Trescal
3905 West Eau Gallie,, Suite 105, 32934, Melbourne, FL, United States
Visit website- Scope lines
- 41
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 41 scope lines.
A2LA certificate 7598.01 · 41 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 2 of 40
Parameter/Equipment
Range
CMC2, 5 (±) Comments
Electrolytic Conductivity –
Measuring Equipment3
10 µS/cm
100 µS/cm
1000 µS/cm
10 000 µS/cm
0.35 µS/cm
1.4 µS/cm
12 µS/cm
110 µS/cm
Conductivity
solutions
III. Dimensional
Parameter/Equipment Range CMC
2, 5, 6 (±) Comments
Angle – Measuring
Equipment3
Up to 60 °
30 °, 45 °, 60 °, 90 °
5.4 arc-sec
0.0061 °
Gage blocks, sine
bar
Angle blocks
Precision Levels
Bubble Levels,
Inclinometers, Digital
Protractors
Up to ± 1000 arc-sec
Base Length:
3 in
6 in
9 in
12 in
15 in
1.1 arc-sec
0.58 arc-sec
0.39 arc-sec
0.29 arc-sec
0.2 arc-sec
Gage blocks,
surface plate
Flatness – Measure3
Up to 4 in diameter
3.2 µin
Optical flats
Parallelism – Measure3
Up to 4 in diameter
6.3 µin
Optical flats
Length Standards, Foils,
Shims & Feeler/Thickness
Gauges
3
Up to 13 in
5.2 µin + 1.7 µin/in
Trimos HC5
ULM
Tri-Bore Gages3
Up to 6 in
58 µin + 19 µin/in
Master ring gages
Bore Gages3
Up to 13 in
29 µin + 2.1 µin/in
Master gage
blocks & ULM
Trimos HC5 | to 60 ° |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 3 of 40
Parameter/Equipment
Range CMC2, 4, 5, 6 (±) Comments
Hand Tools3 –
Calipers
Outside
Step, Depth
Inside
Digital & Dial Indicators
Micrometers
Spindle Linearity
Height Gages
Depth Gages
Chamfer Gage – Inside &
Outside Diameter
Up to 80 in
Up to 80 in
Up to 8 in
Up to 1 in
(1 to 6) in
Up to 80 in
Up to 80 in
Up to 80 in
Up to 2 in
30 µin + 5.9 µin/in
32 µin + 4.9 µin/in
58 µin + 19 µin/in
31 µin
31 µin + 3.1 µin/in
7.9 µin + 5 µin/in
58 µin + 4.4 µin/in
32 µin + 5.9 µin/in
32 µin + 4.6 µin/in
Gage blocks
Master ring
Optimahr 25
Gage blocks
Gage blocks
Gage blocks
Gage blocks
Master rings &
plug gages
Coating Thickness –
Measuring Equipment
3
Non-Ferrous
Ferrous
(11 to 5600) µm
(0.1 to 4.5) in
0.58 µm + 0.001
µm/µm
48 µin + 1.1 µin/in
Thickness foil
sets
Step block
Optical Comparators3 –
Linear Axis
Magnification
Angularity/Rotational
Accuracy
X & Y up to 24 in
10x, 20x, 50x, 30x,
31.25x, 50x, 62.5x,
100x, 250x, 500x
(0 to 360) °
110 µin + 10 µin/in
0.014 %
1.4 arc-sec
Glass masters,
angle blocks,
precision square
Plain Diameter3 – Internal
(Plain Rings)
(1 to 4) in
3.2 µin + 2.2 µin/in
Trimos HC5
ULM gage blocks | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 4 of 40
Parameter/Equipment
Range CMC2, 4, 5, 6 (±) Comments
Plain Diameter3 – External
(Plug Gages, Pin Gages)
Up to 13 in
6.6 µin + 2 µin/in
Trimos HC5 ULM
Surface Plate3 –
Flatness
Local Area Flatness
Up to 16 ft diagonal
Up to 0.001 in
√D x 12 µin/in
31 µin
Electronic leveling
system
Repeat-o-meter
Threaded Plug Gages3 –
Pitch Diameter (Imperial)
Pitch Diameter (Metric)
Up to 12 in,
(2.5 to 80) TPI
Up to 300 mm,
(0.2 to 10) mm pitch
75 µin + 1.1 µin/in
1.9 µm + 1.1 µm/m
Gage blocks,
thread wires &
Trimos HC5 ULM
Adjustable Thread Rings3
Up to 12 in
Class X Setting Plug
Master setting
plugs
Gage Amplifier & Probe
Up to 0.05 in
17 µin/in
Gage blocks
Profilometers3
(12 to 120) Ra µin
3.7 Ra µin
Roughness
reference
Spheres & Precision Balls
Diameter & Sphericity
Up to 3 in
5.2 µin + 1.5 µin/in
Trimos HC5 ULM
Microscopes
Up to 1 in (25 mm)
MAG: Up to 1000X
240 µin
Stage micrometers | to 16 ft |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 5 of 40
Parameter/Equipment
Range CMC2, 4, 5, 6 (±) Comments
Crimp Tools, Safety Cable
Tools, Banding Tools
Break Force
Hole Size3
Safety Cable Strength
Banding Strength
Up to 100 lbf
Up to 0.5 in
Up to 110 lbf
(2 to 200) lbf
0.14 lbf
130 µin
4.7 %
1.2 lbf
Mark-10 ESM301
base w/ M5-100
Pins w/ micrometer
DMC SCT-TB1 w/
torque wrench
DMC 15-DFTI w/
DBS-CG4D cal
fixture
IV. Electrical – DC/Low Frequency
Parameter/Equipment Range CMC
2, 6, 7 (±) Comments
DC Voltage – Generate3
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
0.4 µV + 7.5 µV/V
0.71 µV + 5 µV/V
2.6 µV + 3.5 µV/V
4.1 µV + 3.5 µV/V
41 µV + 5 µV/V
0.41 mV + 6.5 µV/V
Fluke 5730A
DC Voltage – Generate3
(0 to 120) mV
(0 to 1.2) V
(0 to 12) V
(0 to 120) V
(0 to 1020) V
0.8 µV + 9.3 µV/V
1.9 µV + 5.8 µV/V
10 µV + 6.2 µV/V
0.1 mV + 8.5 µV/V
1 mV + 8.5 µV/V
Fluke 5560A
DC Voltage – Measure3
(0 to 1) mV
(1 to 10) mV
25 nV + 52 µV/V
0.41 µV + 53 µV/V
Agilent 34420A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 6 of 40
Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments
DC Voltage – Measure3
(7 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
0.33 µV + 12 µV/V
0.52 µV + 3.1 µV/V
1.6 µV + 2.6 µV/V
35 µV + 5 µV/V
1.2 mV + 6 µV/V
Agilent 3458A Opt
002
CMC’s apply to 120
% of range, except
1000 V range
maximum is 1050 V
DC High Voltage3 –
Measure
(1 to 10) kV
(10 to 100) kV
0.036 %
0.063 %
Vitrek 4700 w/
HVL-100
DC Current – Generate3
Generate
Clamp Meters
(20 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(0 to 120) µA
(0 to 1.2) mA
(0 to 12) mA
(0 to 120) mA
(0 to 1.2) A
(0 to 3.1) A
(0 to 12) A
(0 to 30.2) A
Up to 15 A
(10 to 100) A
(100 to 300) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
6 nA + 40 µA/A
