up to 10 pF 23 % (10 to 100) pF 2.8 % 21 % (100 to 1000) pF 1.7 % 0.079 % 0.057 % 0.081 % 0.075 % 0.66 % (1 to 10) nF 13 % 0.21 % 0.062 % 0.055 % 0.081 % 0.08 % 0.79 % (10 to 100) nF 1.5 % 0.15 % 0.06 % 0.055 % 0.087 % 0.13 % 2.2 % (0.1 to 1) µF 0.99 % 0.14 % 0.061 % 0.058 % 0.14 % 0.63 % 16 % (1 to 10) µF 0.94 % 0.14 % 0.064 % 0.085 % 0.71 % 5.6 % (10 to 100) µF 0.95 % 0.15 % 0.097 % 0.36 % 6.4 % (0.1 to 1) mF 1.1 % 0.28 % 0.43 % 3.1 % (1 to 10) mF 2.1 % 1.5 % 3.8 % AC Impedance – Measure3 See Table Below See Table Below (interpolate CMC’s for frequencies between cardinal points stated below). Quadtech 7600 Plus 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 2 MHz (10 to 100) mΩ 19 % 7.7 % 3.4 % 5.5 % 21 % (0.1 to 1) Ω 2.7 % 1.1 % 0.55 % 0.86 % 3.1 % 4.9 % (1 to 10) Ω 1.1 % 0.48 % 0.26 % 0.4 % 1.3 % 2 % (10 to 100) Ω 0.95 % 0.41 % 0.23 % 0.35 % 1.1 % 1.8 % (0.1 to 1) kΩ 0.94 % 0.41 % 0.23 % 0.35 % 1.1 % 1.7 % (1 to 10) kΩ 0.97 % 0.42 % 0.23 % 0.36 % 4.7 % 7.1 % (10 to 100) kΩ 1.3 % 0.55 % 0.29 % 0.45 % 6.1 % 9.4 % (0.1 to 1) MΩ 9.1 % 3.7 % 1.7 % 2.7 % 21 %
25--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 25 of 40 Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments Inductance – Measure3 See Table Below See Table Below (interpolate CMC’s for frequencies between cardinal points stated below). Quadtech 7600 Plus 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 2 MHz Up to 100 nH 6.7 % (0.1 to 1) µH 8.5 % 4.3 % 2.2 % (1 to 10) µH 5.3 % 1.2 % 1.4 % 1.8 % (10 to 100) µH 12 % 0.74 % 0.43 % 1.2 % 1.7 % (0.1 to 1) mH 1.6 % 0.28 % 0.36 % 1.1 % 3.5 % (1 to 10) mH 3.8 % 0.52 % 0.23 % 0.35 % 2.3 % 8.5 % (10 to 100) mH 1.2 % 0.42 % 0.23 % 0.36 % 5.5 % 23 % (0.1 to 1) H 0.97 % 0.41 % 0.23 % 0.41 % 15 % (1 to 10) H 0.94 % 0.41 % 0.27 % 2 % (10 to 100) H 0.96 % 0.5 % 1.3 % Inductance – Generate3 (13 to 120) µH (0.120 01 to 1.2) mH (1.2001 to 3.3) mH (3.3 to 12) mH (490 to 550) Hz (550 to 999) Hz 1 kHz (1.001 to 13) kHz (13 to 17) kHz (260 to 330) Hz (330 to 999) Hz 1 kHz (1.001 to 1.6) kHz (1.6 to 2.5) kHz (0.5 to 999) Hz 110 Hz (111 to 800) Hz (800 to 980) Hz (0.5 to 109) Hz 110 Hz (111 to 1000) Hz (1 to 1.4) kHz 1.5 % 0.67 % 0.38 % 0.67 % 1.5 % 1.4 % 0.49 % 0.2 % 0.49 % 1.4 % 0.74 % 0.46 % 0.74 % 1.6 % 0.49 % 0.2 % 0.49 % 1.4 % Fluke 5560A
to 100 H
26

