Kimball Electronic
8020 West 20 Ave, 33016, Hialeah, FL, United States
Visit website- Scope lines
- 14
- A2LA certificate
- 1
- Sites in our directory
- 3
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 14 scope lines.
A2LA certificate 2178.01 · 14 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 24 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2178.01) Revised 3/7/2025 Page 2 of 13
II. Electrical – DC/ Low Frequency
Parameter/Equipment
Range CMC2, 4, 5, 7 (±) Comments
DC Voltage – Generate
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
7.4 µV/V + 0.54 µV
5.0 µV/V + 0.87 µV
3.8 µV/V + 2.1 µV
3.9 µV/V + 1.4 µV
5.1 µV/V + 41 µV
6.9 µV/V + 330 µV
Fluke 5730A
DC Voltage – Measure
Up to 100 mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
13 µV/V + 0.4 µV
14 µV/V + 0.3 µV
14 µV/V + 0.5 µV
14 µV/V + 31 µV
14 µV/V + 90 µV
Fluke 8588A
DC Current – Generate
(0 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(1 to 10) A
0.0033 % + 0.002 µA
36 µA/A + 0.008 µA
37 µA/A + 0.038 µA
39 µA/A + 2.6 µA
0.008 % + 12 µA
0.069 % + 250 µA
Fluke 5730A
Fluke 5522A
DC Current – Measure
(10 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
22 µA/A + 0.83 nA
18 µA/A + 0.017 µA
18 µA/A + 0.17 µA
28 µA/A + 2.3 µA
0.010 % + 44 µA
Fluke 8588A
Resistance – Generate
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(330 to 1100) Ω
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(330 to 1100) kΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
0.012 % + 8 mΩ
0.012 % + 15 mΩ
0.009 % + 15 mΩ
0.009 % + 15 mΩ
0.010 % + 56 mΩ
0.009 % + 60 mΩ
0.009 % + 600 mΩ
0.009 % + 600 mΩ
0.011 % + 6 Ω
0.012 % + 6 Ω
0.015 % + 55 Ω
0.015 % + 55 Ω
0.06 % + 560 Ω
0.10 % + 550 Ω
0.51 % + 5.3 kΩ
0.51 % + 17 kΩ
Fluke 5522A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2178.01) Revised 3/7/2025 Page 3 of 13
Parameter/Equipment
Range CMC2, 4, 5, 7 (±) Comments
Resistance – Generate (cont)
Fixed Points
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
100 µΩ/Ω
97 µΩ/Ω
26 µΩ/Ω
25 µΩ/Ω
11 µΩ/Ω
11 µΩ/Ω
7 µΩ/Ω
11 µΩ/Ω
7 µΩ/Ω
11 µΩ/Ω
10 µΩ/Ω
12 µΩ/Ω
14 µΩ/Ω
19 µΩ/Ω
42 µΩ/Ω
51 µΩ/Ω
0.012 MΩ
Fluke 5522A
Fluke 5730A
Resistance – Measure
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
0.0010 % + 0.6 mΩ
0.0011 % + 2.4 mΩ
0.0014 % + 5.0 mΩ
0.0018 % + 9.3 mΩ
0.0018 % + 93 mΩ
0.0023 % + 3.8 Ω
0.008 % + 97 Ω
0.103 % + 690 Ω
HP 3458A
Fluke 8588A
Parameter/Equipment
Frequency CMC2, 4, 5, 7 (±) Comments
AC Voltage – Generate
(0.2 to 2.2) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
0.022 % + 4.1 µV
0.07 % + 4.4 µV