11 nA + 33 µA/A
67 nA + 34 µA/A
0.93 µA + 50 µA/A
12 µA + 0.13 mA/A
0.49 mA + 0.36 mA/A
6 nA + 97 µA/A
15 nA + 78 µA/A
82 nA + 78 µA/A
0.82 µA + 78 µA/A
10 µA + 0.12 mA/A
0.15 mA + 0.23 mA/A
0.25 mA + 0.23 mA/A
0.5 mA + 0.78 mA/A
0.0024 %
0.0044 %
0.0023 %
50 mA + 6.5 mA/A
0.18 A + 3.4 mA/A
0.83 A + 3.3 mA/A
Fluke 5730A w/
5725A
Fluke 5560A
Agilent 3458A w/
shunts
Fluke 5520A w/
5500A/coil
DC Current3 – Measure
(1 to 100) nA
(0.1 to 1) µA
(1 to 10) µA
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
41 pA + 89 µA/A
70 pA + 18 µA/A
0.4 nA + 19 µA/A
0.82 nA + 17 µA/A
5.8 nA + 19 µA/A
53 nA + 16 µA/A
0.53 µA + 32 µA/A
10 µA + 110 µA/A
Agilent 3458A Opt
002
CMC’s apply to 120
% of range, except 1
A range maximum is
1.05 A | ||
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 7 of 40
Parameter/Equipment Range CMC2, 6, 7 (±) Comments
DC Resistance3 – Generate,
Fixed Points
1 mΩ
10 mΩ
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
1 MΩ
0.034 µΩ
0.31 µΩ
3 µΩ
30 µΩ
290 µΩ
2.9 mΩ
29 mΩ
290 mΩ
6.2 Ω
L&N resistors
DC Resistance – Measure3
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
(0.01 to 1) Ω
(1 to 10) Ω
55 µΩ + 15 µΩ/Ω
0.52 mΩ + 11 µΩ/Ω
0.53 mΩ + 8.5 µΩ/Ω
5.3 mΩ + 8.3 µΩ/Ω
53 mΩ + 8.5 µΩ/Ω
2.3 Ω + 14 µΩ/Ω
0.1 kΩ + 55 µΩ/Ω
1 kΩ + 0.52 mΩ/Ω
10 kΩ + 5.1 mΩ/Ω
3.2 µΩ + 71 µΩ/Ω
86 µΩ + 60 µΩ/Ω
Agilent 3458A
Opt 002
CMC’s apply to
120 % of range
Agilent 34420A
Resistance3 – Generate
Up to 10.99 Ω
(11 to 32.999) Ω
(33 to 109.9999) Ω
(110 to 329.999) Ω
330 Ω to 1.099 999 kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
330 k Ω to 1.099 99 MΩ
(1.1 to 3.299 99) MΩ
(3.3 to 10.9999) MΩ
(11 to 32.9999) MΩ
(33 to 109.9999) MΩ
(110 to 329.999) MΩ
(330 to 1100) MΩ
(0 to 12) Ω
(12 to 120) Ω
120 Ω to 1.2 kΩ
(1.2 to 12) kΩ
(12 to 120) kΩ
120 kΩ to 1.2 MΩ
1.1 mΩ + 23 µΩ/Ω
1.4 mΩ + 23 µΩ/Ω
1.8 mΩ + 22 µΩ/Ω
3.9 mΩ + 22 µΩ/Ω
8.8 mΩ + 22 µΩ/Ω
40 mΩ + 22 µΩ/Ω
89 mΩ + 22 µΩ/Ω
0.4 Ω + 22 µΩ/Ω
0.87 Ω + 22 µΩ/Ω
8.2 Ω + 25 µΩ/Ω
14 Ω + 25 µΩ/Ω
90 Ω + 47 µΩ/Ω
0.39 kΩ + 0.1 mΩ/Ω
4.2 kΩ + 0.19 mΩ/Ω
15 kΩ + 0.39 mΩ/Ω
0.34 MΩ + 2.3 mΩ/Ω
4.2 MΩ + 12 mΩ/Ω
1 mΩ + 19 µΩ/Ω
1.2 mΩ + 19 µΩ/Ω
4.4 mΩ + 19 µΩ/Ω
44 mΩ + 19 µΩ/Ω
0.44 Ω + 19 µΩ/Ω
4.4 Ω + 19 µΩ/Ω
Fluke 5520A
Fluke 5560A | to 1100 MΩ |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 8 of 40
Parameter/Equipment
Range CMC2, 4, 6, 7 (±) Comments
Resistance3 – Generate
(cont)
(1.2 to 12) MΩ
(12 to 120) MΩ
(120 to 1200) MΩ
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
63 Ω + 27 µΩ/Ω
6.5 kΩ + 0.33 mΩ/Ω
0.47 MΩ + 3.1 mΩ/Ω
41 µΩ
95 µΩ
180 µΩ
230 µΩ
440 µΩ
1 mΩ
1.9 mΩ
6.5 mΩ
12 mΩ
65 mΩ
120 mΩ
850 mΩ
16 Ω
13 Ω
34 Ω
400 Ω
900 Ω
50 kΩ
Fluke 5560A
Fluke 5730A
DC Resistance3 –
Generate, Fixed
Points, High Voltage
< 20 V
Up to 1000 V
(1 to 5) kV
(1 to 10) kV
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
10 TΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
10 TΩ
0.0013 %
0.0013 %
0.0013 %
0.0022 %
0.004 %
0.012 %
0.062 %
0.24 %
0.36 %
0.51 %
1.5 %
0.54 %
0.5 %
0.5 %
0.5 %
0.51 %
0.51 %
2.8 %
IET VRS-100-11-
1K-BP | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 9 of 40
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
AC Voltage – Generate3
(1 to 12) mV
(12 to 120) mV
(0.12 to 1.2) V
(1.2 to 12) V
(12 to 120) V
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40.01 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40.01 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40.01 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz*
0.11 mV + 50 mV/V
8.9 µV + 1.9 mV/V
7.7 µV + 0.68 mV/V
6.1 µV + 0.12 mV/V
6.3 µV + 0.29 mV/V
16 µV + 1.2 mV/V
36 µV + 6.2 mV/V
36 µV + 6.2 mV/V
1.2 mV + 50 mV/V
30 µV + 1.9 mV/V
15 µV + 0.68 mV/V
7.4 µV + 0.11 mV/V
11 µV + 0.27 mV/V
28 µV + 0.62 mV/V
49 µV + 1.6 mV/V
49 µV + 1.6 mV/V
12 mV + 50 mV/V
0.3 mV + 1.9 mV/V
0.15 mV + 0.68 mV/V
74 µV + 0.11 mV/V
21 µV + 0.11 mV/V
42 µV + 0.23 mV/V
0.11 mV + 0.54 mV/V
0.26 mV + 1.5 mV/V
0.26 mV + 1.5 mV/V
0.12 V + 50 mV/V
3 mV + 1.9 mV/V
1.6 mV + 0.68 mV/V
0.49 mV + 0.11 mV/V
0.18 mV + 0.11 mV/V
0.33 mV + 0.23 mV/V
0.77 mV + 0.54 mV/V
2.5 mV + 1.6 mV/V
2.5 mV + 1.6 mV/V
1.2 V + 50 mV/V
30 mV + 1.9 mV/V
16 mV + 0.68 mV/V
4.8 mV + 0.11 mV/V
1.8 mV + 0.11 mV/V
3.3 mV + 0.23 mV/V
7.7 mV + 0.54 mV/V
39 mV + 1.6 mV/V
Fluke 5560A
* Max output 70 V | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 10 of 40
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
AC Voltage – Generate3
(cont)
(120 to 330) V
(330 to 1020) V
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 10 kHz
0.3 V + 1.9 mV/V
0.16 V + 0.68 mV/V
21 mV + 0.11 mV/V
36 mV + 0.23 mV/V
0.16 V + 1.2 mV/V
0.7 V + 1.9 mV/V
0.3 V + 0.68 mV/V
0.12 V + 0.11 mV/V
Fluke 5560A
AC Voltage – Generate3
Up to 2.2 mV
(2.2 to 22) mV
(22 to 220) mV
220 mV to 2.2 V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
4 µV + 0.24 mV/V
4 µV + 90 µV/V
4 µV + 80 µV/V
4 µV + 0.2 mV/V
5 µV + 0.5 mV/V
10 µV + 1.1 mV/V
20 µV + 1.4 mV/V
20 µV + 2.7 mV/V
4.6 µV + 0.24 mV/V
4.2 µV + 90 µV/V
4.2 µV + 80 µV/V
4.5 µV + 0.2 mV/V
6.2 µV + 0.5 mV/V
12 µV + 1.1 mV/V
23 µV + 1.4 mV/V
26 µV + 2.7 mV/V
18 µV + 0.24 mV/V
9.2 µV + 90 µV/V
8.4 µV + 57 µV/V
10 µV + 0.12 mV/V
24 µV + 0.31 mV/V
36 µV + 0.66 mV/V
58 µV + 1.4 mV/V