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 26 of 40 Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments Inductance – Generate3 (cont) (12 to 83) mH (83 to 120) mH (0.120 01 to 0.65) H (0.65 to 1.2) H (1.2001 to 5.5) H (5.5 to 12) H (12.001 to 30) H (30 to 120) H (0.1 to 99) Hz 100 Hz (101 to 180) Hz (180 to 230) Hz (0.1 to 99) Hz 100 Hz (101 to 320) Hz (320 to 1000) Hz (0.05 to 9.9) Hz 10 Hz (10.1 to 30) Hz (30 to 50) Hz (0.05 to 9.9) Hz 10 Hz (10.1 to 100) Hz (100 to 170) Hz (0.01 to 2.99) Hz 3 Hz (3.01 to 8) Hz (8 to 16) Hz (0.01 to 2.99) Hz 3 Hz (3.01 to 19) Hz (19 to 37) Hz (0.005 to 1.99) Hz 2 Hz (2.01 to 4) Hz (4 to 16) Hz (0.005 to 1.99) Hz 2 Hz (2.01 to 7) Hz (7 to 14) Hz 0.53 % 0.25 % 0.53 % 1.4 % 0.49 % 0.2 % 0.49 % 1.4 % 0.61 % 0.32 % 0.6 % 1.5 % 0.52 % 0.24 % 0.52 % 1.4 % 0.68 % 0.4 % 0.68 % 1.6 % 0.57 % 0.28 % 0.57 % 1.4 % 0.89 % 0.61 % 0.89 % 1.8 % 0.61 % 0.32 % 0.6 % 1.5 % Fluke 5560A Inductance3 – Generate 100 mH 1 H 10 H 100 Hz to 1 kHz 100 Hz to 1 kHz 100 Hz to 1 kHz 48 µH 0.59 mH 4.2 mH General radio 1482L 1482P 1482T
27--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 27 of 40 Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments Distortion3 – Measure (-101 to 0) dB (-130 to 0) dB 20 Hz to 20 kHz (20 to 100) kHz 100 kHz to 3 GHz (3 to 6.5) GHz (6.5 to 22) GHz (22 to 26.5) GHz 1.2 dB 2.3 dB 0.54 dB 1.8 dB 2.4 dB 3 dB Agilent 8903B Agilent E4440A Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments Oscilloscopes3 – Volt DC Signal Into 50 Ω DC Signal Into 1 MΩ Squarewave Into 50 Ω Squarewave Into 1 MΩ Edge Into 50 Ω Leveled Sine Wave Time Marker ± (0 to 6.6) V ± (0 to 130) V 1 mV to 6 V p-p 1 mV to 130 Vp-p 10 Hz to 1 kHz (1 to 100) kHz (200 to 300) ps, 100 kHz to 2 MHz (200 to 350) ps, (2 to 10) MHz 5 mV to 5.5 V 50 kHz (reference) 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 4 mV to 3.5 V (600 to 1100) MHz 5 s to 50 ms 50 ms to 1 ns 33 µV + 2 mV/V 33 µV + 0.39 mV/V 91 µV + 4.3 mV/V 0.2 mV + 0.8 mV/V 0.24 mV + 2 mV/V 82 ps 82 ps 0.33 mV + 17 mV/V 0.4 mV + 31 mV/V 0.43 mV + 36 mV/V 0.53 mV + 57 mV/V 0.58 mV + 67 mV/V 0.0021 % + (t / 1000) % 0.000 36 % Fluke 5560A/SC1100 t = time in seconds
-101 to 0 dB
28

