CIH Equipment Company

1806 S. Highland Avenue, 33756, Clearwater, FL, United States

Visit website
A2LA 3035.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
8
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 8 scope lines.

A2LA certificate 3035.01 · 8 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994water31 to 10000 Hz
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3035.01) Revised 08/25/2025 Page 2 of 8 Parameter/Equipment Range CMC2,3 (±) Comments Accelerometer – Voltage Sensitivity (10 to 99.9) Hz 100 Hz (100.1 to 160) Hz (160.1 to 2000) Hz (2000.1 to 5000) Hz (5000.1 to 10 000) Hz 2.3 % 2.2 % 2.3 % 2.5 % 2.5 % 2.8 % RULA accelerometer system using back-to- back calibration method Vibration Meter (Single Axis) @ 100Hz Acceleration Velocity Displacement 1 g RMS (>1 to 2) g RMS (>2 to 3) g RMS (>3 to 4) g RMS (>4 to 5) g RMS 15 mm/s RMS (>15 to 31) mm/s RMS (>13 to 47) mm/s RMS (>47 to 80) mm/s RMS 0.07 mm (>0.07 to 0.14) mm (>0.14 to 0.21) mm (>0.28 to 0.4) mm 2.3 % 2.5 % 2.8 % 2.5 % 3.5 % 2.5 % 2.2 % 2.3 % 2.5 % 3.5 % 2.3 % 2.4 % 2.5 % RULA vibration controller system using back-to-back calibration and software integration
3ISO Standard-See scope document
4-Air; air
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3035.01) Revised 08/25/2025 Page 4 of 8 Parameter/Equipment Range CMC2, 3, 5 (±) Comments Calibration of Air Sampling Pump – Air Flow (0.5 to 50) SCCM (51 to 150) SCCM (151 to 250) SCCM (251 to 350) SCCM (351 to 500) SCCM (0.1 to 0.5) SLPM (0.6 to 1.5) SLPM (1.6 to 2.5) SLPM (2.6 to 3.5) SLPM (3.6 to 5) SLPM (1 to 5) SLPM (5.1 to 10) SLPM (10.1 to 15) SLPM (15.1 to 20) SLPM (20.1 to 30) SLPM 1.4 % 1.3 % 1.3 % 2.2 % 2.1 % 0.03 SLPM 0.04 SLPM 0.06 SLPM 0.08 SLPM 0.10 SLPM 1.3 % 1.2 % 1.2 % 1.1 % 1.2 % Piston Provers – Definer 220L low flow Definer 220M medium flow Definer 220H high flow Mass Flow Meters (0.1 to 1) SLPM (1.1 to 5) SLPM (5.1 to 10) SLPM (10.1 to 15) SLPM (15.1 to 20) SLPM (1 to 10) SLPM (11 to 30) SLPM (31 to 50) SLPM (51 to 100) SLPM (101 to 150) SLPM 0.05 SLPM 0.14 SLPM 0.25 SLPM 0.37 SLPM 0.47 SLPM 0.25 SLPM 0.67 SLPM 1.2 SLPM 2.6 SLPM 3.3 SLPM Mass flow meter – TSI 4146 Mass flow meter – TSI 4043 Flow (Air) (400 to 1229) CFM (1230 to 2399) CFM (2400 to 2600) CFM 65 CFM 76 CFM 110 CFM Dwyer manometer calibrated using TSI air velocity transducer (Flow hood)
See scope document
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3035.01) Revised 08/25/2025 Page 5 of 8 III. Magnetic Quantities Parameter/Equipment Range CMC2, 5 (±) Comments Gauss Meter – Axial Probe Flat/ Transverse Probe (1 to 100) G (101 to 290) G (291 to 500) G (501 to 2000) G (2001 to 2870) G (7 to 24) G (100 to 290) G (291 to 1000) G (1001 to 5000) G (5001 to 10 000) G 6.3 G 15 G 22 G 42 G 56 G 4.2 G 16 G 20 G 83 G 87 G Reference standard Gauss meter Comparison IV. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Pressure – Measuring Equipment (Pneumatic) Vacuum Pressure (-9 to -53) inH2O (-54 to -153) inH2O (-154 to -253) inH2O (-254 to -403) inH2O (9 to 53) inH2O (54 to 153) inH2O (154 to 253) inH2O (254 to 403) inH2O 0.19 inH2O 0.14 inH2O 0.16 inH2O 0.33 inH2O 0.22 inH 2O 0.21 inH2O 0.24 inH2O 0.28 inH2O Ametek dead weight tester
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3035.01) Revised 08/25/2025 Page 6 of 8 Parameter/Equipment Range CMC2, 5 (±) Comments Force – Tension Compression (25.1 to 100) lbf (100.1 to 200) l lbf (200.1 to 250) lbf (250.1 to 500) lbf (25.1 to 100) lbf (100.1 to 200) l lbf (200.1 to 250) lbf (250.1 to 500) lbf 2.5 lbf 2.8 lbf 3.2 lbf 3.9 lbf 2.8 lbf 3.3 lbf 3.2 lbf 3.3 lbf PCE Load Cell With universal testing machine Torque – Manual Wrenches Hydraulic Wrenches (1000 to 10 000 PSI) Low Torque (21 to 50) lbf-ft (51 to 100) lbf-ft Standard Torque (51 to 125) lb-ft (126 to 250) lb-ft (>350 to 2100) lb-ft (>2100 to 4200) lb-ft (>4200 to 4400) lb-ft 0.39 lbf-ft 0.59 lbf-ft 0.56 lb-ft 0.89 lb-ft 14 lb-ft 47 lb-ft 170 lb-ft AKO AKO AWS torque system
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3035.01) Revised 08/25/2025 Page 7 of 8 V. Thermodynamics Parameter/Equipment Range CMC2, 5, 6 (±) Comments Temperature – Measuring Equipment 32 °F (33 to 67) °F (68 to 140) °F (32 to 140) °F 0.42 °F 0.44 °F 0.46 °F 0.43 °F Temp/Humidity chamber w/ Vaisala HMT 333 (E) Temp/Humidity chamber w/ Vaisala HMT 333 (H) Humidity – Measuring Equipment (25 to 49) % RH (50 to 89) % RH (90 to 95) % RH (25 to 49) % RH (50 to 89) % RH (90 to 95) % RH 1.4 % RH 3.4 % RH 3.0 % RH 1.4 % RH 2.3 % RH 2.9 % RH Humidity chamber w/ Vaisala HMT 333 (E) Humidity chamber w/ Vaisala HMT 333 (H) Temperature – Infrared (100 to 400) °F (400 to 752) °F (212 to 1000) °F (1001 to 1634) °F (3.3 + 0.0076T) °F (0.23 + 0.016T) °F (0.19 + 0.021T) °F (4.7 + 0.017T) °F Mid-temp blackbody standard High-temp blackbody standard ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentages are percentages of the reading/output, unless otherwise noted. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter
8ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205water-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1806 S. Highland Avenue, Clearwater, FL, 33756, US

27.95866, -82.77523