0.11 mV + 2.7 mV/V
96 µV + 0.25 mV/V
37 µV + 91 µV/V
18 µV + 42 µV/V
26 µV + 68 µV/V
50 µV + 85 µV/V
0.16 mV + 0.35 mV/V
0.43 mV + 1 mV/V
0.69 mV + 1.7 mV/V
Fluke 5730A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 11 of 40
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
AC Voltage – Generate3
(cont)
(2.2 to 22) V
(22 to 220) V*
(220 to 1100) V
(220 to 750) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(15 to 50) Hz**
50 Hz to 1 kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
0.97 mV + 0.25 mV/V
0.36 mV + 92 µV/V
0.16 mV + 42 µV/V
0.26 mV + 68 µV/V
0.4 mV + 84 µV/V
1.2 mV + 0.27 mV/V
4.3 mV + 1 mV/V
6.6 mV + 1.5 mV/V
9.6 mV + 0.25 mV/V
3.6 mV + 92 µV/V
1.8 mV + 52 µV/V
2.9 mV + 81 µV/V
5.9 mV + 0.15 mV/V
36 mV + 0.91 mV/V
0.14 V + 4.4 mV/V
0.26 V + 8 mV/V
84 mV + 0.31 mV/V
20 mV + 69 µV/V
25 mV + 90 µV/V
43 mV + 0.17 mV/V
0.14 V + 0.17 mV/V
0.15 V + 0.6 mV/V
0.55 V + 2.3 mV/V
Fluke 5730A
* 220 V range
subject to 2.2E7
V-Hz limitation
w/5725A
** Maximum
output limited to
250 V
AC Voltage – Generate
Up to 1.1 mV
(1.1 to 3.3) mV
10 Hz to 119.99 kHz
120 kHz to 2 MHz
(2 to 11.9) MHz
(12 to 20) MHz
(20 to 30) MHz
10 Hz to 119.99 kHz
120 kHz to 2 MHz
(2 to 11.9) MHz
(12 to 20) MHz
(20 to 30) MHz
2 µV + 8 mV/V
2 µV + 8.6 mV/V
4 µV + 7.6 mV/V
4 µV + 10 mV/V
17 µV + 19 mV/V
11 µV + 7.8 mV/V
12 µV + 7 mV/V
13 µV + 7.8 mV/V
15 µV + 9.1 mV/V
25 µV + 19 mV/V
Fluke 5730A
wideband option 03
(high frequency
flatness) | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 12 of 40
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
AC Voltage – Generate
(cont)
(3.3 to 11) mV
(11 to 33) mV
(33 to 110) mV
(110 to 330) mV
(0.33 to 1.1) V
(1.1 to 3.5) V
10 Hz to 119.99 kHz
120 kHz to 2 MHz
(2 to 11.9) MHz
(12 to 20) MHz
(20 to 30) MHz
10 Hz to 119.99 kHz
120 kHz to 1.1999 MHz
(2 to 11.9) MHz
(2 to 11.9) MHz
(12 to 20) MHz
(20 to 30) MHz
10 Hz to 119.99 kHz
120 kHz to 1.1999 MHz
(2 to 11.9) MHz
(2 to 11.9) MHz
(12 to 20) MHz
(20 to 30) MHz
10 Hz to 119.99 kHz
120 kHz to 1.1999 MHz
(2 to 11.9) MHz
(2 to 11.9) MHz
(12 to 20) MHz
(20 to 30) MHz
10 Hz to 119.99 kHz
120 kHz to 1.1999 MHz
(2 to 11.9) MHz
(2 to 11.9) MHz
(12 to 20) MHz
(20 to 30) MHz
10 Hz to 119.99 kHz
120 kHz to 1.1999 MHz
(2 to 11.9) MHz
(2 to 11.9) MHz
(12 to 20) MHz
(20 to 30) MHz
33 µV + 7.8 mV/V
32 µV + 7.1 mV/V
33 µV + 7.4 mV/V
36 µV + 8.4 mV/V
52 µV + 14 mV/V
91 µV + 6.9 mV/V
84 µV + 6.1 mV/V
87 µV + 6 mV/V
87 µV + 6.4 mV/V
98 µV + 7.6 mV/V
0.15 mV + 13 mV/V
0.26 mV + 6.9 mV/V
0.24 mV + 6.1 mV/V
0.25 mV + 6 mV/V
0.25 mV + 6.4 mV/V
0.28 mV + 7.6 mV/V
0.45 mV + 13 mV/V
0.75 mV + 6.1 mV/V
0.66 mV + 5.1 mV/V
0.7 mV + 5 mV/V
0.7 mV + 5.5 mV/V
0.83 mV + 6.8 mV/V
1.4 mV + 13 mV/V
2.4 mV + 6.1 mV/V
4.4 mV + 4.2 mV/V
4.7 mV + 3.7 mV/V
4.7 mV + 4.8 mV/V
5.4 mV + 6.5 mV/V
7.6 mV + 13 mV/V
6.2 mV + 5.3 mV/V
6.8 mV + 4 mV/V
7.8 mV + 3.6 mV/V
7.8 mV + 4.5 mV/V
9.9 mV + 6.1 mV/V
17 mV + 12 mV/V
Fluke 5730A
wideband option
03 (high frequency
flatness) | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 13 of 40
Parameter/Range Frequency CMC2, 6, 7 (±) Comments
AC Voltage – Measure
(0.1 to 10) mV
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 750) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
3.3 µV + 0.3 mV/V
1.3 µV + 0.2 mV/V
1.4 µV + 0.3 mV/V
2.1 µV + 1 mV/V
6.1 µV + 5 mV/V
42 µV + 40 mV/V
4.7 µV + 70 µV/V
2.7 µV + 70 µV/V
3.4 µV + 0.14 mV/V
5 µV + 0.3 mV/V
10 µV + 0.8 mV/V
40 µV + 3 mV/V
0.11 mV + 10 mV/V
0.16 mV + 15 mV/V
47 µV + 70 µV/V
27 µV + 70 µV/V
35 µV + 0.14 mV/V
50 µV + 0.3 mV/V
0.1 mV + 0.8 mV/V
0.4 mV + 3 mV/V
1.1 mV + 10 mV/V
1.6 mV + 15 mV/V
0.47 mV + 70 µV/V
0.27 mV + 70 µV/V
0.34 mV + 0.14 mV/V
0.5 mV + 0.3 mV/V
1 mV + 0.8 mV/V
4 mV + 3 mV/V
11 mV + 10 mV/V
16 mV + 15 mV/V
6 mV + 0.2 mV/V
4 mV + 0.2 mV/V
4 mV + 0.2 mV/V
5.5 mV + 0.35 mV/V
14 mV + 1.2 mV/V
50 mV + 4 mV/V
0.16 V + 15 mV/V
56 mV + 0.4 mV/V
42 mV + 0.4 mV/V
56 mV + 0.6 mV/V
98 mV + 1.2 mV/V
0.22 V + 3 mV/V
Agilent 3458A
CMC’s apply to
120% of range,
except 1000 V
range maximum is
700 V | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 14 of 40
Parameter/Range
Frequency CMC2, 4, 6, 7 (±) Comments
AC High Voltage3
Measure
(1 to 10) kV
(10 to 70) kV
50/60 Hz
50/60 Hz
0.14 %
0.12 %
Vitrek 4700 w/
HVL-100
AC Current3 – Generate
(9 to 220) µA
(29 to 330) µA
(0.22 to 2.2) mA
(0.33 to 3.3) mA
(2.2 to 22) mA
(3.3 to 33) mA
(22 to 220) mA
(33 to 330) mA
(0.22 to 2.2) A
(2.2 to 11) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
20 nA + 0.25 mA/A
13 nA + 0.16 mA/A
11 nA + 98 µA/A
16 nA + 0.28 mA/A
77 nA + 1.1 mA/A
0.67 nA + 12 mA/A
0.1 µA + 0.25 mA/A
79 nA + 0.16 mA/A
68 nA + 99 µA/A
0.16 µA + 0.2 mA/A
0.89 µA + 1.1 mA/A
3.3 µA + 7.7 mA/A
1 µA + 0.25 µA/A
0.76 µA + 0.16 µA/A
0.65 µA + 0.1 mA/A
1 µA + 0.2 µA/A
7.4 µA + 1.1 m A/A
13 µA + 3.1 mA/A
9.5 µA + 0.25 mA/A
7.1 µA + 0.16 mA/A
4.8 µA + 0.1 mA/A
8 µA + 0.2 mA/A
34 µA + 1.1 mA/A
0.26 mA + 3.1 mA/A
90 µA + 0.24 mA/A
0.18 mA + 0.45 mA/A
1.7 mA + 7 mA/A
1.2 mA + 0.46 mA/A
2.5 mA + 0.95 mA/A
8.7 mA + 3.6 mA/A
14 mA + 0.9 mA/A
17 mA + 1.2 mA/A
0.26 A + 23 mA/A
Fluke 5730A
Fluke 5520A
Fluke 5730A
Fluke 5520A
Fluke 5730A
Fluke 5520A
Fluke 5730A
Fluke 5520A
Fluke 5730A
Fluke 5730A w/
5725A