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 28 of 40 Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments Oscilloscopes3 – (cont) Wave Generator 1.8 mV to 2.8 V p-p (50 Ω), 10 Hz to 100 kHz 1.8 mV to 55 V p-p (1 MΩ), 10 Hz to 100 kHz 0.12 mV + 23 mV/V 0.12 mV + 23 mV/V Fluke 5560A/SC1100 Oscilloscopes3 – Voltage DC Into 1 MΩ DC Into 50 Ω Squarewave Into 1 MΩ Squarewave Into 50 Ω Risetime – Generate Time Marker Level Sine Wave ± 1 mV to 200 V ± 1 mV to 5 V 40 µV + 200 V p-p 40 µV to 5 Vp-p 150 ps 10 Hz to 2 MHz 9 ns to 83 µs 83 µs to 55 s 50 kHz to 300 MHz (300 to 550) MHz (0.55 to 1.1) GHz (1.1 to 3.2) GHz 28 µV + 0.25 mV/V 29 µV + 0.25 mV/V 12 µV + 1 mV/V 12 µV + 1 mV/V 28 ps 0.000 047 % 0.000 35 % 3.3 % 3.4 % 4 % 4.4 % Fluke 9500B w/9530 active head Fluke 9500B Fluke 9500B w/ active heads Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments AC Flatness – Measure 10 Hz 100 Hz to 1 MHz 3 MHz 8 MHz 10 MHz 20 MHz 30 MHz 50 MHz 0.053 % 0.05 % 0.052 % 0.057 % 0.064 % 0.11 % 0.18 % 0.3 % Thermal voltage converter, 3458A CMC’s can be interpolated for frequencies that fall between cardinal points.
29

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 29 of 40 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTDs3 – Measure Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω Ni 120, 120 Ω (-200 to 80) °C (-80 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 800) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-80 to 260) °C 0.019 °C 0.023 °C 0.027 °C 0.031 °C 0.038 °C 0.048 °C 0.018 °C 0.018 °C 0.02 °C 0.024 °C 0.029 °C 0.038 °C 0.017 °C 0.018 °C 0.019 °C 0.019 °C 0.025 °C 0.03 °C 0.036 °C 0.043 °C 0.054 °C 0.057 °C 0.061 °C 0.061 °C 0.071 °C 0.073 °C 0.09 °C 0.029 °C 0.029 °C 0.036 °C 0.041 °C 0.049 °C 0.02 °C 0.02 °C 0.027 °C 0.03 °C 0.038 °C 0.0097 °C Fluke 7526A
30

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 30 of 40 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTDs3 – Measure (cont) Cu 427, 10 Ω YSI 400 (-100 to 260) °C (15 to 50) °C 0.11 °C 0.0071 °C Fluke 7526A Electrical Calibration of RTDs3 – Generate PT 385, 100 Ω PT 3926, 100 Ω PT 3916, 100 Ω PT 385, 200 Ω PT 385, 500 Ω PT 385, 1000 Ω Ni 120, 120 Ω Cu 427, 10 Ω YSI 400 (-200 to 800) °C (-200 to 630) °C (-200 to 630) °C (-200 to 400) °C (400 to 630) °C (-200 to 630) °C (-200 to 630) °C (-80 to 260) °C (-100 to 260) °C (15 to 50) °C 0.052 °C 0.052 °C 0.052 °C 0.4 °C 0.5 °C 0.17 °C 0.091 °C 0.021 °C 0.38 °C 0.009 °C Fluke 7526A Thermocouple3 – Indicating Systems & Measure Type B Type C Type E (600 to 800) °C (800 to 1550) °C (1550 to 1820) °C (0 to 1000) °C (1000 to 1800) °C (1800 to 2000) °C (2000 to 2316) °C (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 600) °C (600 to 1000) °C 0.35 °C 0.28 °C 0.23 °C 0.16 °C 0.23 °C 0.27 °C 0.36 °C 0.25 °C 0.12 °C 0.091 °C 0.082 °C 0.1 °C Fluke 7526A
31