0.008 % + 4.1µV
0.019 % + 4.9 µV
0.049 % + 5.1 µV
0.1 % + 10 µV
0.14 % + 20 µV
0.26 % + 21 µV
Fluke 5730A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2178.01) Revised 3/7/2025 Page 4 of 13
Parameter/Equipment
Frequency CMC2, 4, 5, 7 (±) Comments
AC Voltage – Generate (cont)
(2.2 to 22) mV
(22 to 220) mV
220 mV to 2.2 V
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(15 to 50) Hz
50 Hz to 1 kHz
0.026 % + 4 µV
0.010 % + 4.3 µV
0.008 % + 4 µV
0.02 % + 4 µV
0.05 % + 5 µV
0.11 % + 10 µV
0.14 % + 20 µV V
0.29 % + 20 µV
0.029 % + 3.3 µV
0.011 % + 3.9 µV
0.008 % + 4.1 µV
0.013 % + 5.6 µV
0.036 % + 8.3 µV
0.067 % + 20 µV
0.14 % + 20 µV
0.29 % + 21 µV
0.025 % + 0.04 µV
0.010 % + 0.01 µV
0.006 % + 0.01 µV
0.008 % + 0.01 µV
0.007 % + 0.07 µV
0.034 % + 0.09 µV
0.1 % + 0.1 µV
0.18 % + 0.27 µV
0.025 % + 0.40 mV
0.010 % + 0.14 mV
0.006 % + 0.04 mV
0.068 % + 1 mV
0.089 % + 2 mV
0.027 % + 0.59 mV
0.10 % + 2 mV
0.17 % + 2.9 mV
0.025 % + 0.24 mV
0.010 % + 0.26 mV
0.006 % + 0.19 mV
0.008 % + 0.02 mV
0.014 % + 0.41 mV
0.09 % + 0.08 mV V
0.44 % + 0.05 mV
0.80 % + 0.09 mV
0.027 % + 7.5 mV
0.007 % + 3.1 mV
Fluke 5730A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2178.01) Revised 3/7/2025 Page 5 of 13
Parameter/Equipment
Frequency CMC2, 4, 5, 7 (±) Comments
AC Voltage – Generate (cont)
(330 to 1000) V
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.05 % + 81 mV
0.21 % + 120 mV
0.21 % + 510 mV
Fluke 5522A
AC Voltage – Measure
(1 to 10) mV
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 700) V
(1 to 40 Hz)
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40 Hz)
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40 Hz)
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40 Hz)
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
40 Hz to 1 kHz
0.022 % + 4.5 µV
0.011 % + 3.2 µV
0.020 % + 3.1 µV
0.050 % + 9.3 µV
0.041 % + 11 µV
3.3 % + 75 µV
0.009 % + 4.7 µV
0.012 % + 2.8 µV
0.018 % + 2.8 µV
0.044 % + 5.9 µV
0.085 % + 4.9 µV
0.27 % + 50 µV
0.008 % + 39 µV
0.008 % + 21 µV
0.015 % + 21 µV
0.031 % + 32 µV
0.082 % + 25 µV
0.31 % + 0.1 mV
0.008 % + 0.39 mV
0.008 % + 0.19 mV
0.016 % + 0.19 mV
0.033 % + 0.19 mV
0.082 % + 0.21 mV
0.023 % + 1.8 mV
0.023 % + 1.8 mV
0.038 % + 1.9 mV
0.13 % + 1.6 mV
0.042 % + 20 mV
HP 3458A
Fluke 8588A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2178.01) Revised 3/7/2025 Page 6 of 13
Parameter/Equipment
Frequency CMC2, 4, 5, 7 (±) Comments
AC Current – Generate
(0 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(1 to 10) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
.