Fluke 5520A | ||
| 15 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 15 of 40
Parameter/Range
Frequency
CMC2, 4, 6, 7 (±)
Comments
AC Current3 – Generate
(cont)
Clamp Meters3:
Toroidal:
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
Non-Toroidal:
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
26 mA + 2.1 mA/A
50 mA + 1.9 mA/A
0.34 A + 1.9 mA/A
60 mA + 6 mA/A
0.11 A + 5.3 mA/A
0.86 A + 5.3 mA/A
60 mA + 3.8 mA/A
0.23 A + 3.7 mA/A
1.2 A + 3.7 mA/A
90 mA + 7.2 mA/A
0.28 A + 6.7 mA/A
1.6 A + 6.7 mA/A
Fluke 5520A,
5500A/coil
AC Current – Generate3
(12 to 120) µA
(0.12 to 1.2) mA
(1.2 to 12) mA
(12 to 120) mA
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
12 nA + 0.19 mA/A
12 nA + 0.19 mA/A
12 nA + 0.19 mA/A
52 nA + 1.2 mA/A
1 µA + 3.9 mA/A
0.13 µA + 0.19 mA/A
0.13 µA + 0.19 mA/A
0.13 µA + 0.19 mA/A
0.25 µA + 1.2 mA/A
5.5 µA + 3.9 mA/A
1.3 µA + 0.19 mA/A
1.3 µA + 0.19 mA/A
1.3 µA + 0.19 mA/A
2.5 µA + 1.2 mA/A
15 µA + 3.9 mA/A
13 µA + 0.19 mA/A
6.5 µA + 0.12 mA/A
10 µA + 0.19 mA/A
25 µA + 1.2 mA/A
0.15 mA + 3.9 mA/A
Fluke 5560A | 10 to 1025 A |
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 16 of 40
Parameter/Range
Frequency CMC2, 6, 7 (±) Comments
AC Current – Generate3
(cont)
(0.12 to 1.2) A
(1.2 to 3.1) A
(3.1 to 12) A
(12 to 30.2) A
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
0.13 mA + 0.18 mA/A
75 µA + 0.19 mA/A
0.1 mA + 0.19 mA/A
0.53 mA + 1.9 mA/A
0.77 mA + 3.9 mA/A
0.85 mA + 0.29 mA/A
0.58 mA + 0.23 mA/A
0.65 mA + 0.29 mA/A
2.8 mA + 1.9 mA/A
1.9 mA + 0.29 mA/A
1.2 mA + 0.23 mA/A
1.7 mA + 0.29 mA/A
6.9 mA + 1.9 mA/A
19 mA + 0.78 mA/A
15 mA + 0.54 mA/A
55 mA + 3.9 mA/A
Fluke 5560A
AC Current3 – Measure
(5 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
55 nA + 4 mA/A
43 nA + 1.5 mA/A
38 nA + 0.64 mA/A
0.41 µA + 4.1 mA/A
0.28 µA + 1.6 mA/A
0.24 µA + 0.67 mA/A
0.22 µA + 0.37 mA/A
0.24 µA + 0.67 mA/A
0.61 µA + 4.1 mA/A
1.8 µA + 5.6 mA/A
2.2 µA + 4.1 mA/A
2.1 µA + 1.6 mA/A
2 µA + 0.67 mA/A
2 µA + 0.37 mA/A
2 µA + 0.67 mA/A
4.2 µA + 4.1 mA/A
15 µA + 5.6 mA/A
Agilent 3458A
CMC’s apply to
120 % of range,
except 1 A range
maximum is 1.05 A | ||
| 17 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 17 of 40
Parameter/Range
Frequency
CMC2, 4, 6, 7 (±)
Comments
AC Current3 –
Measure (cont)
(10 to 100) mA
(0.1 to 1) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
40 µA + 4.1 mA/A
27 µA + 1.5 mA/A
23 µA + 0.6 mA/A
21 µA + 0.3 mA/A
23 µA + 0.6 mA/A
60 µA + 4 mA/A
0.18 mA + 5.5 mA/A
0.4 mA + 4.1 mA/A
0.28 mA + 1.7 mA/A
0.24 mA + 0.9 mA/A
0.25 mA + 1.1 mA/A
0.35 mA + 3.1 mA/A
0.9 mA + 10 mA/A
Agilent 3458A
CMC’s apply to 120
% of range, except 1
A range maximum is
1.05 A
AC Resistance3 –
Generate, Fixed
Points
DC to 13 MHz
See matrix below.
Interpolate CMC’s for
frequencies between
stated cardinal points.
HP 16074A
0 Ω 0.1 Ω 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ
DC 6.6 % 0.0061 % 0.0023 % 0.00087 % 0.00061 % 0.00087 %
100 Hz
0.0037 %
0.0035 %
0.0021 %
0.00035 %
1 kHz 0.0035 %
10 kHz 0.0035 %
100 kHz 0.0035 %
1 MHz 0.0037 % 0.0023 % 0.0011 %
2 MHz 0.0053 % 0.0045 % 0.004 %
3 MHz 0.0096 % 0.0097 % 0.0092 % 0.009 %
5 MHz 0.025 %
10 MHz 0.1 %
13 MHz 0.17 % | 10 to 100 mA |
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 18 of 40
Parameter/Range Frequency CMC2, 6, 7 (±) Comments
Capacitance3 – Generate
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(0.33 to 10.999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.99) nF
(0.33 to 1.0999) µF
(1.1 to 3.2999) µF
(3.3 to 10.999) µF
(11 to 32.999) µF
(33 to 109.99) µF
(110 to 329.99) µF
(0.33 to 1.0999) mF
(1.1 to 3.2999) mF
(3.3 to 10.999) mF
(11 to 32.999) mF
(33 to 110) mF
200 pF to 1.2 nF
(1.2 to 12) nF
(> 3 to 12) nF
(12 to 120) nF
(> 30 to 120) nF
(0.12 to 1.2) µF
(1.2 to 12) µF
(12 to 120) µF
(0.12 to 1.2) mF
(1.2 to 12) mF
(12 to 120) mF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
Up to 50 Hz
Up to 20 Hz
Up to 6 Hz
Up to 2 Hz
Up to 0.6 Hz
Up to 0.2 Hz
100 Hz to 10 kHz
150 Hz to 5 kHz
(10 to 150) Hz
200 Hz to 1.3 kHz
(10 to 200) Hz
(2 to 310) Hz
(0.5 to 110) Hz
(0.5 to 40) Hz
(0.1 to 11) Hz
(0.03 to 4) Hz
(0.01 to 1.3) Hz
8.5 pF + 3.8 pF/nF
9.4 pF + 3.9 pF/nF
12 pF + 3.9 pF/nF
15 pF + 1.9 pF/nF
99 pF + 1.9 pF/nF
0.14 nF + 1.9 pF/nF
0.45 nF + 1.9 pF/nF
1.4 nF + 1.9 nF/µF
4.5 nF + 1.9 nF/µF
14 nF + 1.9 nF/µF
58 nF + 3.1 nF/µF
0.19 µF + 3.5 nF/µF
0.62 µF + 3.5 nF/µF
1.9 µF + 3.5 µF/mF
6.8 µF + 3.4 µF/mF
38 µF + 2.4 µF/mF
87 µF + 5.8 µF/mF
0.36 mF + 8.5 µF/mF
2.4 pF + 0.86 mF/F
6.2 pF + 0.9 mF/F
7.8 pF + 0.9 mF/F
43 pF + 1 mF/F
61 pF + 1 mF/F
0.42 nF + 1 mF/F
4.2 nF + 1 mF/F
40 nF + 1.2 mF/F
0.48 µF + 1.9 mF/F
5.3 µF + 1.9 mF/F
77 µF + 3.9 mF/F
Fluke 5520A
Fluke 5560A
DC Power3 – Generate
Up to 330 µA
Up to 3.3 mA
Up to 33 mA
Up to 330 mA
Up to 1.1 A
Up to 3 A
Up to 11 A
Up to 20.5 A
Up to 1020 V
Up to 337 mW
(0.337 to 3.366) W
(3.366 to 33.66) W
(33.66 to 336.6) W
(0.3366 to 1.122) kW
(1.122 to 3.06) kW
(3.06 to 11.22) kW
(11.22 to 20.91) kW
0.017 %
0.021 %
0.0093 %
0.0093 %
0.019 %
0.043 %
0.044 %
0.13 %
Fluke 5520A | ||
| 19 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 19 of 40
Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments
DC Power3 –
Generate (cont)
