Kimball Electronic

6801 University Blvd., Suite #4, 32792, Winter Park, FL, United States

Visit website
A2LA 2178.03ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
8
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 8 scope lines.

A2LA certificate 2178.03 · 8 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2178.03) Revised 7/30/2025 Page 2 of 7 Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Current – Generate (0.3 to 3.29) mA (3.3 to 32.9) mA (33 to 329.9) mA 330 mA to 1 A (1 to 10) A 0.013 % + 0.052 µA 0.010 % + 0.25 µA 0.010 % + 3.3 µA 0.031 % + 43 µA 0.069 % + 250 µA Fluke 5500A DC Current – Measure (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A 22 µA/A + 0.83 nA 18 µA/A + 0.017 µA 18 µA/A + 0.17 µA 28 µA/A + 2.3 µA 0.010 % + 44 µA HP 3458A Electrical Calibration of Thermocouple Indicating Equipment – Type J Type K Type T (-210 to -100) oC (-100 to -30) oC (-30 to 150) oC (150 to 760) oC (-200 to -100) oC (-100 to -25) oC (-25 to 120) oC (120 to 1000) oC (1000 to 1372) oC (-250 to -150) oC (-150 to 0) oC (0 to 120) oC (120 to 400) oC 0.29 oC 0.19 oC 0.17 oC 0.20 oC 0.34 oC 0.21 oC 0.19 oC 0.28 oC 0.41 oC 0.64 oC 0.26 oC 0.19 oC 0.17 oC Fluke 5500A Resistance – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (330 to 1100) Ω (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (330 to 1100) kΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ 0.012 % + 8 mΩ 0.012 % + 15 mΩ 0.009 % + 15 mΩ 0.009 % + 15 mΩ 0.010 % + 56 mΩ 0.009 % + 60 mΩ 0.009 % + 600 mΩ 0.009 % + 600 mΩ 0.011 % + 6 Ω 0.012 % + 6 Ω 0.015 % + 55 Ω 0.015 % + 55 Ω 0.06 % + 540 Ω 0.10 % + 540 Ω 0.50 % + 5.1 kΩ 0.50 % + 16 kΩ Fluke 5500A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2178.03) Revised 7/30/2025 Page 3 of 7 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Resistance – Measure (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ 0.0010 % + 0.6 mΩ 0.0011 % + 2.4 mΩ 0.0014 % + 5.0 mΩ 0.0018 % + 9.3 mΩ 0.0018 % + 93 mΩ 0.0023 % + 3.8 Ω 0.008 % + 97 Ω 0.10 % + 690 Ω HP 3458A Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate (1 to 33) mV (33 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1000) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.35 % + 20 µV 0.15 % + 20 µV 0.21 % + 20 µV 0.25 % + 20 µV 0.35 % + 33 µV 1.0 % + 60 µV 0.25 % + 50 µV 0.05 % + 21 µV 0.10 % + 20 µV 0.16 % + 40 µV 0.24 % + 170 µV 0.70 % + 330 µV 0.15 % + 250 µV 0.03 % + 60 µV 0.08 % + 60 µV 0.12 % + 300 µV 0.24 % + 1700 µV 0.15 % + 2600 µV 0.04 % + 580 µV 0.08 % + 2.6 mV 0.19 % + 5 mV 0.24 % + 17 mV 0.05 % + 6.5 mV 0.08 % + 15 mV 0.09 % + 33 mV 0.05 % + 69 mV 0.21 % + 76 mV 0.21 % + 470 mV Fluke 5500A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2178.03) Revised 7/30/2025 Page 4 of 7 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Measure (1 to 10) mV (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 700) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 40 Hz to 1 kHz 0.022 % + 4.5 µV 0.011 % + 3.2 µV 0.020 % + 3.1 µV 0.050 % + 9.3 µV 0.041 % + 11 µV 3.3 % + 75 µV 0.009 % + 4.7 µV 0.012 % + 2.8 µV 0.018 % + 2.8 µV 0.044 % + 5.9 µV 0.085 % + 4.9 µV 0.27 % + 50 µV 0.008 % + 39 µV 0.008 % + 21 µV 0.015 % + 21 µV 0.031 % + 32 µV 0.082 % + 25 µV 0.31 % + 0.1 mV 0.008 % + 0.39 mV 0.008 % + 0.19 mV 0.016 % + 0.19 mV 0.033 % + 0.19 mV 0.082 % + 0.21 mV 0.023 % + 1.8 mV 0.023 % + 1.8 mV 0.038 % + 1.9 mV 0.13 % + 1.6 mV 0.042 % + 20 mV HP 3458A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2178.03) Revised 7/30/2025 Page 5 of 7 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate (30 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1) A (1 to 10) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz 0.25 % + 0.15 µA 0.13 % + 0.15 µA 0.13 % + 0.25 µA 0.40 % + 0.15 µA 1.3 % + 0.15 µA 0.20 % + 0.3 µA 0.10 % + 0.3 µA 0.10 % + 0.3 µA 0.20 % + 0.3 µA 0.60 % + 0.3 µA 0.20 % + 3 µA 0.10 % + 3 µA 0.09 % + 3 µA 0.20 % + 3 µA 0.60 % + 3 µA 0.20 % + 30 µA 0.10 % + 30 µA 0.09 % + 30 µA 0.20 % + 30 µA 0.22 % + 0.25 mA 0.13 % + 0.21 mA 0.81 % + 0.10 mA 0.07 % + 2.1 mA 0.10 % + 2.1 mA 0.33 % + 2.1 mA Fluke 5500A
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2178.03) Revised 7/30/2025 Page 6 of 7 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Measure Up to 100 µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz 0.40 % + 0.04 µA 0.15 % + 0.03 µA 0.06 % + 0.03 µA 0.06 % + 0.03 µA 0.41 % + 0.21 µA 0.15 % + 0.22 µA 0.06 % + 0.20 µA 0.03 % + 0.20 µA 0.40 % + 2 µA 0.15 % + 2 µA 0.06 % + 2 µA 0.03 % + 2 µA 0.40 % + 20 µA 0.15 % + 20 µA 0.06 % + 20 µA 0.03 % + 20 µA 0.40 % + 200 µA 0.16 % + 200 µA 0.08 % + 200 µA 0.10 % + 200 µA HP 3458A Parameter/Equipment Range CMC2, 4 (±) Comments Capacitance – Generate (0.5 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF 330 µF to 1.1 mF 0.45 % + 11 pF 0.51 % + 10 pF 0.50 % + 11 pF 0.26 % + 100 pF 0.26 % + 100 pF 0.26 % + 290 pF 0.23 % + 1.1 nF 0.36 % + 3 nF 0.36 % + 9.9 nF 0.41 % + 30 nF 0.79 % + 13 nF 0.67 % + 490 nF 1.0 % + 370 nF Fluke 5500A
to 1 mF
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2178.03) Revised 7/30/2025 Page 7 of 7 III. Mechanical Parameter/Equipment Range CMC2, 6 (±) Comments Pressure Gauges & Transducers (0 to 400) psi (400 to 4000) psi (2000 to 15 000) psi 0.005 % + 0.14 psi 0.0022 % + 0.65 psi 0.11 % + 2.1 psi Mensor Crystal XP2I Torque – Measuring Equipment (0 to 50) in·lbf (30 to 400) in·lbf (100 to 1000) in·lbf (20 to 250) ft·lbf (60 to 600) ft·lbf 0.17 % + 0.11 in·lbf 0.28 % + 0.17 in·lbf 0.31 % + 0.03 in·lbf 0.26 % + 0.16 ft·lbf 0.30 % + 0.10 ft·lbf CDI 2000-400-02 CDI 2000-12-02 ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. Where ranges are not specified, the best measurement uncertainty stated is for the cardinal points only. 3 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. 4 The measurands stated are generated with the Fluke 5500A. This capability is suitable for the calibration of the devices intended to measure the stated measurand in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification. 5 The measurands stated are measured with the HP 3458A. This capability is suitable for the calibration of the devices intended to generate the measurand in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a combination of the fraction of the reading/output plus a range specification. 6 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
8ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

6801 University Blvd., Suite #4, Winter Park, FL, 32792, US