0.024 % + 22 nA
0.016 % + 12 nA
0.011 % + 8.4 nA
0.028 % + 20 nA
0.11 % + 66 nA
0.028 % + 13 nA
0.018 % + 7 nA
0.013 % + 5.3 nA
0.025 % + 27 nA
0.14 % + 4.8 nA
0.027 % + 370 nA
0.017 % + 350 nA
0.011 % + 340 nA
0.021 % + 540 nA
0.11 % + 5 µA
0.026 % + 4.2 µA
0.017 % + 3.3 µA
0.012 % + 2.3 µA
0.021 % + 3.4 µA
0.11 % + 9.7 µA
0.025 % + 34 µA
0.046 % + 78 µA
0.71 % + 150 µA
0.07 % + 2.1 mA
0.10 % + 2.1 mA
0.33 % + 2.1 mA
Fluke 5730A
Fluke 5730A
Fluke 5522A | ||
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2178.01) Revised 3/7/2025 Page 7 of 13
Parameter/Equipment
Frequency CMC2, 4, 5, 7 (±) Comments
AC Current – Measure
Up to 100 µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
0.40 % + 0.04 µA
0.15 % + 0.03 µA
0.06 % + 0.03 µA
0.06 % + 0.03 µA
0.41 % + 0.21 µA
0.15 % + 0.22 µA
0.06 % + 0.20 µA
0.03 % + 0.20 µA
0.40 % + 2 µA
0.15 % + 2 µA
0.06 % + 2 µA
0.03 % + 2 µA
0.40 % + 20 µA
0.15 % + 20 µA
0.06 % + 20 µA
0.03 % + 20 µA
0.40 % + 200 µA
0.16 % + 200 µA
0.08 % + 200 µA
0.10 % + 200 µA
HP 3458A
Fluke 8588A
Parameter/Equipment
Range CMC2, 4, 5, 7 (±) Comments
Capacitance – Generate @
1 kHz
(0.5 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
330 µF to 1.1 mF
0.45 % + 11 pF
0.51 % + 10 pF
0.50 % + 11 pF
0.26 % + 100 pF
0.26 % + 100 pF
0.26 % + 290 pF
0.23 % + 1.1 nF
0.36 % + 3 nF
0.36 % + 9.9 nF
0.41 % + 30 nF
0.79 % + 13 nF
0.67 % + 490 nF
1.0 % + 370 nF
Fluke 5522A | to 1.1 mF |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2178.01) Revised 3/7/2025 Page 8 of 13
Parameter/Equipment
Range CMC2, 4, 5, 7 (±) Comments
Electrical Calibration of
Thermocouple Indicating
Equipment –
Type B
Type C
Type E
Type J
Type K
(600 to 800)
oC
(800 to 1000) oC
(1000 to 1550) oC
(1550 to 1820) oC
(0 to 150)
oC
(150 to 650) oC
(650 to 1000) oC
(1000 to 1800) oC
(1800 to 2316) oC
(-250 to -100)
oC
(-100 to -25) oC
(-25 to 350) oC
(350 to 650) oC
(650 to 1000) oC
(-210 to -100)
oC
(-100 to -30) oC
(-30 to 150) oC
(150 to 760) oC
(760 to 1200) oC
(-200 to -100)
oC
(-100 to -25) oC
(-25 to 120) oC
(120 to 1000) oC
(1000 to 1372) oC
0.47
oC
0.43 oC
0.33 oC
0.36 oC
0.32
oC
0.30 oC
0.34 oC
0.52 oC
0.86 oC
0.53
oC
0.19 oC
0.18 oC
0.20 oC
0.26 oC
0.29
oC
0.19 oC
0.17 oC
0.20 oC
0.26 oC
0.34
oC
0.21 oC
0.19 oC
0.28 oC
0.41 oC
Fluke 5522A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2178.01) Revised 3/7/2025 Page 9 of 13
Parameter/Equipment
Range CMC2, 4, 5, 7 (±) Comments
Electrical Calibration
of Thermocouple
Indicating Equipment –
Type N
Type R
Type S
Type T
(-200 to -100)
oC
(-100 to -25) oC
(-25 to 120) oC
(120 to 410) oC
(410 to 1300) oC
(0 to 250)
oC
(250 to 400) oC
(400 to 1000) oC
(1000 to 1767) oC
(0 to 250) oC
(250 to 1000) oC
(1000 to 1400) oC
(1400 to 1767) oC
(-250 to -150)
oC
(-150 to 0) oC
(0 to 120) oC
(120 to 400) oC
0.41
oC
0.24 oC
0.22 oC
0.21 oC
0.29 oC
0.58 oC
0.36 oC
0.35 oC
0.41 oC
0.48 oC
0.37 oC
0.38 oC
0.47 oC
0.64
oC
0.26 oC
0.19 oC
0.17 oC