Up to 120 µA
Up to 1.2 mA
Up to 12 mA
Up to 120 mA
Up to 1.2 A
Up to 3.1 A
Up to 12 A
Up to 30.2 A
Up to 122 mW
(0.12 to 1.224) W
(1.225 to 12.24) W
(12.24 to 122.4) W
(0.1224 to 1.224) kW
(1.224 to 3.162) kW
(3.162 to 12.24) kW
(12.24 to 30.8) kW
0.015 %
0.0092 %
0.0087 %
0.0087 %
0.013 %
0.028 %
0.025 %
0.08 %
Fluke 5560A
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Power3 –
Generate See Table Below See Table Below Fluke 5520A
(45 to 65) Hz (3.366 to
33.66) W
(33.66 to
336.6) W
(0.3366 to
1.122) kW
(1.122 to
3.06) kW
(3.06 to
11.22) kW
(11.22 to 20.9)
kW
Ø 0 °
PF=1.000 0.052 % 0.068 % 0.076 % 0.083 % 0.17 %
Ø 10 °
PF=0.985 0.06 % 0.075 % 0.082 % 0.088 % 0.18 %
Ø 20 °
PF=0.940 0.082 % 0.093 % 0.099 % 0.1 % 0.18 %
Ø 30 °
PF=0.866 0.11 % 0.12 % 0.13 %
0.2 %
Ø 40 °
PF=0.766 0.16 % 0.17 % 0.23 %
Ø 50 °
PF=0.643 0.21 % 0.22 % 0.27 %
Ø 60 °
PF=0.500 0.31 % 0.35 %
Ø 70 °
PF=0.342 0.48 % 0.49 % 0.51 %
Ø 80 °
PF=0.174 0.99 % 1 % | to 12 A |
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 20 of 40
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Power3 –
Generate (cont) See Table Below See Table Below Fluke 5520A
(65 to 500) Hz (33.66 to
336.6) W
(0.3366 to
1.122) kW
(1.122 to 3.06)
kW
(3.06 to
11.22) kW
(11.22 to 20.9)
kW
Ø 0 °
PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 %
Ø 10 °
PF=0.985 0.094 % 0.1 % 0.11 % 0.14 % 0.22 %
Ø 20 °
PF=0.940 0.17 % 0.18 % 0.2 % 0.26 %
Ø 30 °
PF=0.866 0.26 % 0.28 % 0.33 %
Ø 40 °
PF=0.766 0.37 % 0.39 % 0.42 %
Ø 50 °
PF=0.643 0.53 % 0.56 %
Ø 60 °
PF=0.500 0.76 % 0.77 % 0.78 %
Ø 70 °
PF=0.342 1.2 %
Ø 80 °
PF=0.174 2.5 %
500 Hz to 1 kHz (33.66 to
336.6) W
(0.3366 to
1.122) kW
(1.122 to 3.06)
kW
(3.06 to
11.22) kW
(11.22 to 20.9)
kW
Ø 0 °
PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 %
(45 to 65) Hz (1.22 to
12.2) W
(12.2 to
122) W
(0.122 to 1.22)
kW
(1.22 to
3.16) kW
(3.16 to
12.2) kW
(12.2 to 30.8)
kW
Ø 0 °
PF=1.000 0.038 % 0.029 % 0.034 % 0.048 % 0.04 % 0.11 %
Ø 10 °
PF=0.985 0.049 % 0.042 % 0.046 % 0.057 % 0.051 % 0.11 %
Ø 20 °
PF=0.940 0.074 % 0.07 % 0.072 % 0.079 % 0.075 % 0.12 %
Ø 30 °
PF=0.866 0.11 % 0.15 %
Ø 40 °
PF=0.766 0.15 %
Ø 50 °
PF=0.643 0.21 %
Ø 60 °
PF=0.500 0.3 %
Ø 70 °
PF=0.342 0.48 %
Ø 80 °
PF=0.174 0.99 % | ||
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 21 of 40
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Power –
Generate3
(cont)
See Table Below
See Table Below
Fluke 5560A
(65 to 500) Hz (12.2 to
122) W
(0.122 to
1.22) kW (1.22 to 3.16) kW (3.16 to 12.2)
kW
(12.2 to 30.8)
kW
Ø 0 °
PF=1.000 0.029 % 0.034 % 0.048 % 0.04 % 0.11 %
Ø 10 °
PF=0.985 0.068 % 0.071 % 0.078 % 0.074 % 0.12 %
Ø 20 °
PF=0.940 0.14 % 0.17 %
Ø 30 °
PF=0.866 0.2 % 0.21 % 0.23 %
Ø 40 °
PF=0.766 0.29 % 0.3 % 0.31 %
Ø 50 °
PF=0.643 0.42 %
Ø 60 °
PF=0.500 0.61 %
Ø 70 °
PF=0.342 0.96 %
Ø 80 °
PF=0.174 2 %
500 Hz to 1 kHz (12.2 to
122) W
(0.122 to
1.22) kW (1.22 to 3.16) kW (3.16 to 12.2)
kW
(12.2 to 30.8)
kW
Ø 0 °
PF=1.000 0.029 % 0.034 % 0.048 % 0.04 % 0.11 %
Ø 10 °
PF=0.985 0.13 % 0.16 %
Ø 20 °
PF=0.940 0.26% 0.28 %
Ø 30 °
PF=0.866 0.41% 0.42 %
Ø 40 °
PF=0.766 0.59 % 0.6 %
Ø 50 °
PF=0.643 0.83 %
Ø 60 °
PF=0.500 1.2 %
Ø 70 °
PF=0.342 1.9 %
Ø 80 °
PF=0.174 4 %
Ø 0 °
PF=1.000 0.071 % 0.082 %
Ø 10 °
PF=0.985 0.64 % | ||
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 22 of 40
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Power –
Generate3
(cont)
See Table Below
See Table Below
Fluke 5560A
(1 to 5) kHz (6 to 60) W (60 to 600) W (0.6 to 1.55) kW
Ø 20 °
PF=0.940 1.3 %
Ø 30 °
PF=0.866 2 %
Ø 40 °
PF=0.766 2.8 %
Ø 50 °
PF=0.643 4 %
(5 to 10) kHz (3 to 30) W (30 to 300) W
Ø 0 °
PF=1.000 0.28 % 0.34 %
Ø 10 °
PF=0.985 1.4 %
Ø 20 °
PF=0.940 2.7 %
Ø 30 °
PF=0.866 4.2 %
(10 to 30) kHz
(3 to 300) W
Ø 0 °
PF=1.000 1.1 %
Ø 10 °
PF=0.985 3.4 %
Ø 20 °
PF=0.940 5.9 %
Phase Shift –
Generate (PF=1)
(10 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
Ø 0.1 °
Ø 0.26 °
Ø 0.51 °
Ø 2.6 °
Ø 5.1 °
Ø 10 °
Ø 0.1 °
Ø 0.2 °
Ø 0.4 °
Ø 1.9 °
Ø 3.9 °
Ø 7.8 °
Fluke 5520A
Fluke 5560A | ||
| 23 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 23 of 40
Parameter/Range Frequency CMC2, 6, 7 (±) Comments
Capacitance – Generate, Fixed
Points3
1 pF
10 pF
100 pF
1000 pF
10 nF
100 nF
1 µF
1 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
120 Hz to 100 kHz
120 Hz to 200 kHz
120 Hz
> 120 Hz to 10 kHz
(> 10 to 100) kHz
0.000 05 pF
0.000 09 pF
0.000 23 pF
0.000 41 pF
0.000 63 pF
0.0009 pF
0.0025 pF
0.0037 pF
0.0001 pF
0.000 41 pF
0.000 42 pF
0.0004 pF
0.0005 pF
0.0006 pF
0.0012 pF
0.0016 pF
0.001 pF
0.004 pF
0.005 pF
0.0067 pF
0.009 pF
0.013 pF
0.033 pF
0.049 pF
0.043 pF
0.065 pF
0.15 pF
0.28 pF
0.44 pF
0.62 pF
1.9 pF
2.8 pF
0.51 pF
5.1 pF
65 pF
57 pF
81 pF
Agilent 16380A
capacitance set
Agilent 16380C
capacitance set | ||
| 24 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 24 of 40
Parameter/Range
Frequency CMC2, 4, 6, 7 (±) Comments
Capacitance3 – Generate
1 nF
10 nF
100 nF
1 µF
Up to 100 kHz
Up to 100 kHz
Up to 100 kHz
Up to 100 kHz
71 fF
1.8 pF
41 pF
71 pF
GenRad 1409-F
GenRad 1409-L
GenRad 1409-T
GenRad 1409-Y
Capacitance – Measure3
See Table Below
See Table Below
(interpolate CMC’s for
frequencies between
cardinal points stated
below).