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 31 of 40 Parameter/Equipment Range CMC2 (±) Comments Thermocouple3 – Indicating Systems & Measure (cont) Type J Type K Type L Type N Type R Type S Type T Type U (-210 to -100) °C (-100 to 800) °C (800 to 1200) °C (-250 to -200) °C (-200 to -100) °C (-100 to 500) °C (500 to 800) °C (800 to 1372) °C (-200 to -100) °C (-100 to 900) °C (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 100) °C (100 to 800) °C (800 to 1300) °C (-50 to -25) °C (-25 to 0) °C (0 to 100) °C (100 to 400) °C (400 to 600) °C (600 to 1000) °C (1000 to 1600) °C (1600 to 1767) °C (-50 to -25) °C (-25 to 0) °C (0 to 100) °C (100 to 400) °C (400 to 600) °C (600 to 1000) °C (1000 to 1600) °C (1600 to 1767) °C (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 200) °C (200 to 400) °C (-200 to 0) °C (0 to 200) °C (200 to 600) °C 0.14 °C 0.091 °C 0.11 °C 0.46 °C 0.16 °C 0.1 °C 0.1 °C 0.14 °C 0.1 °C 0.092 °C 0.73 °C 0.23 °C 0.12 °C 0.11 °C 0.1 °C 0.13 °C 0.55 °C 0.45 °C 0.39 °C 0.28 °C 0.22 °C 0.21 °C 0.2 °C 0.24 °C 0.51 °C 0.43 °C 0.38 °C 0.29 °C 0.23 °C 0.22 °C 0.22 °C 0.27 °C 0.35 °C 0.16 °C 0.14 °C 0.12 °C 0.12 °C 0.23 °C 0.1 °C 0.1 °C Fluke 7526A
32

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 32 of 40 V. Electrical – RF/Microwave Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments Power Meter3 – Power Reference @ 50 MHz Power Accuracy 1 mW 3 µW to 100 mW 0.45 % 0.29 % 432A w/ 478A, 3458A 11683A range calibrator Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments Amplitude Modulation3 – Measure (5 to 99) % Depth (5 to 20) % Depth (20 to 99) % Depth (5 to 20) % Depth (20 to 99) % Depth 100 kHz to 10 MHz 10 MHz to 3 GHz (3 to 26.5) GHz 0.86 % of depth 2.6 % of depth 0.78 % of depth 4.6 % of depth 1.7 % of depth Agilent E4440A Frequency Modulation3 – Measure Modulation rate: 20 Hz to 10 kHz Deviation: 200 Hz to 40 kHz Modulation rate: 50 Hz to 200 kHz Deviation: 250 Hz to 400 kHz 250 kHz to 10 MHz 10 MHz to 6.6 GHz (6.6 to 13.2) GHz (13.2 to 26.5) GHz 1.5 % 1.5 % 2.5 % 3.8 % Agilent E4440A
33

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 33 of 40 Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments Phase Modulation3 – Measure (0.3 to ≤ 0.7) rad > 0.7 rad (0.6 to ≤ 2.0) rad 2.0 rad (1.2 to ≤ 4.0) rad > 4.0 rad 100 kHz to 6.6 GHz (6.6 to 13.2) GHz (13.2 to 26.5) GHz 3 % 1.1 % 3 % 1.1 % 3 % 1.1 % Agilent E4440A Relative Power3 – Measure (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB (-110 to -120) dB (-120 to -130) dB 100 kHz to 26.5 GHz 0.031 dB 0.035 dB 0.039 dB 0.058 dB 0.06 dB 0.064 dB 0.077 dB 0.082 dB 0.086 dB 0.096 dB 0.1 dB 0.11 dB 0.12 dB Agilent E4440A microwave measuring receiver system Attenuation – Measure3 (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB (-110 to -120) dB (-120 to -127) dB 10 MHz to 26.5 GHz 0.039 dB 0.042 dB 0.045 dB 0.062 dB 0.064 dB 0.068 dB 0.081 dB 0.085 dB 0.089 dB 0.099 dB 0.11 dB 0.11 dB 0.13 dB Agilent E4440A microwave measuring receiver system
34