Fluke 5522A
III. Electrical – RF/Microwave
Parameter/Range
Frequency CMC2, 5, 7 (±) Comments
Amplitude Modulation –
Measure
Rate: 50 Hz to 10 kHz
Depths: (5 to 99) %
Rate: 20 Hz to 10 kHz
Depths: (5 to 99) %
Rate: 50 Hz to 50 kHz
Depths: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depths: (5 to 99) %
150 kHz to 10 MHz
150 kHz to 10 MHz
(10 to 1300) MHz
(10 to 1300) MHz
2 % + 0.17 % FS
3.0 % + 0.16 % FS
1.0 % + 0.18 % FS
3 % + 0.16 % FS
R&S FMR measuring
receiver | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2178.01) Revised 3/7/2025 Page 10 of 13
Parameter/Equipment
Range CMC2, 6, 7 (±) Comments
Frequency Modulation –
Measure
Rate: 20 Hz to 10 kHz
Dev: ≤ 40 kHz Peak
Rate: 50 Hz to 100 kHz
Dev: ≤ 400 kHz Peak
Rate: 20 Hz to 200 kHz
Dev: ≤ 400 kHz Peak
250 kHz to 10 MHz
(10 to 1300) MHz
(10 to 1300) MHz
2.0 % + 0.12 % FS
0.97 % + 0.13 % FS
5.0 % + 0.11 % FS
R&S FMR measuring
receiver
Distortion – Measure
(Fixed Points)
1 kHz
20 kHz
100 kHz
2.3 dB
3.0 dB
3.0 dB
R&S FMR measuring
receiver
IV. Mechanical
Parameter/Equipment
Range CMC2, 6, 7 (±) Comments
Pneumatic Pressure
Gauges and Transducers
Air Data Test Sets
and Pitot Testers
Hydraulic Pressure
Gauge
(0 up to 20 psig
(20 to 50) psig
(50 to 100) psig
(100 to 1000) psig
(1000 to 2500) psig
(2500 to 5000) psig
Up to 50 psig
(50 to 10000 psig
(5000 to 7500) psig
(1000 to 6000) psig
(3000 to 15 000)
psig
(0.5 to 32) in·Hg
(32 to 68) in·Hg
Up to 10 000 psig
0.016 psig
0.036 psig
0.086 psig
0.65 psig
2.6 psig
4.3 psig
0.00015 % + 0.0013 psig
0.00017 % + 0.0051 psig
4.4 psig
0.012 % + 0.1 psig
0.015 %
(0.5 to 32) in·Hg
(32 to 68) in·Hg
0.061 %
Eaton UPS 3000
Ruska 2468A
Heise HQS
Fluke PPCH-G
Fluke Ruska 7750i
Ruska 2468A
Crystal digital
pressure gauge | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2178.01) Revised 3/7/2025 Page 11 of 13
Parameter/Equipment
Range CMC2, 6, 7 (±) Comments
Torque Measuring
Equipment
(0 to 2000) ft·lbf
(5 to 50) in·oz
(15 to 200) in·oz
(0 to 50) in·lbf
(30 to 400) in·lbf
(100 to 1000) in·lbf
(20 to 250) ft·lbf
(60 to 600) ft·lbf
1.0 % Full scale
0.31 %
0.32 %
0.17 % + 0.11 in·lbf
0.28 % + 0.17 in·lbf
0.31 % + 0.03 in·lbf
0.26 % + 0.16 ft·lbf
0.30 % + 0.10 ft·lbf
AKO TSD 4011
CDI 2000-4-02
CDI 2000-5-02
CDI 2000-400-02
CDI 2000-12-02
Force – Measuring
Equipment
Compression
Tension
Up to 500 lbf
(500 to 1000) lbf
(1000 to 5000) lbf
(5000 to 50 000) lbf
Up to 500 lbf
(500 to 1000) lbf
(1000 to 2000) lbf
0.05 lbf
0.12 lbf
0.60 lbf
6 lbf
0.05 lbf
0.12 lbf
0.60 lbf
Load cells
Load cells
Scales & Balances
Up to 1 g
(1 to 10) g
(10 to 20) g
(20 to 50) g
(50 to 100) g
(100 to 200) g
(200 to 300) g
(300 to 500) g
(500 to 1000) g
(1 to 2) kg
(2 to 4) kg
(4 to 5) kg
(5 to 10) kg
Up to 2 lb
(2 to 5) lb
(5 to 10) lb
(10 to 20) lb
(20 to 250 lb
(25 to 50) lb
(50 to 100) lb
(100 to 5000 lb
0.04 mg
0.06 mg
0.07 mg
0.14 mg
0.29 mg
0.58 mg
0.88 mg
1.4 mg
2.9 mg
6.1 mg
12 mg
14 mg
29 mg