Quadtech 7600 Plus
10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 2 MHz
Up to 10 pF 23 %
(10 to 100) pF 2.8 % 21 %
(100 to 1000) pF 1.7 % 0.079 % 0.057 % 0.081 % 0.075 % 0.66 %
(1 to 10) nF 13 % 0.21 % 0.062 % 0.055 % 0.081 % 0.08 % 0.79 %
(10 to 100) nF 1.5 % 0.15 % 0.06 % 0.055 % 0.087 % 0.13 % 2.2 %
(0.1 to 1) µF 0.99 % 0.14 % 0.061 % 0.058 % 0.14 % 0.63 % 16 %
(1 to 10) µF 0.94 % 0.14 % 0.064 % 0.085 % 0.71 % 5.6 %
(10 to 100) µF 0.95 % 0.15 % 0.097 % 0.36 % 6.4 %
(0.1 to 1) mF 1.1 % 0.28 % 0.43 % 3.1 %
(1 to 10) mF 2.1 % 1.5 % 3.8 %
AC Impedance – Measure3
See Table Below
See Table Below
(interpolate CMC’s for
frequencies between
cardinal points stated
below).
Quadtech 7600 Plus
10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 2 MHz
(10 to 100) mΩ 19 % 7.7 % 3.4 % 5.5 % 21 %
(0.1 to 1) Ω 2.7 % 1.1 % 0.55 % 0.86 % 3.1 % 4.9 %
(1 to 10) Ω 1.1 % 0.48 % 0.26 % 0.4 % 1.3 % 2 %
(10 to 100) Ω 0.95 % 0.41 % 0.23 % 0.35 % 1.1 % 1.8 %
(0.1 to 1) kΩ 0.94 % 0.41 % 0.23 % 0.35 % 1.1 % 1.7 %
(1 to 10) kΩ 0.97 % 0.42 % 0.23 % 0.36 % 4.7 % 7.1 %
(10 to 100) kΩ 1.3 % 0.55 % 0.29 % 0.45 % 6.1 % 9.4 %
(0.1 to 1) MΩ 9.1 % 3.7 % 1.7 % 2.7 % 21 % | ||
| 25 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 25 of 40
Parameter/Range
Frequency CMC2, 4, 6, 7 (±) Comments
Inductance – Measure3
See Table Below
See Table Below
(interpolate CMC’s for
frequencies between
cardinal points stated
below).
Quadtech 7600 Plus
10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 2 MHz
Up to 100 nH 6.7 %
(0.1 to 1) µH 8.5 % 4.3 % 2.2 %
(1 to 10) µH 5.3 % 1.2 % 1.4 % 1.8 %
(10 to 100) µH 12 % 0.74 % 0.43 % 1.2 % 1.7 %
(0.1 to 1) mH 1.6 % 0.28 % 0.36 % 1.1 % 3.5 %
(1 to 10) mH 3.8 % 0.52 % 0.23 % 0.35 % 2.3 % 8.5 %
(10 to 100) mH 1.2 % 0.42 % 0.23 % 0.36 % 5.5 % 23 %
(0.1 to 1) H 0.97 % 0.41 % 0.23 % 0.41 % 15 %
(1 to 10) H 0.94 % 0.41 % 0.27 % 2 %
(10 to 100) H 0.96 % 0.5 % 1.3 %
Inductance – Generate3
(13 to 120) µH
(0.120 01 to 1.2) mH
(1.2001 to 3.3) mH
(3.3 to 12) mH
(490 to 550) Hz
(550 to 999) Hz
1 kHz
(1.001 to 13) kHz
(13 to 17) kHz
(260 to 330) Hz
(330 to 999) Hz
1 kHz
(1.001 to 1.6) kHz
(1.6 to 2.5) kHz
(0.5 to 999) Hz
110 Hz
(111 to 800) Hz
(800 to 980) Hz
(0.5 to 109) Hz
110 Hz
(111 to 1000) Hz
(1 to 1.4) kHz
1.5 %
0.67 %
0.38 %
0.67 %
1.5 %
1.4 %
0.49 %
0.2 %
0.49 %
1.4 %
0.74 %
0.46 %
0.74 %
1.6 %
0.49 %
0.2 %
0.49 %
1.4 %
Fluke 5560A | to 100 H |
| 26 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 26 of 40
Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments
Inductance – Generate3
(cont)
(12 to 83) mH
(83 to 120) mH
(0.120 01 to 0.65) H
(0.65 to 1.2) H
(1.2001 to 5.5) H
(5.5 to 12) H
(12.001 to 30) H
(30 to 120) H
(0.1 to 99) Hz
100 Hz
(101 to 180) Hz
(180 to 230) Hz
(0.1 to 99) Hz
100 Hz
(101 to 320) Hz
(320 to 1000) Hz
(0.05 to 9.9) Hz
10 Hz
(10.1 to 30) Hz
(30 to 50) Hz
(0.05 to 9.9) Hz
10 Hz
(10.1 to 100) Hz
(100 to 170) Hz
(0.01 to 2.99) Hz
3 Hz
(3.01 to 8) Hz
(8 to 16) Hz
(0.01 to 2.99) Hz
3 Hz
(3.01 to 19) Hz
(19 to 37) Hz
(0.005 to 1.99) Hz
2 Hz
(2.01 to 4) Hz
(4 to 16) Hz
(0.005 to 1.99) Hz
2 Hz
(2.01 to 7) Hz
(7 to 14) Hz
0.53 %
0.25 %
0.53 %
1.4 %
0.49 %
0.2 %
0.49 %
1.4 %
0.61 %
0.32 %
0.6 %
1.5 %
0.52 %
0.24 %
0.52 %
1.4 %
0.68 %
0.4 %
0.68 %
1.6 %
0.57 %
0.28 %
0.57 %
1.4 %
0.89 %
0.61 %
0.89 %
1.8 %
0.61 %
0.32 %
0.6 %
1.5 %
Fluke 5560A
Inductance3 – Generate
100 mH
1 H
10 H
100 Hz to 1 kHz
100 Hz to 1 kHz
100 Hz to 1 kHz
48 µH
0.59 mH
4.2 mH
General radio
1482L
1482P
1482T | ||
| 27 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 27 of 40
Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments
Distortion3 – Measure
(-101 to 0) dB
(-130 to 0) dB
20 Hz to 20 kHz
(20 to 100) kHz
100 kHz to 3 GHz
(3 to 6.5) GHz
(6.5 to 22) GHz
(22 to 26.5) GHz
1.2 dB
2.3 dB
0.54 dB
1.8 dB
2.4 dB
3 dB
Agilent 8903B
Agilent
E4440A
Parameter/Equipment
Range CMC2, 4, 6, 7 (±) Comments
Oscilloscopes3 –
Volt
DC Signal Into 50 Ω
DC Signal Into 1 MΩ
Squarewave Into 50 Ω
Squarewave Into 1 MΩ
Edge Into 50 Ω
Leveled Sine Wave
Time Marker
± (0 to 6.6) V
± (0 to 130) V
1 mV to 6 V
p-p
1 mV to 130 Vp-p
10 Hz to 1 kHz
(1 to 100) kHz
(200 to 300) ps,
100 kHz to 2 MHz
(200 to 350) ps,
(2 to 10) MHz
5 mV to 5.5 V
50 kHz (reference)
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
4 mV to 3.5 V
(600 to 1100) MHz
5 s to 50 ms
50 ms to 1 ns
33 µV + 2 mV/V
33 µV + 0.39 mV/V
91 µV + 4.3 mV/V
0.2 mV + 0.8 mV/V
0.24 mV + 2 mV/V
82 ps
82 ps
0.33 mV + 17 mV/V
0.4 mV + 31 mV/V
0.43 mV + 36 mV/V
0.53 mV + 57 mV/V
0.58 mV + 67 mV/V
0.0021 % + (t / 1000) %
0.000 36 %
Fluke
5560A/SC1100
t = time in
seconds | -101 to 0 dB |
| 28 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 28 of 40
Parameter/Equipment
Range CMC2, 4, 6, 7 (±) Comments
Oscilloscopes3 –
(cont)
Wave Generator
1.8 mV to 2.8 V
p-p (50 Ω),
10 Hz to 100 kHz
1.8 mV to 55 V
p-p (1 MΩ),
10 Hz to 100 kHz
0.12 mV + 23 mV/V
0.12 mV + 23 mV/V
Fluke
5560A/SC1100
Oscilloscopes3 –
Voltage
DC Into 1 MΩ
DC Into 50 Ω
Squarewave Into 1 MΩ
Squarewave Into 50 Ω
Risetime – Generate
Time Marker
Level Sine Wave
± 1 mV to 200 V
± 1 mV to 5 V
40 µV + 200 V
p-p
40 µV to 5 Vp-p
150 ps
10 Hz to 2 MHz
9 ns to 83 µs
83 µs to 55 s
50 kHz to 300 MHz
(300 to 550) MHz
(0.55 to 1.1) GHz
(1.1 to 3.2) GHz
28 µV + 0.25 mV/V
29 µV + 0.25 mV/V
12 µV + 1 mV/V
12 µV + 1 mV/V
28 ps
0.000 047 %
0.000 35 %
3.3 %
3.4 %
4 %
4.4 %
Fluke 9500B
w/9530 active
head
Fluke 9500B
Fluke 9500B w/
active heads
Parameter/Range
Frequency CMC2, 4, 6, 7 (±) Comments
AC Flatness – Measure
10 Hz
100 Hz to 1 MHz
3 MHz
8 MHz
10 MHz
20 MHz
30 MHz
50 MHz
0.053 %
0.05 %
0.052 %
0.057 %
0.064 %
0.11 %
0.18 %
0.3 %
Thermal
voltage
converter,
3458A
CMC’s can be
interpolated for
frequencies that
fall between
cardinal points. | ||
| 29 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 29 of 40
Parameter/Equipment Range CMC2 (±) Comments
Electrical Calibration of
RTDs3 – Measure
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
Ni 120, 120 Ω