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 34 of 40 Parameter/Range Frequency CMC2, 6, 7 (±) Comments Attenuation – Generate3 (1 to 11) dB (12 to 20) dB (21 to 60) dB (61 to 80) dB 81 dB (1 to 11) dB (12 to 30) dB (31 to 81) dB DC to 12.4 GHz (12.4 to 40) GHz 0.11 dB 0.14 dB 0.15 dB 0.16 dB 0.17 dB 0.35 dB 0.41 dB 0.42 dB Keysight 84907K, 84904K Displayed Average Noise Level 3 (-165 to -50) dBm 9 kHz to 4 GHz (4 to 12.4) GHz (12.4 to 18) GHz 0.34 dB 0.65 dB 1.5 dB 50 Ω termination Absolute Power3 – Measure (+10 to +20) dBm (-60 to < +10) dBm (+10 to +20) dBm (-10 to 0) dBm (-60 to -10) dBm 50 MHz to 12 GHz (12 to 18) GHz (18 to 26.5) GHz 50 MHz to 18 GHz (18 to 26.5) GHz 9 kHz to 6 GHz 9 kHz to 2 GHz 9 kHz to 6 GHz 5.3 % 5.4 % 6 % 3.7 % 4.6 % 2.6 % 3.1 % 3.7 % N1913A power meter with: E4413A E9304A
35--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 35 of 40 Parameter/Range Frequency CMC2, 6, 7 (±) Comments Single Side-Band (SSB) Phase Noise3 – Measure Carrier: 1 MHz to 26.5 GHz At offsets: 10 Hz 100 Hz 1 kHz 10 kHz 20 kHz 100 kHz 1 MHz 10 MHz 2.7 dB 2.7 dB 2.5 dB 2.4 dB 2.4 dB 2.4 dB 2.4 dB 2.4 dB Agilent E4440A option 226 (see below) Lowest measurement range is determined by the E4440A local oscillator’s interaction with the unit under test. Values stated below are informational only & serve as a guide for typical system sensitivity performance. Actual sensitivity performance may be better than what is stated. Up to 600 MHz 601 MHz to 10.1 GHz (10.3 to 26.5) GHz 10 Hz offset -102 dBc/Hz -84 dBc/Hz -76 dBc/Hz 100 Hz offset -102 dBc/Hz -84 dBc/Hz -76 dBc/Hz 1 kHz offset -114 dBc/Hz -104 dBc/Hz -95 dBc/Hz 10 kHz offset -120 dBc/Hz -114 dBc/Hz -105 dBc/Hz 100 kHz offset -125 dBc/Hz -120 dBc/Hz -120 dBc/Hz 1 MHz offset -150 dBc/Hz -145 dBc/Hz -158 dBc/Hz 10 MHz offset -158 dBc/Hz -150 dBc/Hz -140 dBc/Hz VI. Mechanical Parameter/Equipment Range CMC2, 4, 5 (±) Comments Balances3 Up to 20 kg Matrix value x R Class 1 up to 20 kg Mass Applied Unit Under Test Resolution 0.0001 g 0.001 g 0.01 g 0.1 g 1 g 10 g Up to 200 mg 0.83 500 mg to 5 g 0.91 10 g 1.0 20 g 1.2 50 g 1.7 100 g 3.1 0.87 0.82 200 g 6.1 1.0 500 g 1.7 1 kg 3.1 0.87
to 20 kg
36EURAMET CG-18-to 25000 lbf
37