0.000 24 lb
0.001 lb
0.0011 lb
0.0023 lb
0.0028 lb
0.0062 lb
0.006 lb
0.02 lb
ASTM Class 1
Weights
Class F weights | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2178.01) Revised 3/7/2025 Page 12 of 13
V. Thermodynamics
Parameter/Equipment
Range CMC2, 6, 7 (±) Comments
Temperature –
Measuring Equipment
(-25 to 0) oC
(0 to 50) oC
(50 to 100) oC
(100 to140) oC
(50 to 200) oC
(200 to 420) oC
(420 to 550) oC
(-45 to 140) oC
(18 to 28) oC
0.038 oC
0.040 oC
0.046 oC
0.046 oC
0.080 oC
0.098 oC
0.13 oC
0.080 oC
0.22 oC
Fluke 9142
Fluke 7109A
Fluke 9144
Fluke 9170
Fluke 5128A
Humidity – Measure
(7 to 80) % RH
(80 to 95) % RH
0.57 % RH
0.64 % RH
Fluke 5128A
VI. Time and Frequency
Parameter/Equipment
Range CMC2, 7 (±) Comments
RPM – Measuring
Equipment
Non-Contact
(1 to 200 000) RPM
0.0019 % + 0.27 RPM
Fluke 5522A w LED
__________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 %level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laborato ry
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. Where ranges are not specified, the best measurement uncertainty
stated is for the cardinal points only.
3 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2178.01) Revised 3/7/2025 Page 13 of 13
4 The measurands stated are generated with the Fluke 5730A and Fluke 5522A. This capability is suitable
for the calibration of the devices intended to measure the stated measurand in the ranges indicated. CMC
is read as output plus one-year floor specifications where defined. CMCs are expressed as either a specific
value that covers the full range or as a combination of the percent or portion of the reading plus a fixed
floor specification.
5 The stated measured value are determine using the indicated instrument (see comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measurand in the ranges
indicated. CMCs are expressed as either a specific value that covers the full range or as a combination of
the percent or portion of the reading plus a fixed floor specification.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibration instruments that measure or generate the values in the range indicated
for the listed measurement parameter.
7 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
8 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 14 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
2 other sites in this organization
Labs with overlapping accredited scope in United States
- M & M MetrologyDeerfield Beach, FL · ~58 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Miami, FLBoca Raton, FL · ~62 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- RTX (FL) Corporation dba Pratt & Whitney Calibration ServicesJupiter, FL · ~125 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- FLORIDA METROLOGYPort St. Lucie, FL · ~163 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- TrescalMelbourne, FL · ~252 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.