(-200 to 80) °C
(-80 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-80 to 260) °C
0.019 °C
0.023 °C
0.027 °C
0.031 °C
0.038 °C
0.048 °C
0.018 °C
0.018 °C
0.02 °C
0.024 °C
0.029 °C
0.038 °C
0.017 °C
0.018 °C
0.019 °C
0.019 °C
0.025 °C
0.03 °C
0.036 °C
0.043 °C
0.054 °C
0.057 °C
0.061 °C
0.061 °C
0.071 °C
0.073 °C
0.09 °C
0.029 °C
0.029 °C
0.036 °C
0.041 °C
0.049 °C
0.02 °C
0.02 °C
0.027 °C
0.03 °C
0.038 °C
0.0097 °C
Fluke 7526A | ||
| 30 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 30 of 40
Parameter/Equipment Range CMC2 (±) Comments
Electrical Calibration of
RTDs3 – Measure (cont)
Cu 427, 10 Ω
YSI 400
(-100 to 260) °C
(15 to 50) °C
0.11 °C
0.0071 °C
Fluke 7526A
Electrical Calibration of
RTDs3 – Generate
PT 385, 100 Ω
PT 3926, 100 Ω
PT 3916, 100 Ω
PT 385, 200 Ω
PT 385, 500 Ω
PT 385, 1000 Ω
Ni 120, 120 Ω
Cu 427, 10 Ω
YSI 400
(-200 to 800) °C
(-200 to 630) °C
(-200 to 630) °C
(-200 to 400) °C
(400 to 630) °C
(-200 to 630) °C
(-200 to 630) °C
(-80 to 260) °C
(-100 to 260) °C
(15 to 50) °C
0.052 °C
0.052 °C
0.052 °C
0.4 °C
0.5 °C
0.17 °C
0.091 °C
0.021 °C
0.38 °C
0.009 °C
Fluke 7526A
Thermocouple3 – Indicating
Systems & Measure
Type B
Type C
Type E
(600 to 800) °C
(800 to 1550) °C
(1550 to 1820) °C
(0 to 1000) °C
(1000 to 1800) °C
(1800 to 2000) °C
(2000 to 2316) °C
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 600) °C
(600 to 1000) °C
0.35 °C
0.28 °C
0.23 °C
0.16 °C
0.23 °C
0.27 °C
0.36 °C
0.25 °C
0.12 °C
0.091 °C
0.082 °C
0.1 °C
Fluke 7526A | ||
| 31 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 31 of 40
Parameter/Equipment Range CMC2 (±)
Comments
Thermocouple3 – Indicating
Systems & Measure (cont)
Type J
Type K
Type L
Type N
Type R
Type S
Type T
Type U
(-210 to -100) °C
(-100 to 800) °C
(800 to 1200) °C
(-250 to -200) °C
(-200 to -100) °C
(-100 to 500) °C
(500 to 800) °C
(800 to 1372) °C
(-200 to -100) °C
(-100 to 900) °C
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 100) °C
(100 to 800) °C
(800 to 1300) °C
(-50 to -25) °C
(-25 to 0) °C
(0 to 100) °C
(100 to 400) °C
(400 to 600) °C
(600 to 1000) °C
(1000 to 1600) °C
(1600 to 1767) °C
(-50 to -25) °C
(-25 to 0) °C
(0 to 100) °C
(100 to 400) °C
(400 to 600) °C
(600 to 1000) °C
(1000 to 1600) °C
(1600 to 1767) °C
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 200) °C
(200 to 400) °C
(-200 to 0) °C
(0 to 200) °C
(200 to 600) °C
0.14 °C
0.091 °C
0.11 °C
0.46 °C
0.16 °C
0.1 °C
0.1 °C
0.14 °C
0.1 °C
0.092 °C
0.73 °C
0.23 °C
0.12 °C
0.11 °C
0.1 °C
0.13 °C
0.55 °C
0.45 °C
0.39 °C
0.28 °C
0.22 °C
0.21 °C
0.2 °C
0.24 °C
0.51 °C
0.43 °C
0.38 °C
0.29 °C
0.23 °C
0.22 °C
0.22 °C
0.27 °C
0.35 °C
0.16 °C
0.14 °C
0.12 °C
0.12 °C
0.23 °C
0.1 °C
0.1 °C
Fluke 7526A | ||
| 32 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 32 of 40
V. Electrical – RF/Microwave
Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments
Power Meter3 –
Power Reference
@ 50 MHz
Power Accuracy
1 mW
3 µW to 100 mW
0.45 %
0.29 %
432A w/ 478A,
3458A
11683A
range calibrator
Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments
Amplitude Modulation3 –
Measure
(5 to 99) % Depth
(5 to 20) % Depth
(20 to 99) % Depth
(5 to 20) % Depth
(20 to 99) % Depth
100 kHz to 10 MHz
10 MHz to 3 GHz
(3 to 26.5) GHz
0.86 % of depth
2.6 % of depth
0.78 % of depth
4.6 % of depth
1.7 % of depth
Agilent E4440A
Frequency Modulation3 –
Measure
Modulation rate:
20 Hz to 10 kHz
Deviation:
200 Hz to 40 kHz
Modulation rate:
50 Hz to 200 kHz
Deviation:
250 Hz to 400 kHz
250 kHz to 10 MHz
10 MHz to 6.6 GHz
(6.6 to 13.2) GHz
(13.2 to 26.5) GHz
1.5 %
1.5 %
2.5 %
3.8 %
Agilent E4440A | ||
| 33 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 33 of 40
Parameter/Range
Frequency CMC2, 4, 6, 7 (±) Comments
Phase Modulation3 –
Measure
(0.3 to ≤ 0.7) rad
> 0.7 rad
(0.6 to ≤ 2.0) rad
2.0 rad
(1.2 to ≤ 4.0) rad
> 4.0 rad
100 kHz to 6.6 GHz
(6.6 to 13.2) GHz
(13.2 to 26.5) GHz
3 %
1.1 %
3 %
1.1 %
3 %
1.1 %
Agilent E4440A
Relative Power3 – Measure
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -120) dB
(-120 to -130) dB
100 kHz to 26.5 GHz
0.031 dB
0.035 dB
0.039 dB
0.058 dB
0.06 dB
0.064 dB
0.077 dB
0.082 dB
0.086 dB
0.096 dB
0.1 dB
0.11 dB
0.12 dB
Agilent E4440A
microwave measuring
receiver system
Attenuation – Measure3
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -120) dB
(-120 to -127) dB
10 MHz to 26.5 GHz
0.039 dB
0.042 dB
0.045 dB
0.062 dB
0.064 dB
0.068 dB
0.081 dB
0.085 dB
0.089 dB
0.099 dB
0.11 dB
0.11 dB
0.13 dB
Agilent E4440A
microwave measuring
receiver system | ||
| 34 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 34 of 40
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
Attenuation – Generate3
(1 to 11) dB
(12 to 20) dB
(21 to 60) dB
(61 to 80) dB
81 dB
(1 to 11) dB
(12 to 30) dB
(31 to 81) dB
DC to 12.4 GHz
(12.4 to 40) GHz
0.11 dB
0.14 dB
0.15 dB
0.16 dB
0.17 dB
0.35 dB
0.41 dB
0.42 dB
Keysight 84907K,
84904K
Displayed Average Noise
Level
3
(-165 to -50) dBm
9 kHz to 4 GHz
(4 to 12.4) GHz
(12.4 to 18) GHz
0.34 dB
0.65 dB
1.5 dB
50 Ω termination
Absolute Power3 – Measure
(+10 to +20) dBm
(-60 to < +10) dBm
(+10 to +20) dBm
(-10 to 0) dBm
(-60 to -10) dBm
50 MHz to 12 GHz
(12 to 18) GHz
(18 to 26.5) GHz
50 MHz to 18 GHz
(18 to 26.5) GHz
9 kHz to 6 GHz
9 kHz to 2 GHz
9 kHz to 6 GHz
5.3 %
5.4 %
6 %
3.7 %
4.6 %
2.6 %
3.1 %
3.7 %
N1913A power meter
with:
E4413A
E9304A | ||
| 35 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 35 of 40
Parameter/Range Frequency CMC2, 6, 7 (±) Comments
Single Side-Band
(SSB) Phase
Noise3 – Measure
Carrier: 1 MHz to
26.5 GHz
At offsets:
10 Hz
100 Hz
1 kHz
10 kHz
20 kHz
100 kHz
1 MHz
10 MHz
2.7 dB
2.7 dB
2.5 dB
2.4 dB
2.4 dB
2.4 dB
2.4 dB
2.4 dB
Agilent E4440A
option 226 (see below)
Lowest measurement range is determined by the E4440A local oscillator’s interaction with the unit
under test. Values stated below are informational only & serve as a guide for typical system sensitivity
performance. Actual sensitivity performance may be better than what is stated.