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 37 of 40 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Pressure3 – Measure & Generate Vacuum Pneumatic Hydraulic (0.1 to 1000) Torr (-30 to 30) inH 2O (-13 to 30) psig (-6 to 6) psig Up to 300 psig Up to 1000 psig (8 to 17) psia (-12 to 625) psig (625 to 1250) psig (-12 to 1250) psig (1250 to 2500) psig (-12 to 2500) psig (2500 to 5000) psig (8 to 17) psia (-14 to 83) psig (83 to 150) psig (-14 to 758) psig (758 to 1500) psig (0 to 2) inH 2O (-14 to 15) psig (0 to 25) inH2O (0 to 10) inH 2O (0 to 30) psig (0 to 100) psig (0 to 500) psig (0 to 3000) psig (10 000 to 15 000) psi 0.6 Torr + 0.15 % 0.0033 inH 2O + 0.013 % x |pressure| 0.01 psi 0.0016 psi + 0.011 % x |pressure| 0.01 % 0.012 % 0.01 % 0.063 psi 0.01 % 0.13 psi 0.01 % 0.25 psi 0.01 % 0.0019 psi + 0.000 23 psi/psi 0.019 psi 0.019 psi + 000 002 psi/psi 0.18 psi 0.18 psi + 0.000 23 psi/psi 0.0014 inH 2O 0.0095 psi 0.018 inH2O 0.032 inH 2O 0.013 psi 0.045 psi 0.24 psi 1.4 psi 18 psi Teledyne HVG-2020A Fluke 6270A w/: PM500-BG7K PM200-BG200K PM500-BG40K PM600-A2M PM600-A7M Mensor CPC8000 w/: Barometric sensor 1250 psi sensor 2500 psi sensor 5000 psi sensor Mensor CPC4000 w/: Barometric sensor 150 psi sensor 1500 psi sensor Ashcroft ATE-2 w/: AM2-1 AM2-2 HQS-1 Fluke 750P01 Fluke 750P05 Fluke 750P06 Fluke 750P07 Fluke 750P29 Additel 680-15K
38--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 38 of 40 VII. Thermodynamics Parameter/Equipment Range CMC2, 4, 5, 6, 9, 10 (±) Comments Temperature3 – Measure (-196 to 660) °C 0.017 °C + 0.000 028 x ΔTChange from -200 °C Fluke 1529 w/5609 PRT Temperature3 – Measuring Equipment -196 °C (-45 to 140) °C (50 to 660) °C 0.017 °C 0.031 °C 0.049 °C + 0.000 14 x ΔT Change from 50 °C Fluke 1529 & 5609 PRT w/: LN2 Fluke 9170 dry well Fluke 9144 dry well Infrared Temperature – Measuring Equipment 3 (-15 to -12) °C (-12 to -8) °C (-8 to -4) °C (-4 to 0) °C (0 to 120) °C (35 to 500) °C 0.51 °C 0.5 °C 0.49 °C 0.48 °C 0.6 °C + 0.0017 °C/°C 0.54 °C + ΔTChange from 35 °C x 0.0042 °C Hart 4180 Hart 4181 Emissivity = 0.95 Wavelength (8 to 14) µm Relative Humidity – Measuring Equipment (10 to 95) % RH 0.14 % RH + 0.007 %RH/%RH RH Systems CGS- 240 Dew Point – Measuring Equipment (-25 to 70) °C 0.15 °C RH Systems CGS- 240 Relative Humidity3 – Measure (10 to 90) % RH (90 to 95) % RH 1.3 % RH 2.1 % RH Vaisala MI70 w/ HMP77/HMP76
-196 to 660 °C
39NIST 960-12-See scope document
40

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 40 of 40 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches; D is the numerical value of the nominal diameter of the device measured in inches; Di is the numerical value of the nominal diagonal of the plate measured in feet; R is the numerical value of the resolution of the device in its respective units; F is the applied frequency in kHz; and percentages are percentage of reading unless otherwise indicated. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 CMC components that can be reasonably attributed to the Unit Under Test have not been utilized in the calculation of the CMC value for this measurement parameter. 7 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 8 This scope meets A2LA’s P112 Flexible Scope Policy. 9 In the statement of CMC, T = greater of 1 °F or ABS value of gage environmental temperature from 68 °F. 10 In the statement of CMC, T = greater of 4 °F or ABS value of gage environmental temperature from 68 °F.
41ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

3905 West Eau Gallie,, Suite 105, Melbourne, FL, 32934, US

28.07850, -80.60779

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.