Up to 600 MHz
601 MHz to 10.1 GHz
(10.3 to 26.5) GHz
10 Hz offset -102 dBc/Hz -84 dBc/Hz -76 dBc/Hz
100 Hz offset -102 dBc/Hz -84 dBc/Hz -76 dBc/Hz
1 kHz offset -114 dBc/Hz -104 dBc/Hz -95 dBc/Hz
10 kHz offset -120 dBc/Hz -114 dBc/Hz -105 dBc/Hz
100 kHz offset -125 dBc/Hz -120 dBc/Hz -120 dBc/Hz
1 MHz offset -150 dBc/Hz -145 dBc/Hz -158 dBc/Hz
10 MHz offset -158 dBc/Hz -150 dBc/Hz -140 dBc/Hz
VI. Mechanical
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Balances3
Up to 20 kg
Matrix value x R
Class 1 up to 20 kg
Mass Applied
Unit Under Test Resolution
0.0001 g 0.001 g 0.01 g 0.1 g 1 g 10 g
Up to 200 mg 0.83
500 mg to 5 g 0.91
10 g 1.0
20 g 1.2
50 g 1.7
100 g 3.1 0.87 0.82
200 g 6.1 1.0
500 g 1.7
1 kg 3.1 0.87 | to 20 kg |
| 36 | EURAMET CG-18 | - | to 25000 lbf |
| 37 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 37 of 40
Parameter/Equipment Range CMC2, 4, 5 (±) Comments
Pressure3 – Measure
& Generate
Vacuum
Pneumatic
Hydraulic
(0.1 to 1000) Torr
(-30 to 30) inH
2O
(-13 to 30) psig
(-6 to 6) psig
Up to 300 psig
Up to 1000 psig
(8 to 17) psia
(-12 to 625) psig
(625 to 1250) psig
(-12 to 1250) psig
(1250 to 2500) psig
(-12 to 2500) psig
(2500 to 5000) psig
(8 to 17) psia
(-14 to 83) psig
(83 to 150) psig
(-14 to 758) psig
(758 to 1500) psig
(0 to 2) inH
2O
(-14 to 15) psig
(0 to 25) inH2O
(0 to 10) inH
2O
(0 to 30) psig
(0 to 100) psig
(0 to 500) psig
(0 to 3000) psig
(10 000 to 15 000)
psi
0.6 Torr + 0.15 %
0.0033 inH
2O + 0.013 % x
|pressure|
0.01 psi
0.0016 psi + 0.011 % x
|pressure|
0.01 %
0.012 %
0.01 %
0.063 psi
0.01 %
0.13 psi
0.01 %
0.25 psi
0.01 %
0.0019 psi + 0.000 23 psi/psi
0.019 psi
0.019 psi + 000 002 psi/psi
0.18 psi
0.18 psi + 0.000 23 psi/psi
0.0014 inH
2O
0.0095 psi
0.018 inH2O
0.032 inH
2O
0.013 psi
0.045 psi
0.24 psi
1.4 psi
18 psi
Teledyne HVG-2020A
Fluke 6270A w/:
PM500-BG7K
PM200-BG200K
PM500-BG40K
PM600-A2M
PM600-A7M
Mensor CPC8000 w/:
Barometric sensor
1250 psi sensor
2500 psi sensor
5000 psi sensor
Mensor CPC4000 w/:
Barometric sensor
150 psi sensor
1500 psi sensor
Ashcroft ATE-2 w/:
AM2-1
AM2-2
HQS-1
Fluke 750P01
Fluke 750P05
Fluke 750P06
Fluke 750P07
Fluke 750P29
Additel 680-15K | ||
| 38 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 38 of 40
VII. Thermodynamics
Parameter/Equipment Range CMC2, 4, 5, 6, 9, 10 (±) Comments
Temperature3 – Measure
(-196 to 660) °C
0.017 °C + 0.000 028 x
ΔTChange from -200 °C
Fluke 1529 w/5609
PRT
Temperature3 –
Measuring Equipment
-196 °C
(-45 to 140) °C
(50 to 660) °C
0.017 °C
0.031 °C
0.049 °C + 0.000 14 x
ΔT
Change from 50 °C
Fluke 1529 & 5609
PRT w/:
LN2
Fluke 9170 dry well
Fluke 9144 dry well
Infrared Temperature –
Measuring Equipment
3
(-15 to -12) °C
(-12 to -8) °C
(-8 to -4) °C
(-4 to 0) °C
(0 to 120) °C
(35 to 500) °C
0.51 °C
0.5 °C
0.49 °C
0.48 °C
0.6 °C + 0.0017 °C/°C
0.54 °C + ΔTChange from 35 °C x
0.0042 °C
Hart 4180
Hart 4181
Emissivity = 0.95
Wavelength
(8 to 14) µm
Relative Humidity –
Measuring Equipment
(10 to 95) % RH
0.14 % RH + 0.007
%RH/%RH
RH Systems CGS-
240
Dew Point – Measuring
Equipment
(-25 to 70) °C
0.15 °C
RH Systems CGS-
240
Relative Humidity3 –
Measure
(10 to 90) % RH
(90 to 95) % RH
1.3 % RH
2.1 % RH
Vaisala MI70 w/
HMP77/HMP76 | -196 to 660 °C |
| 39 | NIST 960-12 | - | See scope document |
| 40 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7598.01) Revised 10/28/2025 Page 40 of 40
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches;
D is the numerical value of the nominal diameter of the device measured in inches; Di is the numerical
value of the nominal diagonal of the plate measured in feet; R is the numerical value of the resolution of
the device in its respective units; F is the applied frequency in kHz; and percentages are percentage of
reading unless otherwise indicated.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 CMC components that can be reasonably attributed to the Unit Under Test have not been utilized in the
calculation of the CMC value for this measurement parameter.
7 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
8 This scope meets A2LA’s P112 Flexible Scope Policy.
9 In the statement of CMC, T = greater of 1 °F or ABS value of gage environmental temperature from 68
°F.
10 In the statement of CMC, T = greater of 4 °F or ABS value of gage environmental temperature from 68
°F. | ||
| 41 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Technical Maintenance, Inc. - MELBOURNEMelbourne, FL · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- FLORIDA METROLOGYPort St. Lucie, FL · ~91 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Kimball ElectronicWinter Park, FL · ~93 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- LDS Vacuum ProductsLongwood, FL · ~100 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Applied Technical Services , LLC.Sanford, FL · ~102 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.